Prognostic Utility of the Dicrotic Notch Index in Patients Undergoing Transcatheter Aortic Valve Replacement

IF 3.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Structural Heart Pub Date : 2026-07-01 Epub Date: 2026-04-11 DOI:10.1016/j.shj.2026.100849
Odette Iskandar MD, Shivabalan Kathavaryan Ramu MD, Maryam Majeed-Saidan MD, Nikolos Spilias MD, Habib Layoun MD, James Yun MD, Grant Reed MD, Rishi Puri MD, Amar Krishnaswamy MD, Samir R. Kapadia MD
{"title":"Prognostic Utility of the Dicrotic Notch Index in Patients Undergoing Transcatheter Aortic Valve Replacement","authors":"Odette Iskandar MD,&nbsp;Shivabalan Kathavaryan Ramu MD,&nbsp;Maryam Majeed-Saidan MD,&nbsp;Nikolos Spilias MD,&nbsp;Habib Layoun MD,&nbsp;James Yun MD,&nbsp;Grant Reed MD,&nbsp;Rishi Puri MD,&nbsp;Amar Krishnaswamy MD,&nbsp;Samir R. Kapadia MD","doi":"10.1016/j.shj.2026.100849","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The dicrotic notch (DN) on the central aortic pressure waveform reflects aortic valve closure. We aimed to assess the clinical utility of the DN index (DNI) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR).</div></div><div><h3>Methods</h3><div>In this retrospective study, we analyzed 569 patients with aortic stenosis who underwent TAVR between January 2019 and December 2020. Aortic waveform data were used to measure systolic, diastolic, and DN pressures, whereas DNI was calculated as (systolic pressure − DN)/pulse pressure. Pre-TAVR and post-TAVR hemodynamic parameters were compared, and survival analysis was performed using Cox regression with post-TAVR/pre-TAVR DNI ratio as an independent covariate.</div></div><div><h3>Results</h3><div>Compared to pre-TAVR, DN pressure (92.18 to 95.37, <em>p</em> &lt; 0.001) and DNI (0.45 to 0.58, <em>p</em> &lt; 0.001) significantly increased post TAVR. Higher baseline DNI was predicted by carotid disease, diabetes mellitus, and a higher ejection fraction at baseline. Post-TAVR to pre-TAVR DNI ratio cut point &gt;1.19 is an independent predictor of event-free survival at 2 years. Patients with higher post-DNI/pre-DNI ratio had a significantly lower risk of all-cause mortality in adjusted analyses (hazard ratio: 0.53, 95% confidence interval [CI]: 0.34–0.82).</div></div><div><h3>Conclusions</h3><div>More than 20% increase in DNI post-TAVR was associated with a lower long-term risk of all-cause mortality. Further studies are needed to understand the determinants of the increase in DNI and if this can be modulated by procedural modifications.</div></div>","PeriodicalId":36053,"journal":{"name":"Structural Heart","volume":"10 7","pages":"Article 100849"},"PeriodicalIF":3.4000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13316582/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Heart","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2474870626000588","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The dicrotic notch (DN) on the central aortic pressure waveform reflects aortic valve closure. We aimed to assess the clinical utility of the DN index (DNI) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR).

Methods

In this retrospective study, we analyzed 569 patients with aortic stenosis who underwent TAVR between January 2019 and December 2020. Aortic waveform data were used to measure systolic, diastolic, and DN pressures, whereas DNI was calculated as (systolic pressure − DN)/pulse pressure. Pre-TAVR and post-TAVR hemodynamic parameters were compared, and survival analysis was performed using Cox regression with post-TAVR/pre-TAVR DNI ratio as an independent covariate.

Results

Compared to pre-TAVR, DN pressure (92.18 to 95.37, p < 0.001) and DNI (0.45 to 0.58, p < 0.001) significantly increased post TAVR. Higher baseline DNI was predicted by carotid disease, diabetes mellitus, and a higher ejection fraction at baseline. Post-TAVR to pre-TAVR DNI ratio cut point >1.19 is an independent predictor of event-free survival at 2 years. Patients with higher post-DNI/pre-DNI ratio had a significantly lower risk of all-cause mortality in adjusted analyses (hazard ratio: 0.53, 95% confidence interval [CI]: 0.34–0.82).

Conclusions

More than 20% increase in DNI post-TAVR was associated with a lower long-term risk of all-cause mortality. Further studies are needed to understand the determinants of the increase in DNI and if this can be modulated by procedural modifications.
Dicrotic Notch指数在经导管主动脉瓣置换术患者中的预后价值。
背景:中央主动脉压力波形上的双向切迹(DN)反映主动脉瓣闭合。我们旨在评估DN指数(DNI)在接受经导管主动脉瓣置换术(TAVR)的严重主动脉瓣狭窄患者中的临床应用。方法:在这项回顾性研究中,我们分析了2019年1月至2020年12月期间接受TAVR治疗的569例主动脉瓣狭窄患者。主动脉波形数据用于测量收缩压、舒张压和DN压,而DNI计算为(收缩压- DN)/脉压。比较tavr前和tavr后的血流动力学参数,采用Cox回归进行生存分析,tavr后/ tavr前DNI比值为独立协变量。结果:与术前相比,术后DN压(92.18 ~ 95.37,p < 0.001)和DNI (0.45 ~ 0.58, p < 0.001)显著升高。较高的基线DNI与颈动脉疾病、糖尿病和较高的基线射血分数有关。tavr后与tavr前的DNI比值切点bbb1.19是2年无事件生存的独立预测因子。在校正分析中,dni后/ dni前比值较高的患者全因死亡风险显著降低(风险比:0.53,95%可信区间[CI]: 0.34-0.82)。结论:tavr后DNI增加20%以上与全因死亡的长期风险降低相关。需要进一步的研究来了解DNI增加的决定因素,以及是否可以通过程序修改来调节。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Structural Heart
Structural Heart Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.60
自引率
0.00%
发文量
81
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书