Preserving Trabecular Bone Structure in Gross Specimens with Paraffin Wax for the Study of Osteoporosis.

Q4 Medicine
Journal of Plastination Pub Date : 2024-01-01 Epub Date: 2023-11-27 DOI:10.56507/brev5387
Marc A Pizzimenti, Xiaoliu Zhang, Jessica E Goetz, Punam K Saha
{"title":"Preserving Trabecular Bone Structure in Gross Specimens with Paraffin Wax for the Study of Osteoporosis.","authors":"Marc A Pizzimenti, Xiaoliu Zhang, Jessica E Goetz, Punam K Saha","doi":"10.56507/brev5387","DOIUrl":null,"url":null,"abstract":"<p><p>Analytical strategies to interpret computed tomography data for the study of osteoporosis require gross anatomical specimens that closely approximate the bone marrow matrix while maintaining the structural integrity of the trabecular network. Here we investigated if paraffin, gelatin-matrix, or silicone polymer impregnated bone specimens maintained the trabecular network and bone density of specimens used for comparative studies in osteoporosis. Distal tibia specimens (n = 12) from cadaveric human legs were used for this study. Multi-row detector computed tomography (MDCT) scans were completed on each specimen, with selected specimens re-scanned using micro-computed tomography (μCT), at different times to evaluate trabecular integrity. Once scanned, bones were de-marrowed using a solvent-based procedure. De-marrowed specimens were then impregnated, under vacuum controlled conditions, with either a silicone polymer, gelatin matrix solution, or paraffin wax, and re-scanned. μCT analysis demonstrated a high Pearson correlation coefficient in trabecular bone network area density between the native and de-marrowed states (r = 0.99). Quantitatively, paraffin impregnated specimens demonstrated the highest congruence in MCDT bone volume fraction (r = 0.92) and trabecular network area (r = 0.94) measures. These results were more robust in the μCT data (bone volume fraction, r = 0.97; and trabecular network area, r = 0.99). Additionally, of the impregnating procedures, paraffin wax provided the best qualitative specimens for handling, storage, and processing time. These data suggest that paraffin demonstrates a space occupying matrix that effectively protects the trabecular network and maintains the ability to quantify important biomechanical measures for assessing bone integrity. The preserved specimens will serve as standard models for comparison when developing algorithms for studying osteoporosis.</p>","PeriodicalId":36740,"journal":{"name":"Journal of Plastination","volume":"36 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13295180/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Plastination","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56507/brev5387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Analytical strategies to interpret computed tomography data for the study of osteoporosis require gross anatomical specimens that closely approximate the bone marrow matrix while maintaining the structural integrity of the trabecular network. Here we investigated if paraffin, gelatin-matrix, or silicone polymer impregnated bone specimens maintained the trabecular network and bone density of specimens used for comparative studies in osteoporosis. Distal tibia specimens (n = 12) from cadaveric human legs were used for this study. Multi-row detector computed tomography (MDCT) scans were completed on each specimen, with selected specimens re-scanned using micro-computed tomography (μCT), at different times to evaluate trabecular integrity. Once scanned, bones were de-marrowed using a solvent-based procedure. De-marrowed specimens were then impregnated, under vacuum controlled conditions, with either a silicone polymer, gelatin matrix solution, or paraffin wax, and re-scanned. μCT analysis demonstrated a high Pearson correlation coefficient in trabecular bone network area density between the native and de-marrowed states (r = 0.99). Quantitatively, paraffin impregnated specimens demonstrated the highest congruence in MCDT bone volume fraction (r = 0.92) and trabecular network area (r = 0.94) measures. These results were more robust in the μCT data (bone volume fraction, r = 0.97; and trabecular network area, r = 0.99). Additionally, of the impregnating procedures, paraffin wax provided the best qualitative specimens for handling, storage, and processing time. These data suggest that paraffin demonstrates a space occupying matrix that effectively protects the trabecular network and maintains the ability to quantify important biomechanical measures for assessing bone integrity. The preserved specimens will serve as standard models for comparison when developing algorithms for studying osteoporosis.

用石蜡保存大体标本的骨小梁结构以研究骨质疏松症。
在骨质疏松研究中,解释计算机断层扫描数据的分析策略需要大体解剖标本,这些标本与骨髓基质非常接近,同时保持小梁网络的结构完整性。在这里,我们研究了石蜡、明胶基质或硅树脂聚合物浸渍的骨标本是否保持了用于骨质疏松症比较研究的标本的小梁网络和骨密度。本研究使用的是来自人腿尸体的胫骨远端标本(n = 12)。每个标本完成多行计算机断层扫描(MDCT),并在不同时间使用微计算机断层扫描(μCT)重新扫描选定的标本,以评估小梁完整性。扫描后,骨骼用溶剂法去除骨髓。然后在真空控制条件下,用硅胶聚合物、明胶基质溶液或石蜡浸渍去骨髓标本,并重新扫描。μCT分析显示,原生状态和去骨髓状态的骨小梁网面积密度具有较高的Pearson相关系数(r = 0.99)。定量上,石蜡浸渍标本在MCDT骨体积分数(r = 0.92)和小梁网络面积(r = 0.94)测量上一致性最高。这些结果在μCT数据(骨体积分数,r = 0.97;小梁网络面积,r = 0.99)中更为稳健。此外,在浸渍过程中,石蜡为处理、储存和处理时间提供了最好的定性标本。这些数据表明,石蜡证明了一种占位基质,可以有效地保护小梁网络,并保持量化评估骨完整性的重要生物力学指标的能力。保存的标本将作为标准模型进行比较时,开发算法研究骨质疏松症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Plastination
Journal of Plastination Health Professions-Medical Laboratory Technology
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书