Vessel Wall Imaging in 1.5 T MRI Using Deep Learning Reconstruction: Prospective Evaluation of Interchangeability With Standard 3 T MRI.

IF 7.9 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Arwed Elias Michael, Haidara Almansour, Roman Paul, Dominik Nickel, Ralph Strecker, Alexander Brockmann, Vanessa Schoeffling, Sebastian Altmann, Ahmed E Othman
{"title":"Vessel Wall Imaging in 1.5 T MRI Using Deep Learning Reconstruction: Prospective Evaluation of Interchangeability With Standard 3 T MRI.","authors":"Arwed Elias Michael, Haidara Almansour, Roman Paul, Dominik Nickel, Ralph Strecker, Alexander Brockmann, Vanessa Schoeffling, Sebastian Altmann, Ahmed E Othman","doi":"10.1097/RLI.0000000000001290","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Vessel wall magnetic resonance imaging is important in the diagnosis of intracranial vascular diseases. Until now, adequate clinical implementation has required the use of 3 T scanners, which limits wider availability. This study aims to evaluate the interchangeability of a 3D turbo spin echo sequence with variable flip angle MRI sequence (T1 3D Sampling Perfection with Application optimized Contrast using different flip angle Evolution, SPACE) with deep learning image reconstruction for a 1.5 T scanner, with an established sequence (T1 3D SPACE) for a 3 T scanner. In addition, image quality parameters and diagnostic confidence are to be compared.</p><p><strong>Materials and methods: </strong>Patients were prospectively examined using a T1-weighted turbo spin echo with variable flip angle at 3 T and a similar newly developed sequence with deep learning-based image reconstruction at 1.5 T. The images were read by 3 experienced radiologists regarding the presence of pathologic enhancement of the vessel wall for the interchangeability analysis. Image quality and diagnostic confidence were evaluated using 5-point Likert scales. Interreader and intrareader reliability were calculated for all parameters.</p><p><strong>Results: </strong>A total of 50 participants (42.6 ± 21.2 y, 26 males) were included. Regarding the presence of pathologic vessel wall enhancement, there was a high interreader agreement [Fleiss kappa = 0.72 (95% CI: 0.62; 0.81) for 1.5T, 0.78 (0.69; 0.88) for 3 T]. The sequences at 1.5 T and 3 T were interchangeable (IEI = 0.008). Image quality at 1.5 T was diagnostic in all cases, but rated superior at 3 T (P < 0.001). Diagnostic confidence was also slightly but significantly higher at 3 T (P < 0.001).</p><p><strong>Conclusions: </strong>The utilization of deep learning reconstruction enables vessel wall imaging in 1.5 T MRI. This new MRI sequence was interchangeable with established sequences at 3 T for the detection of pathologic vessel wall enhancement. This development could significantly improve the availability of vessel wall imaging in the clinical routine.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2026-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001290","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Vessel wall magnetic resonance imaging is important in the diagnosis of intracranial vascular diseases. Until now, adequate clinical implementation has required the use of 3 T scanners, which limits wider availability. This study aims to evaluate the interchangeability of a 3D turbo spin echo sequence with variable flip angle MRI sequence (T1 3D Sampling Perfection with Application optimized Contrast using different flip angle Evolution, SPACE) with deep learning image reconstruction for a 1.5 T scanner, with an established sequence (T1 3D SPACE) for a 3 T scanner. In addition, image quality parameters and diagnostic confidence are to be compared.

Materials and methods: Patients were prospectively examined using a T1-weighted turbo spin echo with variable flip angle at 3 T and a similar newly developed sequence with deep learning-based image reconstruction at 1.5 T. The images were read by 3 experienced radiologists regarding the presence of pathologic enhancement of the vessel wall for the interchangeability analysis. Image quality and diagnostic confidence were evaluated using 5-point Likert scales. Interreader and intrareader reliability were calculated for all parameters.

Results: A total of 50 participants (42.6 ± 21.2 y, 26 males) were included. Regarding the presence of pathologic vessel wall enhancement, there was a high interreader agreement [Fleiss kappa = 0.72 (95% CI: 0.62; 0.81) for 1.5T, 0.78 (0.69; 0.88) for 3 T]. The sequences at 1.5 T and 3 T were interchangeable (IEI = 0.008). Image quality at 1.5 T was diagnostic in all cases, but rated superior at 3 T (P < 0.001). Diagnostic confidence was also slightly but significantly higher at 3 T (P < 0.001).

Conclusions: The utilization of deep learning reconstruction enables vessel wall imaging in 1.5 T MRI. This new MRI sequence was interchangeable with established sequences at 3 T for the detection of pathologic vessel wall enhancement. This development could significantly improve the availability of vessel wall imaging in the clinical routine.

使用深度学习重建的1.5 T MRI血管壁成像:与标准3t MRI互换性的前瞻性评估。
目的:血管壁磁共振成像在颅内血管疾病的诊断中具有重要意义。到目前为止,充分的临床实施需要使用3t扫描仪,这限制了更广泛的可用性。本研究旨在评估具有可变翻转角度MRI序列(T1 3D Sampling Perfection with Application optimized Contrast with different flip angle Evolution, SPACE)的3D涡轮自旋回波序列与1.5 T扫描仪的深度学习图像重建序列(T1 3D SPACE)与3t扫描仪的既定序列(T1 3D SPACE)的互换性。此外,图像质量参数和诊断置信度进行比较。材料和方法:患者在3 T时使用t1加权涡轮自旋回波进行前瞻性检查,在1.5 T时使用类似的新开发序列,基于深度学习的图像重建。图像由3名经验丰富的放射科医生阅读,检查血管壁是否存在病理性增强,以进行互换性分析。使用5点李克特量表评估图像质量和诊断置信度。计算了所有参数的读间和读内可靠性。结果:共纳入50例受试者(42.6±21.2岁,男性26例)。关于病理性血管壁增强的存在,有很高的解读一致性[1.5T的Fleiss kappa = 0.72 (95% CI: 0.62; 0.81), 3 T的Fleiss kappa = 0.78(0.69; 0.88)]。1.5 T和3t的序列可互换(IEI = 0.008)。在所有病例中,1.5 T的图像质量都是诊断性的,但在3 T时被评为更好(P < 0.001)。诊断置信度在3 T时也略高但显著(P < 0.001)。结论:利用深度学习重建技术可以实现1.5 T MRI血管壁成像。新的MRI序列可与已建立的3 T序列互换,用于检测病理性血管壁增强。这一进展可以显著提高血管壁成像在临床常规中的可用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书