Accuracy and Variability of Spatial Localization of Infarct Core Predicted by CT Perfusion.

IF 1.4 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Inka K Berglar, Levin M Moser, Shervin Kamalian, Justin Vranic, Shahmir Kamalian, Sam Payabvash, Rehab N Khalid, Aman Patel, Christopher Stapleton, Aneesh B Singhal, Natalia S Rost, Ramon G Gonzalez, Pamela W Schaefer, Michael H Lev, Robert W Regenhardt, Rajiv Gupta
{"title":"Accuracy and Variability of Spatial Localization of Infarct Core Predicted by CT Perfusion.","authors":"Inka K Berglar, Levin M Moser, Shervin Kamalian, Justin Vranic, Shahmir Kamalian, Sam Payabvash, Rehab N Khalid, Aman Patel, Christopher Stapleton, Aneesh B Singhal, Natalia S Rost, Ramon G Gonzalez, Pamela W Schaefer, Michael H Lev, Robert W Regenhardt, Rajiv Gupta","doi":"10.1097/RCT.0000000000001884","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In patients with acute ischemic stroke, CT perfusion (CTP)-derived infarct core is valuable for prognostication, triage and transfer decision-making, and for informing studies of emerging therapeutic targets. In this study, we compare the accuracy and variability of the infarct core predicted by 2 FDA-cleared CTP programs, using diffusion-weighted MRI (DWI) as the reference standard.</p><p><strong>Methods: </strong>We analyzed 61 stroke patients who underwent admission CTP and DWI within 90 minutes. Infarct core was estimated using relative cerebral blood flow thresholds and compared with DWI-derived ground truth. After coregistration of CTP and DWI, Dice similarity coefficients were calculated to quantify the topographic concordance of the infarct core.</p><p><strong>Results: </strong>The CTP-determined infarct core volumes were significantly correlated with DWI but demonstrated substantial variability and bias. Our results showed limited topographic overlap, with median dice scores of 0.367 (CTP-A) and 0.289 (CTP-B). However, in patients with larger infarcts (volumes ≥50 mL), CTP provides more reliable estimates of spatial agreement, reaching median Dice scores of 0.61 (CTP-A) and 0.47 (CTP-B).</p><p><strong>Conclusions: </strong>Although these findings show a generally low accuracy of CTP estimation, they suggest that CTP may offer clinically meaningful insights for decision-making in the large-core setting and inform the design of future trials.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2026-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001884","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In patients with acute ischemic stroke, CT perfusion (CTP)-derived infarct core is valuable for prognostication, triage and transfer decision-making, and for informing studies of emerging therapeutic targets. In this study, we compare the accuracy and variability of the infarct core predicted by 2 FDA-cleared CTP programs, using diffusion-weighted MRI (DWI) as the reference standard.

Methods: We analyzed 61 stroke patients who underwent admission CTP and DWI within 90 minutes. Infarct core was estimated using relative cerebral blood flow thresholds and compared with DWI-derived ground truth. After coregistration of CTP and DWI, Dice similarity coefficients were calculated to quantify the topographic concordance of the infarct core.

Results: The CTP-determined infarct core volumes were significantly correlated with DWI but demonstrated substantial variability and bias. Our results showed limited topographic overlap, with median dice scores of 0.367 (CTP-A) and 0.289 (CTP-B). However, in patients with larger infarcts (volumes ≥50 mL), CTP provides more reliable estimates of spatial agreement, reaching median Dice scores of 0.61 (CTP-A) and 0.47 (CTP-B).

Conclusions: Although these findings show a generally low accuracy of CTP estimation, they suggest that CTP may offer clinically meaningful insights for decision-making in the large-core setting and inform the design of future trials.

CT灌注预测梗死核心空间定位的准确性和可变性。
目的:在急性缺血性脑卒中患者中,CT灌注(CTP)衍生的梗死核心对预后、分诊和转移决策以及对新出现的治疗靶点的研究具有重要价值。在这项研究中,我们比较了两个fda批准的CTP程序预测梗死核心的准确性和可变性,使用弥散加权MRI (DWI)作为参考标准。方法:对61例入院90分钟内行CTP和DWI检查的脑卒中患者进行分析。使用相对脑血流阈值估计梗死核心,并与dwi得出的基础真值进行比较。CTP和DWI共配准后,计算Dice相似系数,量化梗死核的地形一致性。结果:ctp测定的梗死核心体积与DWI显著相关,但表现出很大的变异性和偏倚。我们的结果显示地形重叠有限,骰子得分中位数为0.367 (CTP-A)和0.289 (CTP-B)。然而,对于较大梗死灶(容量≥50 mL)的患者,CTP提供了更可靠的空间一致性估计,中位Dice评分为0.61 (CTP- a)和0.47 (CTP- b)。结论:尽管这些发现表明CTP估计的准确性普遍较低,但它们表明CTP可能为大核心环境中的决策提供临床有意义的见解,并为未来试验的设计提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
230
审稿时长
4-8 weeks
期刊介绍: The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书