Comparative Visual Outcomes of Toric and Nontoric Intraocular Lenses Featuring Combined Diffractive Extended Depth of Focus and Multifocal Designs.

IF 2.2 4区 医学 Q3 OPHTHALMOLOGY
Journal of Ophthalmology Pub Date : 2026-07-02 eCollection Date: 2026-01-01 DOI:10.1155/joph/3788361
Laureano A Rementería-Capelo, Inés Contreras, Laura Mariñas-García, Vanesa Blázquez, Javier Ruiz-Alcocer
{"title":"Comparative Visual Outcomes of Toric and Nontoric Intraocular Lenses Featuring Combined Diffractive Extended Depth of Focus and Multifocal Designs.","authors":"Laureano A Rementería-Capelo, Inés Contreras, Laura Mariñas-García, Vanesa Blázquez, Javier Ruiz-Alcocer","doi":"10.1155/joph/3788361","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess and compare visual quality and subjective outcomes of the toric and nontoric versions of a trifocal intraocular lens (IOL) combining a diffractive extended depth of focus (EDoF) profile with a diffractive multifocal pattern.</p><p><strong>Methods: </strong>This prospective cohort study included patients bilaterally implanted with the TECNIS Synergy or TECNIS Synergy Toric II IOL. At 3 months postoperatively, monocular and binocular uncorrected distance visual acuity (UDVA), corrected visual acuity (VA) at 100%, 50%, and 10% contrast, and binocular defocus curves were evaluated. A five-point Likert scale questionnaire assessed satisfaction at different distances, perception of halos, and willingness to choose the same lens again.</p><p><strong>Results: </strong>A total of 114 eyes (52 nontoric and 62 toric) were analyzed. Monocular UDVA was 0.02 ± 0.07 logMAR (nontoric) and 0.08 ± 0.11 logMAR (toric) (<i>p</i> = 0.02), while binocular UDVA was -0.05 ± 0.06 logMAR and -0.02 ± 0.10 logMAR, respectively (<i>p</i> = 0.13). Defocus curves showed VA better than 0.1 logMAR from +1.0 to -2.5 D in both groups. No significant differences in contrast sensitivity were observed between groups at any level (<i>p</i> > 0.05). Over 80% of patients in each group reported being satisfied or very satisfied at all distances. Halos were described as not or only slightly bothersome by 42% of patients. A small percentage expressed a low likelihood of choosing the same lens again (4% nontoric, 9% toric).</p><p><strong>Conclusion: </strong>Both IOL models provided similar and effective visual restoration from distance to near. Despite some reported visual disturbances, patient satisfaction and visual quality were high and comparable between the toric and nontoric lenses when appropriately aligned.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":"2026 ","pages":"3788361"},"PeriodicalIF":2.2000,"publicationDate":"2026-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13325403/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/joph/3788361","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess and compare visual quality and subjective outcomes of the toric and nontoric versions of a trifocal intraocular lens (IOL) combining a diffractive extended depth of focus (EDoF) profile with a diffractive multifocal pattern.

Methods: This prospective cohort study included patients bilaterally implanted with the TECNIS Synergy or TECNIS Synergy Toric II IOL. At 3 months postoperatively, monocular and binocular uncorrected distance visual acuity (UDVA), corrected visual acuity (VA) at 100%, 50%, and 10% contrast, and binocular defocus curves were evaluated. A five-point Likert scale questionnaire assessed satisfaction at different distances, perception of halos, and willingness to choose the same lens again.

Results: A total of 114 eyes (52 nontoric and 62 toric) were analyzed. Monocular UDVA was 0.02 ± 0.07 logMAR (nontoric) and 0.08 ± 0.11 logMAR (toric) (p = 0.02), while binocular UDVA was -0.05 ± 0.06 logMAR and -0.02 ± 0.10 logMAR, respectively (p = 0.13). Defocus curves showed VA better than 0.1 logMAR from +1.0 to -2.5 D in both groups. No significant differences in contrast sensitivity were observed between groups at any level (p > 0.05). Over 80% of patients in each group reported being satisfied or very satisfied at all distances. Halos were described as not or only slightly bothersome by 42% of patients. A small percentage expressed a low likelihood of choosing the same lens again (4% nontoric, 9% toric).

Conclusion: Both IOL models provided similar and effective visual restoration from distance to near. Despite some reported visual disturbances, patient satisfaction and visual quality were high and comparable between the toric and nontoric lenses when appropriately aligned.

环形和非环形人工晶状体结合衍射扩展焦深和多焦设计的视觉效果比较。
目的:评估和比较环形和非环形三焦人工晶状体(IOL)结合衍射扩展焦深(EDoF)和衍射多焦模式的视觉质量和主观结果。方法:本前瞻性队列研究纳入双侧植入TECNIS Synergy或TECNIS Synergy Toric II人工晶状体的患者。术后3个月评估单眼和双眼未矫正距离视力(UDVA)、100%、50%和10%对比下的矫正视力(VA)和双眼离焦曲线。李克特五分制调查问卷评估了在不同距离下的满意度、对光晕的感知以及再次选择相同镜片的意愿。结果:共分析114只眼(非环眼52只,环眼62只)。单眼UDVA分别为0.02±0.07 logMAR(非环)和0.08±0.11 logMAR(环)(p = 0.02),双眼UDVA分别为-0.05±0.06 logMAR和-0.02±0.10 logMAR (p = 0.13)。离焦曲线显示,两组在+1.0 ~ -2.5 D范围内VA均优于0.1 logMAR。各组对比敏感度在任何水平上均无显著差异(p < 0.05)。每组中超过80%的患者报告对所有距离都满意或非常满意。42%的患者认为光晕没有或只有轻微的困扰。一小部分人表示再次选择相同镜片的可能性很低(4%非环面,9%环面)。结论:两种人工晶状体模型具有相似的近距视力恢复效果。尽管有一些视力障碍的报道,患者的满意度和视觉质量是高的,并且在适当对齐的环形和非环形晶状体之间是相当的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书