Characterization of postmortem γ-hydroxybutyric acid (GHB) and a novel model to discern exogenous use.

IF 2.7 3区 医学 Q3 CHEMISTRY, ANALYTICAL
Sue Pearring, Simone Tchu, Brigitte Desharnais, Alexandra Doyon, Pascal Mireault, Simon Elliott, Luke N Rodda
{"title":"Characterization of postmortem γ-hydroxybutyric acid (GHB) and a novel model to discern exogenous use.","authors":"Sue Pearring, Simone Tchu, Brigitte Desharnais, Alexandra Doyon, Pascal Mireault, Simon Elliott, Luke N Rodda","doi":"10.1093/jat/bkag046","DOIUrl":null,"url":null,"abstract":"<p><p>Interpretation of postmortem (PM) γ-hydroxybutyric acid (GHB) remains challenging due to endogenous production and PM increases in concentration associated with decomposition. Existing interpretation guidelines primarily rely on a single criterion, such as concentration thresholds or urine-to-blood ratios. In San Francisco, routine and unbiased implementation of GHB testing across all casework generated a large dataset including 1865 GHB detections in PM blood or urine, of which 552 were paired peripheral blood and urine samples. Cases were categorized as acute exogenous use, confirmed exogenous use, or no indication of use based on toxicological and investigative findings. Peripheral blood concentrations in cases with no indication of use did not vary significantly by age, gender, race, or manner of death but were significantly higher in decomposed cases. While existing guidelines effectively identify endogenous levels, the proposed hybrid model, combining peripheral blood concentration (B) with urine-to-blood ratio (U/B), enables further classification into no exogenous use, possible exogenous use (B > 5 mg/L and U/B > -0.05 × B + 4), and acute exogenous use (B > 50 mg/L and U/B > -0.05 × B + 10). The model was evaluated and compared to existing guidelines. Internal applicability was assessed using recent casework, and external applicability was evaluated using an independent dataset from Québec, Canada. The hybrid model demonstrated improved performance, achieving substantially higher positive predictive value when compared to existing guidelines, while maintaining equal or improved performance measures across other metrics. This approach provides a conservative, evidence-based framework for distinguishing acute exogenous GHB use in PM casework.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2026-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkag046","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Interpretation of postmortem (PM) γ-hydroxybutyric acid (GHB) remains challenging due to endogenous production and PM increases in concentration associated with decomposition. Existing interpretation guidelines primarily rely on a single criterion, such as concentration thresholds or urine-to-blood ratios. In San Francisco, routine and unbiased implementation of GHB testing across all casework generated a large dataset including 1865 GHB detections in PM blood or urine, of which 552 were paired peripheral blood and urine samples. Cases were categorized as acute exogenous use, confirmed exogenous use, or no indication of use based on toxicological and investigative findings. Peripheral blood concentrations in cases with no indication of use did not vary significantly by age, gender, race, or manner of death but were significantly higher in decomposed cases. While existing guidelines effectively identify endogenous levels, the proposed hybrid model, combining peripheral blood concentration (B) with urine-to-blood ratio (U/B), enables further classification into no exogenous use, possible exogenous use (B > 5 mg/L and U/B > -0.05 × B + 4), and acute exogenous use (B > 50 mg/L and U/B > -0.05 × B + 10). The model was evaluated and compared to existing guidelines. Internal applicability was assessed using recent casework, and external applicability was evaluated using an independent dataset from Québec, Canada. The hybrid model demonstrated improved performance, achieving substantially higher positive predictive value when compared to existing guidelines, while maintaining equal or improved performance measures across other metrics. This approach provides a conservative, evidence-based framework for distinguishing acute exogenous GHB use in PM casework.

死后GHB的特征和一种识别外源性使用的新模型。
对死后γ -羟基丁酸(GHB)的解释仍然具有挑战性,因为其内源性产生和死后分解相关的浓度增加。现有的解释指南主要依赖于单一标准,如浓度阈值或尿血比。在旧金山,对所有病例进行常规和公正的GHB检测产生了一个大型数据集,其中包括1865例PM血液或尿液中的GHB检测,其中552例是外周血和尿液配对样本。根据毒理学和调查结果,病例分为急性外源性用药、确诊外源性用药或无使用指征。在没有使用适应症的病例中,外周血浓度没有因年龄、性别、种族或死亡方式而显著变化,但在腐烂的病例中,外周血浓度明显较高。虽然现有指南可以有效识别内源性水平,但本文提出的混合模型将外周血浓度(B)与尿血比(U/B)结合起来,可以进一步分类为无外源性使用、可能外源性使用(B > 5 mg/L和U/B > -0.05 × B + 4)和急性外源性使用(B > 50 mg/L和U/B > -0.05 × B + 10)。对该模型进行了评估并与现有指南进行了比较。内部适用性使用最近的案例工作进行评估,外部适用性使用来自加拿大qu忧郁的独立数据集进行评估。与现有的指导方针相比,混合模型证明了改进的性能,实现了更高的正预测值,同时在其他指标中保持相同或改进的性能度量。这种方法提供了一个保守的,以证据为基础的框架来区分急性外源性GHB在PM病例中的使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
20.00%
发文量
92
审稿时长
6-12 weeks
期刊介绍: The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation. Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书