Accuracy of a fluorescent dye-qPCR for diagnosis of pulmonary TB in HIV-associated adults.

IF 3.1
J H Reyna-Verdugo, J R Chávez-Méndez, J M Cornejo-Bravo, J Isaías de León-Ramírez, V A Reyes-Villegas, A Serrano-Medina, N A Castillo-Martínez
{"title":"Accuracy of a fluorescent dye-qPCR for diagnosis of pulmonary TB in HIV-associated adults.","authors":"J H Reyna-Verdugo, J R Chávez-Méndez, J M Cornejo-Bravo, J Isaías de León-Ramírez, V A Reyes-Villegas, A Serrano-Medina, N A Castillo-Martínez","doi":"10.5588/ijtld.25.0693","DOIUrl":null,"url":null,"abstract":"<p><p><sec><title>BACKGROUND</title>TB remains a major public health concern in Baja California, Mexico, where access to molecular diagnostics is limited.</sec><sec><title>METHODS</title>We evaluated the diagnostic performance of a fluorescent dye-based real-time quantitative PCR (SYBR-qPCR) assay targeting the IS6110 sequence for the detection of pulmonary TB (PTB). This was a cross-sectional diagnostic accuracy study conducted using sputum samples from 113 adults with clinical suspicion of PTB. Samples were analysed by acid-fast bacilli (AFB) smear microscopy, Löwenstein-Jensen culture as the reference standard, and SYBR-qPCR. Diagnostic performance was assessed using sensitivity, specificity, predictive values, and likelihood ratios. Receiver operating characteristic analysis was used to determine the optimal cycle threshold (Ct) cut-off.</sec><sec><title>RESULTS</title>SYBR-qPCR showed a sensitivity of 98.3% and a specificity of 92.5%. Sensitivity remained high among HIV-positive participants (96.6%), although specificity was lower (78.6%). In HIV-negative participants, both sensitivity and specificity exceeded 97%. The combination of SYBR-qPCR and AFB smear microscopy improved sensitivity (100%), and mean Ct values did not differ by HIV status.</sec><sec><title>CONCLUSION</title>SYBR-qPCR demonstrated consistent diagnostic performance across HIV strata, supporting its feasibility as a low-cost molecular tool for TB detection in resource-limited settings.</sec>.</p>","PeriodicalId":520801,"journal":{"name":"The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease","volume":"30 7","pages":"309-315"},"PeriodicalIF":3.1000,"publicationDate":"2026-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5588/ijtld.25.0693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUNDTB remains a major public health concern in Baja California, Mexico, where access to molecular diagnostics is limited.METHODSWe evaluated the diagnostic performance of a fluorescent dye-based real-time quantitative PCR (SYBR-qPCR) assay targeting the IS6110 sequence for the detection of pulmonary TB (PTB). This was a cross-sectional diagnostic accuracy study conducted using sputum samples from 113 adults with clinical suspicion of PTB. Samples were analysed by acid-fast bacilli (AFB) smear microscopy, Löwenstein-Jensen culture as the reference standard, and SYBR-qPCR. Diagnostic performance was assessed using sensitivity, specificity, predictive values, and likelihood ratios. Receiver operating characteristic analysis was used to determine the optimal cycle threshold (Ct) cut-off.RESULTSSYBR-qPCR showed a sensitivity of 98.3% and a specificity of 92.5%. Sensitivity remained high among HIV-positive participants (96.6%), although specificity was lower (78.6%). In HIV-negative participants, both sensitivity and specificity exceeded 97%. The combination of SYBR-qPCR and AFB smear microscopy improved sensitivity (100%), and mean Ct values did not differ by HIV status.CONCLUSIONSYBR-qPCR demonstrated consistent diagnostic performance across HIV strata, supporting its feasibility as a low-cost molecular tool for TB detection in resource-limited settings..

荧光染料qpcr诊断hiv相关成人肺结核的准确性
背景:在墨西哥下加利福尼亚州,结核病仍然是一个主要的公共卫生问题,在那里获得分子诊断的机会有限。方法应用基于荧光染料的实时荧光定量PCR (SYBR-qPCR)检测IS6110序列对肺结核(PTB)的诊断效果进行评价。这是一项横断面诊断准确性研究,使用了113名临床怀疑患有肺结核的成人的痰样本。采用抗酸杆菌(AFB)涂片镜检、Löwenstein-Jensen培养为对照品、SYBR-qPCR对样品进行分析。使用敏感性、特异性、预测值和似然比评估诊断性能。采用受者工作特性分析确定最佳周期阈值(Ct)截止。结果sybr - qpcr敏感性为98.3%,特异性为92.5%。尽管特异性较低(78.6%),但hiv阳性参与者的敏感性仍然很高(96.6%)。在hiv阴性参与者中,敏感性和特异性均超过97%。SYBR-qPCR和AFB涂片镜检的结合提高了灵敏度(100%),平均Ct值没有因HIV感染状况而差异。结论sybr - qpcr在HIV各层次均具有一致的诊断性能,支持其作为资源有限环境下低成本的结核病分子检测工具的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书