The Association of Serum Chemerin Levels with Coronary Plaque Burden Assessed by Intravascular Ultrasound in Patients with Chronic Coronary Syndrome.

IF 1.1 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Journal of Cardiovascular Echography Pub Date : 2026-05-06 eCollection Date: 2026-03-01 DOI:10.4103/jcecho.jcecho_133_25
Mohamed Fahmy Elnoamany, Nouran Ahmed Raafat Mohamed Gaballa, Fatma Elzahraa Abdelmoniem Zein
{"title":"The Association of Serum Chemerin Levels with Coronary Plaque Burden Assessed by Intravascular Ultrasound in Patients with Chronic Coronary Syndrome.","authors":"Mohamed Fahmy Elnoamany, Nouran Ahmed Raafat Mohamed Gaballa, Fatma Elzahraa Abdelmoniem Zein","doi":"10.4103/jcecho.jcecho_133_25","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Chemerin has emerged as a proinflammatory adipokine implicated in atherosclerotic processes. Yet, its connection with coronary plaque burden in the setting of chronic coronary syndrome (CCS) has not been comprehensively studied. This study aims to examine the association between serum chemerin concentrations and intravascular ultrasound (IVUS)-based assessment of coronary plaque burden in CCS cases.</p><p><strong>Patients and methods: </strong>This prospective case-control investigation included 80 cases undergoing elective coronary angiography - 50 with <i>de novo</i> atherosclerotic lesions (cases) and 30 with angiographically normal coronaries (controls). Serum chemerin was measured by enzyme-linked immunosorbent assay. Assessment of plaque burden was performed with IVUS, whereas angiographic severity was evaluated by applying the Gensini, SYNTAX, and severity scoring systems.</p><p><strong>Results: </strong>Cases exhibited substantially elevated serum chemerin levels relative to controls (median: 346.6 vs. 93 ng/mL; <i>P</i> < 0.001). The mean plaque burden assessed by IVUS was 72 ± 16%. Chemerin concentrations were positively correlated with the severity score (<i>r</i> = 0.63, <i>P</i> < 0.001), Gensini score (<i>r</i> = 0.48, <i>P</i> = 0.001), and IVUS-derived plaque burden (<i>r</i> = 0.71, <i>P</i> < 0.001). Receiver-operating characteristic analysis demonstrated excellent diagnostic accuracy for chemerin in identifying CCS (area under the curve = 0.948; sensitivity 90%, specificity 100% at a cutoff >155 ng/mL). In multivariate analysis, chemerin was the strongest independent predictor of CCS (odds ratio = 1.047; 95% confidence interval: 1.019-1.075; <i>P</i> = 0.001) and plaque burden (β = 0.096; <i>P</i> < 0.001).</p><p><strong>Conclusions: </strong>Serum chemerin is a valuable noninvasive biomarker for identifying cases with high-risk atherosclerotic disease; however, no long-term follow-up data were available in this study.</p>","PeriodicalId":15191,"journal":{"name":"Journal of Cardiovascular Echography","volume":"36 2","pages":"156-163"},"PeriodicalIF":1.1000,"publicationDate":"2026-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13322585/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Echography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcecho.jcecho_133_25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Chemerin has emerged as a proinflammatory adipokine implicated in atherosclerotic processes. Yet, its connection with coronary plaque burden in the setting of chronic coronary syndrome (CCS) has not been comprehensively studied. This study aims to examine the association between serum chemerin concentrations and intravascular ultrasound (IVUS)-based assessment of coronary plaque burden in CCS cases.

Patients and methods: This prospective case-control investigation included 80 cases undergoing elective coronary angiography - 50 with de novo atherosclerotic lesions (cases) and 30 with angiographically normal coronaries (controls). Serum chemerin was measured by enzyme-linked immunosorbent assay. Assessment of plaque burden was performed with IVUS, whereas angiographic severity was evaluated by applying the Gensini, SYNTAX, and severity scoring systems.

Results: Cases exhibited substantially elevated serum chemerin levels relative to controls (median: 346.6 vs. 93 ng/mL; P < 0.001). The mean plaque burden assessed by IVUS was 72 ± 16%. Chemerin concentrations were positively correlated with the severity score (r = 0.63, P < 0.001), Gensini score (r = 0.48, P = 0.001), and IVUS-derived plaque burden (r = 0.71, P < 0.001). Receiver-operating characteristic analysis demonstrated excellent diagnostic accuracy for chemerin in identifying CCS (area under the curve = 0.948; sensitivity 90%, specificity 100% at a cutoff >155 ng/mL). In multivariate analysis, chemerin was the strongest independent predictor of CCS (odds ratio = 1.047; 95% confidence interval: 1.019-1.075; P = 0.001) and plaque burden (β = 0.096; P < 0.001).

Conclusions: Serum chemerin is a valuable noninvasive biomarker for identifying cases with high-risk atherosclerotic disease; however, no long-term follow-up data were available in this study.

慢性冠脉综合征患者血管内超声评估血清趋化素水平与冠脉斑块负荷的关系
背景:趋化素是一种与动脉粥样硬化过程有关的促炎脂肪因子。然而,其与慢性冠脉综合征(CCS)冠脉斑块负荷的关系尚未得到全面的研究。本研究旨在探讨血清趋化素浓度与基于血管内超声(IVUS)评估CCS病例冠状动脉斑块负荷之间的关系。患者和方法:本前瞻性病例对照研究包括80例接受选择性冠状动脉造影的患者,其中50例为新发动脉粥样硬化病变(病例),30例为冠状动脉造影正常(对照组)。采用酶联免疫吸附法测定血清趋化素。通过IVUS评估斑块负担,而血管造影严重程度则通过Gensini、SYNTAX和严重程度评分系统进行评估。结果:与对照组相比,患者血清趋化素水平显著升高(中位数:346.6 vs 93 ng/mL; P < 0.001)。IVUS评估的平均斑块负荷为72±16%。Chemerin浓度与严重程度评分(r = 0.63, P < 0.001)、Gensini评分(r = 0.48, P = 0.001)和ivus源性斑块负担(r = 0.71, P < 0.001)呈正相关。受体工作特征分析显示,chemerin在鉴别CCS方面具有优异的诊断准确性(曲线下面积= 0.948,灵敏度90%,特异性100%,截止浓度为155 ng/mL)。在多变量分析中,趋化素是CCS(优势比= 1.047;95%可信区间:1.019-1.075;P = 0.001)和斑块负担(β = 0.096; P < 0.001)最强的独立预测因子。结论:血清趋化素是一种有价值的无创生物标志物,可用于鉴别高危动脉粥样硬化疾病;然而,本研究没有长期随访数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiovascular Echography
Journal of Cardiovascular Echography CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
1.40
自引率
12.50%
发文量
27
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书