Retrievable Silicone-Covered Esophageal Stent-Assisted Endoscopic Extraction of a High-Risk Clasp-Retained Denture Impacted at the Aortic Arch Level of the Esophagus: A Case Report.

IF 0.7 Q4 GASTROENTEROLOGY & HEPATOLOGY
Case Reports in Gastroenterology Pub Date : 2026-04-28 eCollection Date: 2026-01-01 DOI:10.1159/000552200
Jing Liu, Yisheng Wei
{"title":"Retrievable Silicone-Covered Esophageal Stent-Assisted Endoscopic Extraction of a High-Risk Clasp-Retained Denture Impacted at the Aortic Arch Level of the Esophagus: A Case Report.","authors":"Jing Liu, Yisheng Wei","doi":"10.1159/000552200","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Clasp-retained dentures are high-risk esophageal foreign bodies that carry a substantial risk of severe esophageal injury. Reliable protection strategies are therefore critical for safe endoscopic extraction. We present a case of successful endoscopic removal of a clasp-retained denture impacted at the aortic arch level using a retrievable silicone-covered esophageal stent as a protection device.</p><p><strong>Case presentation: </strong>A 50-year-old man with hypertension and coronary stent implantation was admitted with retrosternal pain and dysphagia for 4 h after accidental ingestion of a broken denture. Computed tomography confirmed a 1.3 × 2.0 × 4.7 cm foreign body impacted at the aortic arch level. The foreign body was successfully removed under general anesthesia with tracheal intubation, and no intraoperative complications occurred. Postoperative recovery was uneventful. Telephone follow-up at 1 week, 1 month, and 3 months showed that the patient had a normal diet with no discomfort, and the patient declined endoscopic reexamination.</p><p><strong>Conclusion: </strong>This case confirms that a retrievable silicone-covered esophageal stent is a safe and feasible protection device for endoscopic extraction of high-risk dentures at the aortic arch level, with favorable short- and medium-term outcomes. It provides a valuable clinical reference for managing such life-threatening foreign bodies.</p>","PeriodicalId":9614,"journal":{"name":"Case Reports in Gastroenterology","volume":"20 1","pages":"167-174"},"PeriodicalIF":0.7000,"publicationDate":"2026-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13322698/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Gastroenterology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000552200","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Clasp-retained dentures are high-risk esophageal foreign bodies that carry a substantial risk of severe esophageal injury. Reliable protection strategies are therefore critical for safe endoscopic extraction. We present a case of successful endoscopic removal of a clasp-retained denture impacted at the aortic arch level using a retrievable silicone-covered esophageal stent as a protection device.

Case presentation: A 50-year-old man with hypertension and coronary stent implantation was admitted with retrosternal pain and dysphagia for 4 h after accidental ingestion of a broken denture. Computed tomography confirmed a 1.3 × 2.0 × 4.7 cm foreign body impacted at the aortic arch level. The foreign body was successfully removed under general anesthesia with tracheal intubation, and no intraoperative complications occurred. Postoperative recovery was uneventful. Telephone follow-up at 1 week, 1 month, and 3 months showed that the patient had a normal diet with no discomfort, and the patient declined endoscopic reexamination.

Conclusion: This case confirms that a retrievable silicone-covered esophageal stent is a safe and feasible protection device for endoscopic extraction of high-risk dentures at the aortic arch level, with favorable short- and medium-term outcomes. It provides a valuable clinical reference for managing such life-threatening foreign bodies.

食管主动脉弓位阻生高危险卡环保留义齿内镜下可回收硅胶覆盖食管支架拔除1例
卡环固位义齿是一种高风险的食管异物,具有严重的食管损伤风险。因此,可靠的保护策略对于安全的内窥镜摘除至关重要。我们提出了一个案例成功的内窥镜去除在主动脉弓水平阻生卡环保留义齿使用可回收的硅胶覆盖食管支架作为保护装置。病例介绍:一名50岁的高血压患者,冠状动脉支架植入术后,因误食破损的义齿后出现胸骨后疼痛和吞咽困难4小时入院。计算机断层扫描证实一1.3 × 2.0 × 4.7 cm的异物撞击主动脉弓水平。全麻气管插管下异物顺利取出,无术中并发症发生。术后恢复顺利。电话随访1周、1个月、3个月,患者饮食正常,无不适,拒绝内镜复查。结论:本病例证实可回收硅胶覆盖食管支架是一种安全可行的保护装置,用于内镜下主动脉弓处高危义齿拔除,中短期效果良好。为处理此类危及生命的异物提供了有价值的临床参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Case Reports in Gastroenterology
Case Reports in Gastroenterology Medicine-Gastroenterology
CiteScore
1.10
自引率
0.00%
发文量
99
审稿时长
7 weeks
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书