Shenghao Luo, Zhengguo Zhang, Ziye Ling, Xiaoming Fang, Shuping Wang
{"title":"Impact of Water Spray Conditions on Cooling of Thermal-Runaway Lithium-Ion Battery: Mechanisms and Optimization","authors":"Shenghao Luo, Zhengguo Zhang, Ziye Ling, Xiaoming Fang, Shuping Wang","doi":"10.1007/s10694-026-01958-4","DOIUrl":null,"url":null,"abstract":"<div><p>Lithium-ion battery (LIB) incidents remain challenging to mitigate because thermal runaway (TR) cells retain substantial internal heat, which can drive re-ignition and thermal runaway propagation (TRP) if suppression cooling is delayed or under-designed. This study combines pure-water spray cooling experiments on a 51 Ah prismatic NCM cell undergoing TR with a validated three-dimensional heat-transfer model to quantify how spray duration (<span>\\(\\:\\tau\\:\\)</span>), total sprayed mass (<span>\\(\\:{M}_{spray}\\)</span>), nozzle height (<span>\\(\\:{H}_{spray}\\)</span>), and cell properties govern cooling outcomes. Cooling performance is evaluated using the rebound-peak temperature after spray termination (<span>\\(\\:{T}_{reb}\\)</span>) and the cumulative exposure time above 150 °C (<span>\\(\\:{t}_{>150\\:^\\circ\\:C}\\)</span>), where 150 °C is adopted as a conservative threshold for propagation risk. A validated three-dimensional transient heat-transfer model was established to describe post-TR spray cooling, internal heat redistribution, and temperature rebound. Under <span>\\(\\:{M}_{spray}\\)</span> = 5 kg and <span>\\(\\:{H}_{spray}\\)</span> = 0.25 m, τ ≈ 310 s minimizes <span>\\(\\:{t}_{>150\\:^\\circ\\:C}\\)</span> while keeping <span>\\(\\:{T}_{reb}\\)</span> low. The existence of an optimal <span>\\(\\:\\tau\\:\\)</span> reflects a trade-off: short <span>\\(\\:\\tau\\:\\)</span> is limited by internal heat conduction and induces strong post-spray rebound, whereas long <span>\\(\\:\\tau\\:\\)</span> reduces the impingement mass flux and slows the early-stage cooling rate. Increasing <span>\\(\\:{M}_{spray}\\)</span> reduces <span>\\(\\:{t}_{>150\\:^\\circ\\:C}\\)</span> with diminishing returns, and increasing <span>\\(\\:{H}_{spray}\\)</span> monotonically degrades performance. Across prismatic cells, the recommended <span>\\(\\:\\tau\\:\\)</span>shifts with cell geometry and thermal load, consistent with the role of thermal diffusion in post-spray heat redistribution. Finally, a Gaussian process regression surrogate model was developed to predict <span>\\(\\:{T}_{\\text{r}\\text{e}\\text{b}}\\)</span>, <span>\\(\\:{t}_{>150,\\text{D}\\text{S}}\\)</span>, <span>\\(\\:{t}_{>150,\\text{A}\\text{S}}\\)</span>, and <span>\\(\\:{t}_{>150,\\text{t}\\text{o}\\text{t}\\text{a}\\text{l}}\\)</span> from spray conditions and cell-related parameters. Grouped five-fold cross-validation yielded <span>\\(\\:{R}^{2}=0.989-0.997\\)</span>, supporting rapid screening of spray settings within the investigated parameter ranges.</p></div>","PeriodicalId":558,"journal":{"name":"Fire Technology","volume":"62 5","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Technology","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10694-026-01958-4","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Lithium-ion battery (LIB) incidents remain challenging to mitigate because thermal runaway (TR) cells retain substantial internal heat, which can drive re-ignition and thermal runaway propagation (TRP) if suppression cooling is delayed or under-designed. This study combines pure-water spray cooling experiments on a 51 Ah prismatic NCM cell undergoing TR with a validated three-dimensional heat-transfer model to quantify how spray duration (\(\:\tau\:\)), total sprayed mass (\(\:{M}_{spray}\)), nozzle height (\(\:{H}_{spray}\)), and cell properties govern cooling outcomes. Cooling performance is evaluated using the rebound-peak temperature after spray termination (\(\:{T}_{reb}\)) and the cumulative exposure time above 150 °C (\(\:{t}_{>150\:^\circ\:C}\)), where 150 °C is adopted as a conservative threshold for propagation risk. A validated three-dimensional transient heat-transfer model was established to describe post-TR spray cooling, internal heat redistribution, and temperature rebound. Under \(\:{M}_{spray}\) = 5 kg and \(\:{H}_{spray}\) = 0.25 m, τ ≈ 310 s minimizes \(\:{t}_{>150\:^\circ\:C}\) while keeping \(\:{T}_{reb}\) low. The existence of an optimal \(\:\tau\:\) reflects a trade-off: short \(\:\tau\:\) is limited by internal heat conduction and induces strong post-spray rebound, whereas long \(\:\tau\:\) reduces the impingement mass flux and slows the early-stage cooling rate. Increasing \(\:{M}_{spray}\) reduces \(\:{t}_{>150\:^\circ\:C}\) with diminishing returns, and increasing \(\:{H}_{spray}\) monotonically degrades performance. Across prismatic cells, the recommended \(\:\tau\:\)shifts with cell geometry and thermal load, consistent with the role of thermal diffusion in post-spray heat redistribution. Finally, a Gaussian process regression surrogate model was developed to predict \(\:{T}_{\text{r}\text{e}\text{b}}\), \(\:{t}_{>150,\text{D}\text{S}}\), \(\:{t}_{>150,\text{A}\text{S}}\), and \(\:{t}_{>150,\text{t}\text{o}\text{t}\text{a}\text{l}}\) from spray conditions and cell-related parameters. Grouped five-fold cross-validation yielded \(\:{R}^{2}=0.989-0.997\), supporting rapid screening of spray settings within the investigated parameter ranges.
期刊介绍:
Fire Technology publishes original contributions, both theoretical and empirical, that contribute to the solution of problems in fire safety science and engineering. It is the leading journal in the field, publishing applied research dealing with the full range of actual and potential fire hazards facing humans and the environment. It covers the entire domain of fire safety science and engineering problems relevant in industrial, operational, cultural, and environmental applications, including modeling, testing, detection, suppression, human behavior, wildfires, structures, and risk analysis.
The aim of Fire Technology is to push forward the frontiers of knowledge and technology by encouraging interdisciplinary communication of significant technical developments in fire protection and subjects of scientific interest to the fire protection community at large.
It is published in conjunction with the National Fire Protection Association (NFPA) and the Society of Fire Protection Engineers (SFPE). The mission of NFPA is to help save lives and reduce loss with information, knowledge, and passion. The mission of SFPE is advancing the science and practice of fire protection engineering internationally.