{"title":"A Novel Hybrid Optimization-Based Controller for AGC in Deregulated Environments With Electric Vehicle Loads","authors":"Ajay Kumar,&nbsp;S Ramana Kumar Joga,&nbsp;Theophilus A. T. Kambo Jr,&nbsp;Chidurala Saiprakash","doi":"10.1002/eng2.70889","DOIUrl":null,"url":null,"abstract":"<p>This paper proposes an IGSA-BPSO optimized hybrid PIDNPDN controller for Automatic Generation Control in a deregulated multisource power system with Electric Vehicle load participation. The hybrid power system considered comprises thermal, hydro, wind, diesel units, and aggregated EV fleets, with physical nonlinearities such as Generation Rate Constraint, Governor Dead Band, and Boiler Dynamics. To overcome the limitations of classical controllers in frequency regulation, an improved hybrid optimization technique—Improved Gravitational Search Algorithm–Binary Particle Swarm Optimization (IGSA-BPSO)—is employed to tune controller gains by minimizing the Integral of Time multiplied Absolute Error. The system is evaluated under Poolco, Bilateral, and Contract Violation Transactions, where the proposed controller consistently demonstrates faster dynamic response, minimal overshoot, and improved robustness against disturbances. The results highlight that the proposed IGSA-BPSO tuned PIDNPDN controller achieves significantly reduced settling times (ΔF<sub>1</sub>: 2.0048 s, ΔF<sub>2</sub>: 1.2261 s, ΔP<sub>tie</sub>: 1.6051 s in Poolco transactions) compared to PID, PIDN, and TIDF controllers. Furthermore, the inclusion of Redox Flow Battery (RFB) and Unified Power Flow Controller in coordination with EV loads yields superior damping of oscillations and frequency stability and demonstrates that integrating EV fleets enhances system flexibility by compensating uncontracted demand during contract violations, thereby improving reliability and environmental sustainability. Overall, the study confirms that the integration of EV loads with IGSA-BPSO optimized hybrid controllers offers a promising pathway for achieving resilient and sustainable AGC in deregulated power systems.</p>","PeriodicalId":72922,"journal":{"name":"Engineering reports : open access","volume":"8 7","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/eng2.70889","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering reports : open access","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eng2.70889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposes an IGSA-BPSO optimized hybrid PIDNPDN controller for Automatic Generation Control in a deregulated multisource power system with Electric Vehicle load participation. The hybrid power system considered comprises thermal, hydro, wind, diesel units, and aggregated EV fleets, with physical nonlinearities such as Generation Rate Constraint, Governor Dead Band, and Boiler Dynamics. To overcome the limitations of classical controllers in frequency regulation, an improved hybrid optimization technique—Improved Gravitational Search Algorithm–Binary Particle Swarm Optimization (IGSA-BPSO)—is employed to tune controller gains by minimizing the Integral of Time multiplied Absolute Error. The system is evaluated under Poolco, Bilateral, and Contract Violation Transactions, where the proposed controller consistently demonstrates faster dynamic response, minimal overshoot, and improved robustness against disturbances. The results highlight that the proposed IGSA-BPSO tuned PIDNPDN controller achieves significantly reduced settling times (ΔF1: 2.0048 s, ΔF2: 1.2261 s, ΔPtie: 1.6051 s in Poolco transactions) compared to PID, PIDN, and TIDF controllers. Furthermore, the inclusion of Redox Flow Battery (RFB) and Unified Power Flow Controller in coordination with EV loads yields superior damping of oscillations and frequency stability and demonstrates that integrating EV fleets enhances system flexibility by compensating uncontracted demand during contract violations, thereby improving reliability and environmental sustainability. Overall, the study confirms that the integration of EV loads with IGSA-BPSO optimized hybrid controllers offers a promising pathway for achieving resilient and sustainable AGC in deregulated power systems.

Abstract Image

一种基于混合优化的非管制环境下电动汽车负载AGC控制器
本文提出了一种IGSA-BPSO优化的混合PIDNPDN控制器,用于电动汽车负荷参与的无管制多源电力系统的自动发电控制。考虑的混合动力系统包括热能、水力、风能、柴油机组和聚合的电动汽车车队,具有发电速率约束、调速器死区和锅炉动力学等物理非线性。为了克服经典控制器在频率调节方面的局限性,采用一种改进的混合优化技术-改进引力搜索算法-二进制粒子群优化(IGSA-BPSO),通过最小化时间乘绝对误差的积分来调节控制器增益。系统在Poolco、双边交易和合同违约交易下进行评估,其中所提出的控制器始终表现出更快的动态响应、最小的超调和更好的抗干扰鲁棒性。结果表明,与PID、PIDN和TIDF控制器相比,所提出的IGSA-BPSO调优的PIDNPDN控制器实现了显著减少的处理时间(在Poolco事务中ΔF1: 2.0048 s, ΔF2: 1.2261 s, ΔPtie: 1.6051 s)。此外,将氧化还原液流电池(RFB)和统一潮流控制器与电动汽车负载相协调,可以产生更好的振荡阻尼和频率稳定性,并表明整合电动汽车车队可以在违反合同时补偿未签约需求,从而提高系统灵活性,从而提高可靠性和环境可持续性。总体而言,该研究证实,将电动汽车负载与IGSA-BPSO优化的混合控制器集成,为在放松管制的电力系统中实现弹性和可持续的AGC提供了一条有希望的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
0.00%
发文量
0
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书