{"title":"One-Tube RPA-CRISPR-Cas13a assay with rational design for single-molecule detection of waterborne viruses in drinking water treatment.","authors":"Fan Wang, Changhua He, Yingzi Lin, Xiaohong Zhou","doi":"10.1016/j.bios.2026.118983","DOIUrl":null,"url":null,"abstract":"<p><p>The global rise in waterborne viral infections has created an urgent need for portable, highly efficient environmental virus detection technologies. CRISPR-based nucleic acid detection coupled with isothermal amplification (e.g., Recombinase Polymerase Amplification, RPA) shows great promise for field applications. However, most reported designs fail to achieve the single-molecule sensitivity, which significantly limits their practical applications. To bridge the gap, we proposed a rational design strategy for the RPA primer and the CRISPR-Cas13a crRNA, suggesting that sensitivity can be enhanced by simplifying the secondary structure of the crRNA spacer region. Subsequently, we established a portable, one-tube CRISPR-Cas13a bioassay to detect two major waterborne viruses, achieving ultrasensitive detection limits of 5/8 aM for norovirus and 2/3 aM for rotavirus within 40 min. Thereafter, seasonal sampling across different treatment stages of a drinking water treatment plant was conducted, and water samples were analyzed using the one-tube CRISPR-Cas13a bioassay in comparison with qPCR and dPCR, revealing a positive detection rate of 15.79% (6/38) for the one-tube CRISPR-Cas13a bioassay, 18.42% (7/38) for qPCR, and 15.79% (6/38) for dPCR. The assay's modular design allows for broad applicability to other pathogens by simply modifying the target nucleic acid sequence, offering high sensitivity and specificity. This innovation paves the way for deployable point-of-care testing and large-scale spatiotemporal virus monitoring.</p>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"311 ","pages":"118983"},"PeriodicalIF":11.8000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1016/j.bios.2026.118983","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
The global rise in waterborne viral infections has created an urgent need for portable, highly efficient environmental virus detection technologies. CRISPR-based nucleic acid detection coupled with isothermal amplification (e.g., Recombinase Polymerase Amplification, RPA) shows great promise for field applications. However, most reported designs fail to achieve the single-molecule sensitivity, which significantly limits their practical applications. To bridge the gap, we proposed a rational design strategy for the RPA primer and the CRISPR-Cas13a crRNA, suggesting that sensitivity can be enhanced by simplifying the secondary structure of the crRNA spacer region. Subsequently, we established a portable, one-tube CRISPR-Cas13a bioassay to detect two major waterborne viruses, achieving ultrasensitive detection limits of 5/8 aM for norovirus and 2/3 aM for rotavirus within 40 min. Thereafter, seasonal sampling across different treatment stages of a drinking water treatment plant was conducted, and water samples were analyzed using the one-tube CRISPR-Cas13a bioassay in comparison with qPCR and dPCR, revealing a positive detection rate of 15.79% (6/38) for the one-tube CRISPR-Cas13a bioassay, 18.42% (7/38) for qPCR, and 15.79% (6/38) for dPCR. The assay's modular design allows for broad applicability to other pathogens by simply modifying the target nucleic acid sequence, offering high sensitivity and specificity. This innovation paves the way for deployable point-of-care testing and large-scale spatiotemporal virus monitoring.
期刊介绍:
Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.