Stable Tracking-in-the-Loop Control of Cable-Driven RCM Surgical Manipulators Under Erroneous Kinematic Chains

IF 5.3 2区 计算机科学 Q2 ROBOTICS
IEEE Robotics and Automation Letters Pub Date : 2026-07-01 Epub Date: 2026-06-01 DOI:10.1109/LRA.2026.3699136
Neelay Joglekar;Fei Liu;Florian Richter;Michael C. Yip
{"title":"Stable Tracking-in-the-Loop Control of Cable-Driven RCM Surgical Manipulators Under Erroneous Kinematic Chains","authors":"Neelay Joglekar;Fei Liu;Florian Richter;Michael C. Yip","doi":"10.1109/LRA.2026.3699136","DOIUrl":null,"url":null,"abstract":"Remote Center of Motion (RCM) robotic manipulators have revolutionized Minimally Invasive Surgery, enabling precise, dexterous surgical manipulation within the patient's body cavity without disturbing the insertion point on the patient. Accurate RCM tool control is vital for incorporating autonomous subtasks like suturing, blood suction, and tumor resection into robotic surgical procedures, reducing surgeon fatigue and improving patient outcomes. However, these cable-driven systems are subject to significant joint reading errors, corrupting the kinematics computation necessary to perform control. Although visual tracking with endoscopic cameras can correct errors on in-view joints, errors in the kinematic chain prior to the insertion point are irreparable because they remain out of view. No prior work has characterized the stability of control under these conditions. We fill this gap by designing a provably stable tracking-in-the-loop controller for the out-of-view portion of the RCM manipulator kinematic chain. We additionally incorporate this controller into a bilevel control scheme for the full kinematic chain. We rigorously benchmark our method in simulated and real world settings to verify our theoretical findings. Our work provides key insights into the next steps required for the transition from teleoperated to autonomous surgery.","PeriodicalId":13241,"journal":{"name":"IEEE Robotics and Automation Letters","volume":"11 7","pages":"8608-8615"},"PeriodicalIF":5.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Robotics and Automation Letters","FirstCategoryId":"94","ListUrlMain":"https://ieeexplore.ieee.org/document/11543209/","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ROBOTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Remote Center of Motion (RCM) robotic manipulators have revolutionized Minimally Invasive Surgery, enabling precise, dexterous surgical manipulation within the patient's body cavity without disturbing the insertion point on the patient. Accurate RCM tool control is vital for incorporating autonomous subtasks like suturing, blood suction, and tumor resection into robotic surgical procedures, reducing surgeon fatigue and improving patient outcomes. However, these cable-driven systems are subject to significant joint reading errors, corrupting the kinematics computation necessary to perform control. Although visual tracking with endoscopic cameras can correct errors on in-view joints, errors in the kinematic chain prior to the insertion point are irreparable because they remain out of view. No prior work has characterized the stability of control under these conditions. We fill this gap by designing a provably stable tracking-in-the-loop controller for the out-of-view portion of the RCM manipulator kinematic chain. We additionally incorporate this controller into a bilevel control scheme for the full kinematic chain. We rigorously benchmark our method in simulated and real world settings to verify our theoretical findings. Our work provides key insights into the next steps required for the transition from teleoperated to autonomous surgery.
错误运动链下缆索驱动RCM手术机械臂的稳定环内跟踪控制。
远程运动中心(RCM)机器人操纵器已经彻底改变了微创手术,实现了在患者体腔内精确,灵巧的手术操作,而不会干扰患者的插入点。精确的RCM工具控制对于将缝合、吸血和肿瘤切除等自主子任务纳入机器人手术过程、减少外科医生疲劳和改善患者预后至关重要。然而,这些缆索驱动的系统存在明显的关节读取误差,破坏了执行控制所需的运动学计算。虽然内窥镜相机的视觉跟踪可以纠正在可视关节上的错误,但在插入点之前的运动链上的错误是不可修复的,因为它们仍然在视野之外。在这些条件下,没有任何先前的工作描述过控制的稳定性。我们通过设计一个可证明稳定的RCM机械手运动链外部分的环内跟踪控制器来填补这一空白。此外,我们还将该控制器合并到全运动链的双层控制方案中。我们严格地在模拟和现实世界设置中对我们的方法进行基准测试,以验证我们的理论发现。我们的工作为从远程手术过渡到自主手术所需的下一步提供了关键见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Robotics and Automation Letters
IEEE Robotics and Automation Letters Computer Science-Computer Science Applications
CiteScore
9.60
自引率
15.40%
发文量
1428
期刊介绍: The scope of this journal is to publish peer-reviewed articles that provide a timely and concise account of innovative research ideas and application results, reporting significant theoretical findings and application case studies in areas of robotics and automation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书