Correction to “ASVCP Guidelines: Principles of Quality Assurance and Standards for Veterinary Clinical Pathology (Version 3.0)”

IF 1 4区 农林科学 Q3 VETERINARY SCIENCES
Veterinary clinical pathology Pub Date : 2026-10-21 Epub Date: 2026-06-23 DOI:10.1111/vcp.70130
{"title":"Correction to “ASVCP Guidelines: Principles of Quality Assurance and Standards for Veterinary Clinical Pathology (Version 3.0)”","authors":"","doi":"10.1111/vcp.70130","DOIUrl":null,"url":null,"abstract":"<p>\n <span>Arnold, J.E.</span>, <span>Camus, M.S.</span>, <span>Freeman, K.P.</span>, <span>Giori, L.</span>, <span>Hooijberg, E.H.</span>, <span>Jeffery, U.</span>, <span>Korchia, J.</span>, <span>Meindel, M.J.</span>, <span>Moore, A.R.</span>, <span>Sisson, S.C.</span>, <span>Vap, L.M.</span> and <span>Cook, J.R.</span> (<span>2019</span>), <span>ASVCP Guidelines: Principles of Quality Assurance and Standards for Veterinary Clinical Pathology (version 3.0)</span>. <i>Vet Clin Pathol</i>, <span>48</span>: <span>542</span>–<span>618</span>. https://doi.org/10.1111/vcp.12810\n </p><p>In the article cited above, the explanation of limit of quantification (LoQ) given in section 4.3.8.iv.3 (page 565) was misstated.</p><p>The correct text reads:</p><p>Limit of Quantification (LoQ) is the lowest amount of measurand that can be quantitatively determined with acceptable precision and trueness, under stated conditions [<span>1</span>]. It may be equal to or higher than the Limit of Detection (LOD) but will not be lower. There are multiple formulas in the literature that can be used to estimate LoQ [<span>2-4</span>]. These formulas compute a value used to verify that observed total error (TEo, calculated as bias + 2SD) is less than allowable total error (TEa). Multiple low concentration samples will need to be tested to determine the lowest measurand concentration at or closest to TEa.</p>","PeriodicalId":23593,"journal":{"name":"Veterinary clinical pathology","volume":"55 2","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2026-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/vcp.70130","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary clinical pathology","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/vcp.70130","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Arnold, J.E., Camus, M.S., Freeman, K.P., Giori, L., Hooijberg, E.H., Jeffery, U., Korchia, J., Meindel, M.J., Moore, A.R., Sisson, S.C., Vap, L.M. and Cook, J.R. (2019), ASVCP Guidelines: Principles of Quality Assurance and Standards for Veterinary Clinical Pathology (version 3.0). Vet Clin Pathol, 48: 542–618. https://doi.org/10.1111/vcp.12810

In the article cited above, the explanation of limit of quantification (LoQ) given in section 4.3.8.iv.3 (page 565) was misstated.

The correct text reads:

Limit of Quantification (LoQ) is the lowest amount of measurand that can be quantitatively determined with acceptable precision and trueness, under stated conditions [1]. It may be equal to or higher than the Limit of Detection (LOD) but will not be lower. There are multiple formulas in the literature that can be used to estimate LoQ [2-4]. These formulas compute a value used to verify that observed total error (TEo, calculated as bias + 2SD) is less than allowable total error (TEa). Multiple low concentration samples will need to be tested to determine the lowest measurand concentration at or closest to TEa.

更正“ASVCP指南:兽医临床病理学质量保证原则和标准(3.0版)”。
Arnold, j.e., Camus, m.s., Freeman, k.p., Giori, L., Hooijberg, e.h., Jeffery, U, Korchia, J., Meindel, m.j., Moore, a.r., Sisson, s.c., Vap, L.M.和Cook, J.R. (2019), ASVCP指南:兽医临床病理学质量保证原则和标准(3.0版)。兽医杂志,48:542-618。https://doi.org/10.1111/vcp.12810在上面引用的文章中,第4.3.8.iv.3节对定量限(LoQ)的解释(第565页)是错误的。正确的文字应该是:定量限(LoQ)是在规定的条件下,以可接受的精度和准确度定量确定的最低量。它可能等于或高于检测限(LOD),但不会低于。文献中有多个公式可用于估计LoQ[2-4]。这些公式计算一个值,用于验证观察到的总误差(TEo,计算为偏差+ 2SD)小于允许的总误差(TEa)。将需要检测多个低浓度样品,以确定在TEa或最接近TEa的最低测量浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary clinical pathology
Veterinary clinical pathology 农林科学-兽医学
CiteScore
1.70
自引率
16.70%
发文量
133
审稿时长
18-36 weeks
期刊介绍: Veterinary Clinical Pathology is the official journal of the American Society for Veterinary Clinical Pathology (ASVCP) and the European Society of Veterinary Clinical Pathology (ESVCP). The journal''s mission is to provide an international forum for communication and discussion of scientific investigations and new developments that advance the art and science of laboratory diagnosis in animals. Veterinary Clinical Pathology welcomes original experimental research and clinical contributions involving domestic, laboratory, avian, and wildlife species in the areas of hematology, hemostasis, immunopathology, clinical chemistry, cytopathology, surgical pathology, toxicology, endocrinology, laboratory and analytical techniques, instrumentation, quality assurance, and clinical pathology education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书