Assessment of the extremity exposure during preparation and administration of177Lu - results of a multi-center study.

IF 1.7 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Robert Kollaard, Łukasz Albiniak, Nicolas Cherbuin, Jérémie Dabin, Hanan Datz, Mahila Ferrari, Mikko Hakulinen, Sigalit Haruz-Waschitz, Tereza Kráčmerová, Ann McCann, Roel Wierts, Alessandra Zorz, Else Aalbersberg
{"title":"Assessment of the extremity exposure during preparation and administration of<sup>177</sup>Lu - results of a multi-center study.","authors":"Robert Kollaard, Łukasz Albiniak, Nicolas Cherbuin, Jérémie Dabin, Hanan Datz, Mahila Ferrari, Mikko Hakulinen, Sigalit Haruz-Waschitz, Tereza Kráčmerová, Ann McCann, Roel Wierts, Alessandra Zorz, Else Aalbersberg","doi":"10.1088/1361-6498/ae826f","DOIUrl":null,"url":null,"abstract":"<p><p>Despite the increased use of<sup>177</sup>Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of<sup>177</sup>Lu-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of<sup>177</sup>Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5<i>µ</i>Sv GBq<sup>-1</sup>(range 0.5-525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5<i>µ</i>Sv GBq<sup>-1</sup>) showed higher normalised ring doses than those using the gravity method (3.5<i>µ</i>Sv GBq<sup>-1</sup>) or a syringe pump (1.0<i>µ</i>Sv GBq<sup>-1</sup>). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1-136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during<sup>177</sup>Lu handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ae826f","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Despite the increased use of177Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of177Lu-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of177Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5µSv GBq-1(range 0.5-525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5µSv GBq-1) showed higher normalised ring doses than those using the gravity method (3.5µSv GBq-1) or a syringe pump (1.0µSv GBq-1). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1-136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during177Lu handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.

177Lu制备和给药过程中肢体暴露的评估——一项多中心研究的结果。
简介:尽管在过去的10年里,177Lu在核医学(NM)中的使用有所增加,但由于操纵这种药物而导致的肢体实际暴露的知识是有限的。本研究的目的是评估在广泛的纳米实践中,177lu标记的放射性药物在制备和给药过程中的肢体剂量。方法:全欧洲10个纳米中心的工作人员在制备和/或给药177lu标记的放射性药物时,在非惯用手的食指底部佩戴环形剂量计。收集了有关操纵活动、执行的任务和保护措施的信息,以便进行次级分析。结果与讨论:每个监测间隔的环剂量中位数为0.16 mSv,一个月内最大值为2.27 mSv。中位标准化剂量为3.5 μ Sv/GBq(范围0.5至525)。参与药物制备的工人的月剂量最高。手工给药(6.5 μ Sv/GBq)的工人比使用重力法(3.5 μ Sv/GBq)或注射泵(1.0 μ Sv/GBq)的工人显示出更高的标准化环剂量。在本研究中应用的不同技术和剂量计最低报告剂量的差异中,可以找到标准化环剂量范围大的解释。当使用指尖与戒指的剂量比为5来推断数据时,发现指尖的年剂量为1至136毫西弗,指尖的中位数剂量为每年10毫西弗。结论:177Lu处理期间的肢体暴露仍远低于剂量限值。最高标准剂量发生在制备和手动给药期间。总的来说,这项调查显示,在采取适当的辐射防护措施(例如屏蔽和尽量减少近距离接触时间)时,剂量仍然很低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书