{"title":"Effects of simulated gastric acid ageing on Martens hardness of denture base resins fabricated using different techniques.","authors":"Abdulaziz Alhotan, Ahmed Altarazi, Shaymaa Mudhaffer, Hanan Al-Johani, Nick Silikas","doi":"10.1016/j.dental.2026.06.020","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Gastro-oesophageal reflux disease exposes denture base resins to acidic conditions that may compromise their mechanical properties. This study assessed the effect of simulated gastric acid ageing on the Martens parameters of heat-polymerised, CAD/CAM milled, and 3D-printed polymethyl methacrylate (PMMA).</p><p><strong>Methods: </strong>Three denture base resins were investigated: heat-polymerised (Lucitone 199), CAD/CAM milled (G-CAM), and 3D-printed (Denturetec). Specimens (n = 5 per group) were aged in artificial saliva (pH 5.5) or simulated gastric acid (pH 1.2) at 37°C for 24 and 96 h, corresponding to approximately 2.5 and 10 years of clinical exposure. Martens indentation testing was performed, and the following parameters were measured; Martens hardness (H<sub>M</sub>), indentation depth (I<sub>D</sub>), indentation modulus (E<sub>IT</sub>), and creep indentation (C<sub>IT</sub>). Data were analysed using two-way ANOVA and Tukey post hoc tests (α = 0.05).</p><p><strong>Results: </strong>Resin type significantly affected all Martens parameters (p < 0.001), with milled resin exhibiting the highest H<sub>M</sub> and E<sub>IT</sub> values and 3D-printed resin showing the highest I<sub>D</sub> values. Ageing solvent significantly impacted H<sub>M</sub>, I<sub>D</sub>, and E<sub>IT</sub> (p ≤ 0.049). Gastric acid exposure caused significant deterioration in Martens parameters, particularly at 96 h. Heat-polymerised and milled PMMA exhibited significant differences between solvents at specific time points, whereas 3D-printed resins remained largely unaffected by the ageing solvent.</p><p><strong>Significance: </strong>These findings suggest that material selection based on fabrication technique may influence denture longevity in patients with chronic acid exposure, such as those with gastro-oesophageal reflux disease or eating disorders. The immersion-to-clinical time equivalence represents an approximation based on previously published accelerated ageing models and should be interpreted as a standardised testing protocol rather than an exact clinical simulation.</p>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":" ","pages":""},"PeriodicalIF":6.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.dental.2026.06.020","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Gastro-oesophageal reflux disease exposes denture base resins to acidic conditions that may compromise their mechanical properties. This study assessed the effect of simulated gastric acid ageing on the Martens parameters of heat-polymerised, CAD/CAM milled, and 3D-printed polymethyl methacrylate (PMMA).
Methods: Three denture base resins were investigated: heat-polymerised (Lucitone 199), CAD/CAM milled (G-CAM), and 3D-printed (Denturetec). Specimens (n = 5 per group) were aged in artificial saliva (pH 5.5) or simulated gastric acid (pH 1.2) at 37°C for 24 and 96 h, corresponding to approximately 2.5 and 10 years of clinical exposure. Martens indentation testing was performed, and the following parameters were measured; Martens hardness (HM), indentation depth (ID), indentation modulus (EIT), and creep indentation (CIT). Data were analysed using two-way ANOVA and Tukey post hoc tests (α = 0.05).
Results: Resin type significantly affected all Martens parameters (p < 0.001), with milled resin exhibiting the highest HM and EIT values and 3D-printed resin showing the highest ID values. Ageing solvent significantly impacted HM, ID, and EIT (p ≤ 0.049). Gastric acid exposure caused significant deterioration in Martens parameters, particularly at 96 h. Heat-polymerised and milled PMMA exhibited significant differences between solvents at specific time points, whereas 3D-printed resins remained largely unaffected by the ageing solvent.
Significance: These findings suggest that material selection based on fabrication technique may influence denture longevity in patients with chronic acid exposure, such as those with gastro-oesophageal reflux disease or eating disorders. The immersion-to-clinical time equivalence represents an approximation based on previously published accelerated ageing models and should be interpreted as a standardised testing protocol rather than an exact clinical simulation.
期刊介绍:
Dental Materials publishes original research, review articles, and short communications.
Academy of Dental Materials members click here to register for free access to Dental Materials online.
The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology.
Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.