Comparative Evaluation of Fluorescein Diacetate/Ethidium Bromide Viability Microscopy and Ziehl-Neelsen Staining for Rapid Diagnosis of Pulmonary Tuberculosis.

IF 1.3 Q4 INFECTIOUS DISEASES
International Journal of Mycobacteriology Pub Date : 2026-04-01 Epub Date: 2026-06-30 DOI:10.4103/ijmy.ijmy_243_25
Shubhendu Singh, Dakshina Bisht, Ajoy Kumar Verma, Ashutosh Rawat
{"title":"Comparative Evaluation of Fluorescein Diacetate/Ethidium Bromide Viability Microscopy and Ziehl-Neelsen Staining for Rapid Diagnosis of Pulmonary Tuberculosis.","authors":"Shubhendu Singh, Dakshina Bisht, Ajoy Kumar Verma, Ashutosh Rawat","doi":"10.4103/ijmy.ijmy_243_25","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ziehl-Neelsen (ZN) staining is routinely used for tuberculosis (TB) diagnosis, but cannot differentiate viable from nonviable bacilli. This limitation is particularly relevant in smear-positive pulmonary TB patients, where assessment of treatment response is essential. Fluorescein diacetate/ethidium bromide (FDA/EtBr) viability microscopy detects live Mycobacterium tuberculosis based on metabolic activity. This study compared the diagnostic performance of FDA/EtBr microscopy with ZN staining, using culture and drug susceptibility testing (DST) as the reference standard.</p><p><strong>Methods: </strong>A cross-sectional study was conducted on 300 smear-positive pulmonary TB patients at Santosh Medical College, Ghaziabad, and National Institute of TB and Respiratory Diseases, New Delhi. After n-acetyl-l-cysteine-sodium hydroxide decontamination, sputum samples were examined using ZN staining, FDA/EtBr viability microscopy, and mycobacteria growth indicator tube 960 culture/DST. Sensitivity, specificity, positive predictive value, negative predictive value (NPV), and diagnostic accuracy were calculated, and paired statistical comparision were performed and statistical significance ( P < 0.05) was assessed for diagnostic outcomes. Inter-test agreement was evaluated using Cohen's κ-statistic.</p><p><strong>Results: </strong>FDA/EtBr microscopy demonstrated significantly higher sensitivity (94.4% vs. 88.9%; absolute increase 5.5%, P = 0.018) and higher diagnostic accuracy (91.0% vs. 86.7%; absolute increase 4.3%, P = 0.04) compared to ZN staining. While ZN staining showed marginally higher specificity (66.7% vs. 60.0%; P = 0.42), FDA/EtBr provided a significantly improved NPV (54.5% vs. 40.0%; absolute increase 14.5%, P = 0.03). Agreement with culture/DST was almost perfect for FDA/EtBr (κ = 0.85) and substantial for ZN staining (κ = 0.72).</p><p><strong>Conclusion: </strong>FDA/EtBr viability microscopy offers statistically significant improvements in sensitivity, NPV, and diagnostic accuracy over ZN staining in smear-positive pulmonary TB patients, supporting its prioritized use for treatment monitoring and programmatic decision-making in resource-limited, high-burden settings.</p>","PeriodicalId":14133,"journal":{"name":"International Journal of Mycobacteriology","volume":"15 2","pages":"95-103"},"PeriodicalIF":1.3000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Mycobacteriology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijmy.ijmy_243_25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ziehl-Neelsen (ZN) staining is routinely used for tuberculosis (TB) diagnosis, but cannot differentiate viable from nonviable bacilli. This limitation is particularly relevant in smear-positive pulmonary TB patients, where assessment of treatment response is essential. Fluorescein diacetate/ethidium bromide (FDA/EtBr) viability microscopy detects live Mycobacterium tuberculosis based on metabolic activity. This study compared the diagnostic performance of FDA/EtBr microscopy with ZN staining, using culture and drug susceptibility testing (DST) as the reference standard.

Methods: A cross-sectional study was conducted on 300 smear-positive pulmonary TB patients at Santosh Medical College, Ghaziabad, and National Institute of TB and Respiratory Diseases, New Delhi. After n-acetyl-l-cysteine-sodium hydroxide decontamination, sputum samples were examined using ZN staining, FDA/EtBr viability microscopy, and mycobacteria growth indicator tube 960 culture/DST. Sensitivity, specificity, positive predictive value, negative predictive value (NPV), and diagnostic accuracy were calculated, and paired statistical comparision were performed and statistical significance ( P < 0.05) was assessed for diagnostic outcomes. Inter-test agreement was evaluated using Cohen's κ-statistic.

Results: FDA/EtBr microscopy demonstrated significantly higher sensitivity (94.4% vs. 88.9%; absolute increase 5.5%, P = 0.018) and higher diagnostic accuracy (91.0% vs. 86.7%; absolute increase 4.3%, P = 0.04) compared to ZN staining. While ZN staining showed marginally higher specificity (66.7% vs. 60.0%; P = 0.42), FDA/EtBr provided a significantly improved NPV (54.5% vs. 40.0%; absolute increase 14.5%, P = 0.03). Agreement with culture/DST was almost perfect for FDA/EtBr (κ = 0.85) and substantial for ZN staining (κ = 0.72).

Conclusion: FDA/EtBr viability microscopy offers statistically significant improvements in sensitivity, NPV, and diagnostic accuracy over ZN staining in smear-positive pulmonary TB patients, supporting its prioritized use for treatment monitoring and programmatic decision-making in resource-limited, high-burden settings.

双醋酸荧光素/溴化乙锭活力显微镜与Ziehl-Neelsen染色快速诊断肺结核的比较评价。
背景:Ziehl-Neelsen (ZN)染色通常用于结核病(TB)的诊断,但不能区分活杆菌和非活杆菌。这一限制在痰检阳性肺结核患者中尤为重要,在这些患者中评估治疗反应至关重要。双醋酸荧光素/溴化乙锭(FDA/EtBr)活力显微镜根据代谢活性检测活的结核分枝杆菌。本研究以培养和药敏试验(DST)为参考标准,比较了锌染色下FDA/EtBr显微镜的诊断性能。方法:对加济阿巴德Santosh医学院和新德里国立结核病和呼吸系统疾病研究所的300名痰检阳性肺结核患者进行横断面研究。n-乙酰-l-半胱氨酸-氢氧化钠去污后,痰液样品采用ZN染色、FDA/EtBr活力显微镜和分枝杆菌生长指示管960培养/DST检测。计算灵敏度、特异度、阳性预测值、阴性预测值(NPV)、诊断准确率,并进行配对统计学比较,对诊断结果评价有统计学意义(P < 0.05)。试验间一致性采用Cohen的κ-统计量进行评价。结果:与ZN染色相比,FDA/EtBr镜检的灵敏度(94.4%比88.9%,绝对提高5.5%,P = 0.018)和诊断准确率(91.0%比86.7%,绝对提高4.3%,P = 0.04)均显著提高。虽然ZN染色的特异性略高(66.7% vs. 60.0%, P = 0.42),但FDA/EtBr染色的NPV显著提高(54.5% vs. 40.0%,绝对增加14.5%,P = 0.03)。FDA/EtBr染色与培养/DST几乎完全一致(κ = 0.85), ZN染色与培养/DST一致(κ = 0.72)。结论:与锌染色相比,FDA/EtBr活力显微镜在痰涂阳性肺结核患者的敏感性、NPV和诊断准确性方面具有统计学意义上的显著改善,支持其优先用于资源有限、高负担环境下的治疗监测和规划决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.20
自引率
25.00%
发文量
62
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书