Evaluation of arteriovenous fistulas of obtuse anastomosis in reducing thrombosis using computational fluid dynamics.

IF 1.6 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Milad Rostami, Majid Abdolalinezhad, Mohsen Hashemi, Mohammad Amin Rahimi
{"title":"Evaluation of arteriovenous fistulas of obtuse anastomosis in reducing thrombosis using computational fluid dynamics.","authors":"Milad Rostami, Majid Abdolalinezhad, Mohsen Hashemi, Mohammad Amin Rahimi","doi":"10.1177/03913988261455782","DOIUrl":null,"url":null,"abstract":"<p><p>Arteriovenous fistula (AVF) failure in hemodialysis patients is strongly influenced by local hemodynamic factors such as elevated wall shear stress, flow separation, and vortex formation. In this study, computational fluid dynamics (CFD) simulations are performed to investigate the influence of anastomosis angle and blood rheology on AVF hemodynamics. Three non-Newtonian blood models (Carreau, power-law, and Casson) are first evaluated at 45°, 90°, and 135° anastomosis angles and validated against available experimental data. Based on shear stress prediction accuracy, the Carreau model is demonstrated as the best agreement and is selected for further simulations. Subsequently, AVFs with 45°, 90°, 110°, 120°, 135°, 145°, and 160° anastomosis angles are analyzed under maximum, medium, and minimum pulsatile flow conditions. Hemodynamic parameters including velocity patterns, wall shear stress distribution, vortex formation, and pressure drop between the proximal artery and vein are evaluated. Results indicate that increasing the anastomosis angle significantly reduces maximum wall shear stress, high-shear regions, vortex intensity, and pressure drop. Compared with the 45° configuration, the 160° angle reduced maximum shear stress by ~78% under peak flow conditions. Overall, obtuse anastomosis angles demonstrated improved hemodynamic performance, suggesting that larger angles may reduce thrombosis risk and cardiovascular burden in hemodialysis patients. Considering both hemodynamic performance and surgical feasibility, the 120° configuration is proposed as a clinically practical and effective option.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"520-535"},"PeriodicalIF":1.6000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988261455782","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Arteriovenous fistula (AVF) failure in hemodialysis patients is strongly influenced by local hemodynamic factors such as elevated wall shear stress, flow separation, and vortex formation. In this study, computational fluid dynamics (CFD) simulations are performed to investigate the influence of anastomosis angle and blood rheology on AVF hemodynamics. Three non-Newtonian blood models (Carreau, power-law, and Casson) are first evaluated at 45°, 90°, and 135° anastomosis angles and validated against available experimental data. Based on shear stress prediction accuracy, the Carreau model is demonstrated as the best agreement and is selected for further simulations. Subsequently, AVFs with 45°, 90°, 110°, 120°, 135°, 145°, and 160° anastomosis angles are analyzed under maximum, medium, and minimum pulsatile flow conditions. Hemodynamic parameters including velocity patterns, wall shear stress distribution, vortex formation, and pressure drop between the proximal artery and vein are evaluated. Results indicate that increasing the anastomosis angle significantly reduces maximum wall shear stress, high-shear regions, vortex intensity, and pressure drop. Compared with the 45° configuration, the 160° angle reduced maximum shear stress by ~78% under peak flow conditions. Overall, obtuse anastomosis angles demonstrated improved hemodynamic performance, suggesting that larger angles may reduce thrombosis risk and cardiovascular burden in hemodialysis patients. Considering both hemodynamic performance and surgical feasibility, the 120° configuration is proposed as a clinically practical and effective option.

应用计算流体动力学评价钝口吻合动静脉瘘减少血栓形成的作用。
血液透析患者动静脉瘘(AVF)失效受局部血流动力学因素的强烈影响,如壁面剪应力升高、血流分离、漩涡形成等。本研究采用计算流体动力学(CFD)模拟研究吻合角度和血液流变学对AVF血流动力学的影响。三种非牛顿血液模型(carcarau,幂律和Casson)首先在45°,90°和135°吻合角下进行评估,并根据现有的实验数据进行验证。基于剪切应力的预测精度,证明了Carreau模型是最符合剪切应力预测的模型,并被选择用于进一步的模拟。随后,分别对45°、90°、110°、120°、135°、145°和160°吻合角的avf在最大、中等和最小脉动流量条件下进行分析。血流动力学参数包括速度模式,壁剪切应力分布,涡流形成,近端动脉和静脉之间的压降进行评估。结果表明,增大吻合角可显著降低最大壁面剪应力、高剪切区、涡流强度和压降。在峰值流动条件下,与45°配置相比,160°配置使最大剪应力降低了约78%。综上所述,钝角吻合可改善血液动力学性能,提示较大的吻合角度可降低血液透析患者血栓形成风险和心血管负担。考虑到血流动力学性能和手术可行性,120°的配置被认为是临床实用和有效的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书