Correlation between ultrasonographic measurements of the ileum and serum cobalamin concentrations in healthy cats and cats with chronic gastrointestinal signs: A pilot study.

Brazilian journal of veterinary medicine Pub Date : 2026-06-26 eCollection Date: 2026-01-01 DOI:10.29374/2527-2179.bjvm000626
Iago Martins Oliveira, Letícia Oliveira Silva, Maria Eduarda Cardoso Cysneiros, Vitor Guimarães Ribeiro, Maria Fernanda Cavalcante Ramos
{"title":"Correlation between ultrasonographic measurements of the ileum and serum cobalamin concentrations in healthy cats and cats with chronic gastrointestinal signs: A pilot study.","authors":"Iago Martins Oliveira, Letícia Oliveira Silva, Maria Eduarda Cardoso Cysneiros, Vitor Guimarães Ribeiro, Maria Fernanda Cavalcante Ramos","doi":"10.29374/2527-2179.bjvm000626","DOIUrl":null,"url":null,"abstract":"<p><p>Assessing intestinal health in cats with chronic gastrointestinal signs remains challenging. Serum cobalamin concentration is commonly used as a marker of ileal dysfunction, whereas ultrasonography enables morphological evaluation of the gastrointestinal tract. This study investigated the correlation between ultrasonographic ileal wall thickness and serum cobalamin concentrations in healthy cats and cats with chronic gastrointestinal signs. Twelve cats were divided into a symptomatic group (G1, n = 6) and a healthy control group (G2, n = 6) and underwent laboratory testing and abdominal ultrasonography. Mean ileal thickness was slightly greater in G1 (0.22 ± 0.03 cm) than in G2 (0.21 ± 0.02 cm), although the difference was not statistically significant (p = 0.48). Serum cobalamin concentrations also did not differ significantly between groups (p = 0.81). Correlation analysis demonstrated a weak, nonsignificant positive correlation in G1 and a moderate, nonsignificant correlation in G2. These findings suggest that ileal thickness alone is not a reliable predictor of serum cobalamin concentration and highlight the need for multifactorial diagnostic approaches and studies with larger sample sizes.</p>","PeriodicalId":72458,"journal":{"name":"Brazilian journal of veterinary medicine","volume":"48 ","pages":"e000626"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13313039/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian journal of veterinary medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29374/2527-2179.bjvm000626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Assessing intestinal health in cats with chronic gastrointestinal signs remains challenging. Serum cobalamin concentration is commonly used as a marker of ileal dysfunction, whereas ultrasonography enables morphological evaluation of the gastrointestinal tract. This study investigated the correlation between ultrasonographic ileal wall thickness and serum cobalamin concentrations in healthy cats and cats with chronic gastrointestinal signs. Twelve cats were divided into a symptomatic group (G1, n = 6) and a healthy control group (G2, n = 6) and underwent laboratory testing and abdominal ultrasonography. Mean ileal thickness was slightly greater in G1 (0.22 ± 0.03 cm) than in G2 (0.21 ± 0.02 cm), although the difference was not statistically significant (p = 0.48). Serum cobalamin concentrations also did not differ significantly between groups (p = 0.81). Correlation analysis demonstrated a weak, nonsignificant positive correlation in G1 and a moderate, nonsignificant correlation in G2. These findings suggest that ileal thickness alone is not a reliable predictor of serum cobalamin concentration and highlight the need for multifactorial diagnostic approaches and studies with larger sample sizes.

健康猫和有慢性胃肠症状的猫回肠超声测量与血清钴胺素浓度的相关性:一项初步研究。
评估患有慢性胃肠症状的猫的肠道健康状况仍然具有挑战性。血清钴胺素浓度通常被用作回肠功能障碍的标志,而超声检查可以对胃肠道进行形态学评估。本研究探讨了健康猫和慢性胃肠症状猫回肠壁超声厚度与血清钴胺素浓度的相关性。将12只猫分为症状组(G1, n = 6)和健康对照组(G2, n = 6),进行实验室检查和腹部超声检查。G1组回肠平均厚度(0.22±0.03 cm)略大于G2组(0.21±0.02 cm),但差异无统计学意义(p = 0.48)。血清钴胺素浓度组间差异无统计学意义(p = 0.81)。相关分析显示,G1与G2之间存在弱的、不显著的正相关,而G2之间存在中度的、不显著的相关。这些发现表明,回肠厚度本身并不是血清钴胺素浓度的可靠预测指标,并强调需要多因素诊断方法和更大样本量的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书