{"title":"Defining Norms, Reliability, and Thresholds for Tone Burst-Induced Masseter Vestibular-Evoked Myogenic Potential Testing Through Bone Conduction.","authors":"Fathima Ruxana, Kumaran Thirunavukkarasu","doi":"10.7874/jao.2025.00423","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Masseter vestibular-evoked myogenic potentials (mVEMPs) provide a noninvasive approach for assessing saccular and vestibular nerve function. Although air-conducted stimuli are commonly used, bone-conduction stimulation offers advantages for individuals with conductive hearing loss. This study aimed to establish normative values and evaluate the test-retest reliability of BC-induced mVEMP using 500 Hz tone bursts in young adults. Subjects and.</p><p><strong>Methods: </strong>This normative study included 45 healthy participants (aged 18-35). Bone conduction mVEMPs were elicited using 500 Hz tone bursts delivered through a B71 RadioEar vibrator. Responses from the masseter muscle were recorded using surface electrodes placed in a zygomatic montage. Participants underwent two test sessions within 1 month. The assessed parameters included P1 and N1 latencies, peak-to-peak amplitude, and asymmetry ratio. Threshold estimation was performed on a subset of 15 participants to determine response detectability.</p><p><strong>Results: </strong>Normative values revealed consistent P1 and N1 latencies across sessions with mean latencies of 11.76 ms and 14.77 ms, respectively. No significant interaural or sex-related differences were noted, except for ipsilateral P1 latency and contralateral N1 latency. The test-retest reliability ranged from fair to good, particularly for the P1 latency and asymmetry ratio. Threshold responses were reliably elicited at intensities up to 115 dB SPL.</p><p><strong>Conclusions: </strong>Bone conduction mVEMP elicited stable and reproducible responses in healthy young adults, supporting its clinical utility, particularly in patients with conductive pathology, those with reduced neck muscle strength, and within geriatric populations.</p>","PeriodicalId":44886,"journal":{"name":"Journal of Audiology and Otology","volume":" ","pages":"189-197"},"PeriodicalIF":1.8000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13425013/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Audiology and Otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7874/jao.2025.00423","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and objectives: Masseter vestibular-evoked myogenic potentials (mVEMPs) provide a noninvasive approach for assessing saccular and vestibular nerve function. Although air-conducted stimuli are commonly used, bone-conduction stimulation offers advantages for individuals with conductive hearing loss. This study aimed to establish normative values and evaluate the test-retest reliability of BC-induced mVEMP using 500 Hz tone bursts in young adults. Subjects and.
Methods: This normative study included 45 healthy participants (aged 18-35). Bone conduction mVEMPs were elicited using 500 Hz tone bursts delivered through a B71 RadioEar vibrator. Responses from the masseter muscle were recorded using surface electrodes placed in a zygomatic montage. Participants underwent two test sessions within 1 month. The assessed parameters included P1 and N1 latencies, peak-to-peak amplitude, and asymmetry ratio. Threshold estimation was performed on a subset of 15 participants to determine response detectability.
Results: Normative values revealed consistent P1 and N1 latencies across sessions with mean latencies of 11.76 ms and 14.77 ms, respectively. No significant interaural or sex-related differences were noted, except for ipsilateral P1 latency and contralateral N1 latency. The test-retest reliability ranged from fair to good, particularly for the P1 latency and asymmetry ratio. Threshold responses were reliably elicited at intensities up to 115 dB SPL.
Conclusions: Bone conduction mVEMP elicited stable and reproducible responses in healthy young adults, supporting its clinical utility, particularly in patients with conductive pathology, those with reduced neck muscle strength, and within geriatric populations.
期刊介绍:
Journal of Audiology and Otology (JAO) (formerly known as Korean Journal of Audiology) aims to publish the most advanced findings for all aspects of the auditory and vestibular system and diseases of the ear using state-of-the-art techniques and analyses. The journal covers recent trends related to the topics of audiology, otology, and neurotology conducted by professionals, with the goal of providing better possible treatment to people of all ages, from infants to the elderly, who suffer from auditory and/or vestibular disorders and thus, improving their quality of life. This journal encourages the submission of review papers about current professional issues, research papers presenting a scientific base and clinical application, and case papers with unique reports or clinical trials. We also invite letters to the editor and papers related to the manufacture and distribution of medical devices. This journal provides integrated views from otologists, audiologists, and other healthcare practitioners, offering readers high quality scientific and clinical information. This peer-reviewed and open access journal has been the official journal of the Korean Audiological Society since 1997 and of both the Korean Audiological Society and the Korean Otological Society since 2017. It is published in English four times a year in January, April, July, and October.