Deep learning analysis of single-lead electrocardiograms enables pragmatic heart failure risk assessment in the general population.

IF 4.4 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
European heart journal. Digital health Pub Date : 2026-06-23 eCollection Date: 2026-07-01 DOI:10.1093/ehjdh/ztag099
Meraj Neyazi, Jan P Bremer, Jan Brederecke, Marius S Knorr, Ferdinand Seum, Carla Reinbold, Stefan Gross, Dora Csengeri, Stefan Blankenberg, Marcus Dörr, Marcus Vollmer, Renate Bonin-Schnabel
{"title":"Deep learning analysis of single-lead electrocardiograms enables pragmatic heart failure risk assessment in the general population.","authors":"Meraj Neyazi, Jan P Bremer, Jan Brederecke, Marius S Knorr, Ferdinand Seum, Carla Reinbold, Stefan Gross, Dora Csengeri, Stefan Blankenberg, Marcus Dörr, Marcus Vollmer, Renate Bonin-Schnabel","doi":"10.1093/ehjdh/ztag099","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Effective heart failure (HF) prevention requires early identification of high-risk individuals, yet population-wide stratification remains difficult. We evaluated whether deep learning using single-lead (lead I) electrocardiograms (ECGs), obtainable from medical systems and wearables, enables population-scale risk assessment. We developed AI-HF to estimate incident clinical HF risk using UK Biobank (UKB) data, validating in the prospective SHIP-START and SHIP-TREND cohorts.</p><p><strong>Methods and results: </strong>The analysis included 31 740 UKB participants (median age 64, 5.2 year follow-up, 243 events), 3025 SHIP-START participants (age 50, 15 year follow-up, 166 events), and 1342 SHIP-TREND participants (age 51, 9 year follow-up, 84 events). Participants with prevalent HF were excluded. Performance was evaluated at a harmonized 5-year prediction horizon. C-indices for incident clinical HF were 0.693 [95% confidence interval (CI) 0.654-0.732] in UKB, 0.715 (0.652-0.777) in SHIP-START, and 0.791 (0.749-0.833) in SHIP-TREND. Hazard ratios per standard deviation increase in AI-HF output were 1.67 (1.56-1.79), 1.43 (1.25-1.65), and 1.46 (1.34-1.59), respectively (all <i>P</i> < 0.001). Adding biometric variables improved discrimination modestly (C-indices: 0.714, 0.718, and 0.77).</p><p><strong>Conclusion: </strong>Across cohorts, AI-HF identified individuals at elevated 5-year incident clinical HF risk using single-lead ECGs. Given the ubiquity of wearables, this method may enable population-scale assessment to support targeted prevention and early intervention.</p>","PeriodicalId":72965,"journal":{"name":"European heart journal. Digital health","volume":"7 6","pages":"ztag099"},"PeriodicalIF":4.4000,"publicationDate":"2026-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13326632/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal. Digital health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjdh/ztag099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Effective heart failure (HF) prevention requires early identification of high-risk individuals, yet population-wide stratification remains difficult. We evaluated whether deep learning using single-lead (lead I) electrocardiograms (ECGs), obtainable from medical systems and wearables, enables population-scale risk assessment. We developed AI-HF to estimate incident clinical HF risk using UK Biobank (UKB) data, validating in the prospective SHIP-START and SHIP-TREND cohorts.

Methods and results: The analysis included 31 740 UKB participants (median age 64, 5.2 year follow-up, 243 events), 3025 SHIP-START participants (age 50, 15 year follow-up, 166 events), and 1342 SHIP-TREND participants (age 51, 9 year follow-up, 84 events). Participants with prevalent HF were excluded. Performance was evaluated at a harmonized 5-year prediction horizon. C-indices for incident clinical HF were 0.693 [95% confidence interval (CI) 0.654-0.732] in UKB, 0.715 (0.652-0.777) in SHIP-START, and 0.791 (0.749-0.833) in SHIP-TREND. Hazard ratios per standard deviation increase in AI-HF output were 1.67 (1.56-1.79), 1.43 (1.25-1.65), and 1.46 (1.34-1.59), respectively (all P < 0.001). Adding biometric variables improved discrimination modestly (C-indices: 0.714, 0.718, and 0.77).

Conclusion: Across cohorts, AI-HF identified individuals at elevated 5-year incident clinical HF risk using single-lead ECGs. Given the ubiquity of wearables, this method may enable population-scale assessment to support targeted prevention and early intervention.

单导联心电图的深度学习分析使普通人群的心力衰竭风险评估更加实用。
目的:有效的心力衰竭(HF)预防需要早期识别高危人群,但在人群范围内分层仍然很困难。我们评估了使用从医疗系统和可穿戴设备获得的单导联(lead I)心电图(ecg)进行深度学习是否能够进行人群规模的风险评估。我们开发了AI-HF,利用UK Biobank (UKB)数据来估计临床HF事件风险,并在前瞻性SHIP-START和SHIP-TREND队列中进行验证。方法和结果:分析包括31740名UKB参与者(中位年龄64岁,随访5.2年,243次事件),3025名SHIP-START参与者(50岁,随访15年,166次事件)和1342名SHIP-TREND参与者(51岁,随访9年,84次事件)。排除HF患者。在协调的5年预测范围内评估绩效。UKB组临床HF事件的c -指数为0.693[95%可信区间(CI) 0.654-0.732], SHIP-START组为0.715 (0.652-0.777),SHIP-TREND组为0.791(0.749-0.833)。AI-HF输出每标准差增加的风险比分别为1.67(1.56-1.79)、1.43(1.25-1.65)和1.46(1.34-1.59)(均P < 0.001)。加入生物特征变量略微改善了歧视(c指数:0.714、0.718和0.77)。结论:在所有队列中,AI-HF通过单导联心电图识别出5年临床HF事件风险升高的个体。鉴于可穿戴设备的普遍存在,这种方法可以实现人口规模的评估,以支持有针对性的预防和早期干预。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书