{"title":"Study on Optimal Optical Parameters for Cutting Liver Tissue with a Novel 980/1470 nm Dual-Wavelength Semiconductor Laser.","authors":"Yiwen Lu, Gaoqi Liu, Kuiyuan Chai, Zien Xu, Mohan Lu, Linxin Shen, Meng Zhao, Le Jiang, Rongqian Wu, Lihui Pang, Yi Lyu, Rongfeng Wang","doi":"10.1177/25785478261465277","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Laser-tissue interactions induce photothermal effects governed by wavelength-dependent absorption and circulation of energy. While 980 nm targets hemoglobin for hemostasis and 1470 nm targets water for vaporization, their synergistic optimization in living liver tissue remains undefined, as existing studies predominantly examine <i>ex vivo</i> models or single wavelengths. This study establishes quantitative relationships between laser parameters and tissue outcomes in an <i>in vivo</i> model.</p><p><strong>Methods: </strong>Twenty rabbits (female New Zealand White, 1.5-2 kg) underwent hepatic transection using a 400 μm bare fiber diameter (3 mm tissue distance, 10 mm/s advancement speed) in continuous-wave (CW) and pulsed-modulated (100 ms pulse, 50% duty cycle, 5 Hz) modes. Output power: 980 nm (12-160 W) and 1470 nm (6-48 W), with different dual-wavelength power ratios. Measured outcomes: cutting depth, vaporization depth, coagulation depth, and thermal injury depth (quantified by hematoxylin and eosin staining).</p><p><strong>Statistics: </strong>analysis of variance for continuous variables, chi-square/Fisher's exact test for categorical variables, and the Mann-Whitney <i>U</i> test for non-normal distributions (<i>p</i> < 0.05).</p><p><strong>Results: </strong>CW mode achieved greater cutting depth than pulsed-modulated mode (median 943.97 μm vs. 689.43 μm, <i>p</i> < 0.05). In CW mode, 1470 nm-dominated ratios (0:1, 1:1, 1:2, 1:3, 1:4) achieved greater cutting depths than 980 nm alone (1:0). Cutting depth increased with peak power from 6 to 120 W, then decreased at 160 W due to carbonization. At 24 W total power with 1:2 ratio (8 W 980 nm/16 W 1470 nm), cutting depth was 1249.3 ± 15.55 μm, vaporization depth 739.5 ± 35.32 μm, coagulation depth 1302 ± 125.44 μm, and thermal damage 1987.53 ± 154.61 μm.</p><p><strong>Conclusions: </strong>The 980/1470 nm wavelength power ratio of 8/16 W in CW mode for liver tissue cutting offers high efficiency, safety, and minimal thermal damage, providing an effective surgical energy device for minimally invasive and precise treatment.</p>","PeriodicalId":94169,"journal":{"name":"Photobiomodulation, photomedicine, and laser surgery","volume":" ","pages":"483-493"},"PeriodicalIF":1.8000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photobiomodulation, photomedicine, and laser surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/25785478261465277","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Laser-tissue interactions induce photothermal effects governed by wavelength-dependent absorption and circulation of energy. While 980 nm targets hemoglobin for hemostasis and 1470 nm targets water for vaporization, their synergistic optimization in living liver tissue remains undefined, as existing studies predominantly examine ex vivo models or single wavelengths. This study establishes quantitative relationships between laser parameters and tissue outcomes in an in vivo model.

Methods: Twenty rabbits (female New Zealand White, 1.5-2 kg) underwent hepatic transection using a 400 μm bare fiber diameter (3 mm tissue distance, 10 mm/s advancement speed) in continuous-wave (CW) and pulsed-modulated (100 ms pulse, 50% duty cycle, 5 Hz) modes. Output power: 980 nm (12-160 W) and 1470 nm (6-48 W), with different dual-wavelength power ratios. Measured outcomes: cutting depth, vaporization depth, coagulation depth, and thermal injury depth (quantified by hematoxylin and eosin staining).

Statistics: analysis of variance for continuous variables, chi-square/Fisher's exact test for categorical variables, and the Mann-Whitney U test for non-normal distributions (p < 0.05).

Results: CW mode achieved greater cutting depth than pulsed-modulated mode (median 943.97 μm vs. 689.43 μm, p < 0.05). In CW mode, 1470 nm-dominated ratios (0:1, 1:1, 1:2, 1:3, 1:4) achieved greater cutting depths than 980 nm alone (1:0). Cutting depth increased with peak power from 6 to 120 W, then decreased at 160 W due to carbonization. At 24 W total power with 1:2 ratio (8 W 980 nm/16 W 1470 nm), cutting depth was 1249.3 ± 15.55 μm, vaporization depth 739.5 ± 35.32 μm, coagulation depth 1302 ± 125.44 μm, and thermal damage 1987.53 ± 154.61 μm.

Conclusions: The 980/1470 nm wavelength power ratio of 8/16 W in CW mode for liver tissue cutting offers high efficiency, safety, and minimal thermal damage, providing an effective surgical energy device for minimally invasive and precise treatment.

新型980/1470 nm双波长半导体激光器切割肝脏组织的最佳光学参数研究。
目的:激光与组织相互作用诱导光热效应,光热效应由波长依赖的能量吸收和循环控制。虽然980 nm的目标是血红蛋白止血,1470 nm的目标是水蒸发,但它们在活体肝组织中的协同优化仍未确定,因为现有的研究主要是研究离体模型或单一波长。本研究在体内模型中建立了激光参数与组织结果之间的定量关系。方法:20只新西兰白兔(雌性,1.5 ~ 2 kg)在连续波(CW)和脉冲调制(100 ms脉冲,50%占空比,5 Hz)模式下,采用400 μm裸纤维直径(3 mm组织距离,10 mm/s推进速度)进行肝脏横断。输出功率:980 nm (12 ~ 160 W)、1470 nm (6 ~ 48 W),双波长功率比不同。测量结果:切割深度、蒸发深度、凝固深度和热损伤深度(苏木精和伊红染色量化)。统计学:对连续变量进行方差分析,对分类变量进行卡方/Fisher精确检验,对非正态分布进行Mann-Whitney U检验(p < 0.05)。结果:连续波模式的切割深度大于脉冲调制模式(中位数943.97 μm vs. 689.43 μm, p < 0.05)。在连续模式下,1470 nm占主导的比例(0:1,1:1,1:2,1:3,1:4)比单独980 nm(1:0)获得更大的切割深度。切割深度随峰值功率从6 W增加到120 W,在峰值功率为160 W时由于碳化作用而减小。在24 W总功率和1:2比例(8 W 980 nm/16 W 1470 nm)下,切割深度为1249.3±15.55 μm,蒸发深度为739.5±35.32 μm,凝固深度为1302±125.44 μm,热损伤为1987.53±154.61 μm。结论:980/1470 nm波长功率比为8/16 W的连续波模式下肝组织切割效率高、安全、热损伤小,为微创、精准治疗提供了一种有效的手术能量装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
期刊介绍: Photobiomodulation, Photomedicine, and Laser Surgery Editor-in-Chief: Michael R Hamblin, PhD Co-Editor-in-Chief: Heidi Abrahamse, PhD
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书