C1 pedicle screw placement risks in patients with ponticulus posticus: a CTA retrospective simulation study.

IF 3.8 3区 医学 Q1 ORTHOPEDICS
Ping Wang, Han Meng, Lifeng Yu, Ruipeng Zhang, Xinyu Song, Tiantian She, Dan Wang, Yuehua Li
{"title":"C1 pedicle screw placement risks in patients with ponticulus posticus: a CTA retrospective simulation study.","authors":"Ping Wang, Han Meng, Lifeng Yu, Ruipeng Zhang, Xinyu Song, Tiantian She, Dan Wang, Yuehua Li","doi":"10.1186/s13018-026-07046-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ponticulus posticus (POPO) may distort C1 surface landmarks for C1 pedicle screw (CPS) placement, raising concern for vertebral artery compromise (VAC). We aimed to establish a CTA-based workflow to identify POPO anatomies potentially suitable for CPS placement.</p><p><strong>Methods: </strong>This single-center retrospective CTA simulation study included 141 subjects: 46 bilateral POPO, 65 unilateral POPO, and 30 pure non-POPO patients. CPS trajectories were primarily simulated using PedicleScrewSimulator. D1 and D2 were analyzed as supra-arch and infra-arch localization variables. Ten morphometric parameters were measured; key safety metrics included D3 and D5. Simulated CPS feasibility and VAC were evaluated for 2.5-, 3.0-, 3.5-, and 4.0-mm screws. A side was considered geometrically feasible when D5 ≥ screw radius (r), D6/2 ≥ r, and D7/2 ≥ r. Simulated VAC was defined as violation of D5 or D7/2 clearance. Outcomes were analyzed using patient-clustered generalized estimating equations.</p><p><strong>Results: </strong>D1 and the D1-D2 shift differed markedly among groups (p < 0.001). D5 was smaller in bilateral POPO (2.93 ± 0.99 mm vs. 3.44 ± 1.14 mm vs. 3.81 ± 1.13 mm; p < 0.001). D3 did not differ significantly (p = 0.211). At 3.5 mm, overall simulated feasibility was 96.0%. Actual POPO sides showed 93.5% simulated feasibility and 6.5% simulated VAC, versus 99.2% and 0.8% in regular sides. In actual POPO sides, increasing diameter from 2.5 to 4.0 mm reduced simulated feasibility from 98.7% to 85.6% and increased VAC from 1.3% to 14.4%. The exploratory D3/D5 rule (D3 ≥ 3.4 mm and D5 ≥ 2.0 mm) achieved 88.4% sensitivity, 100% specificity, and 100% positive predictive value for avoiding simulated 3.5-mm VAC. Reliability for the four remeasured variables ranged from 0.702 to 0.799.</p><p><strong>Conclusions: </strong>CTA-based D3 and D5 thresholds can identify POPO anatomies potentially suitable for CPS placement, but simulation results reflect planning feasibility rather than validated operative safety. The D3 ≥ 3.4 mm and D5 ≥ 2.0 mm rule may serve as a conservative rule-in screening tool, pending clinical validation. POPO should not automatically preclude consideration of CPS but should trigger side-specific CTA analysis and conservative screw-diameter selection.</p>","PeriodicalId":16629,"journal":{"name":"Journal of Orthopaedic Surgery and Research","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2026-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13540833/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13018-026-07046-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ponticulus posticus (POPO) may distort C1 surface landmarks for C1 pedicle screw (CPS) placement, raising concern for vertebral artery compromise (VAC). We aimed to establish a CTA-based workflow to identify POPO anatomies potentially suitable for CPS placement.

Methods: This single-center retrospective CTA simulation study included 141 subjects: 46 bilateral POPO, 65 unilateral POPO, and 30 pure non-POPO patients. CPS trajectories were primarily simulated using PedicleScrewSimulator. D1 and D2 were analyzed as supra-arch and infra-arch localization variables. Ten morphometric parameters were measured; key safety metrics included D3 and D5. Simulated CPS feasibility and VAC were evaluated for 2.5-, 3.0-, 3.5-, and 4.0-mm screws. A side was considered geometrically feasible when D5 ≥ screw radius (r), D6/2 ≥ r, and D7/2 ≥ r. Simulated VAC was defined as violation of D5 or D7/2 clearance. Outcomes were analyzed using patient-clustered generalized estimating equations.

Results: D1 and the D1-D2 shift differed markedly among groups (p < 0.001). D5 was smaller in bilateral POPO (2.93 ± 0.99 mm vs. 3.44 ± 1.14 mm vs. 3.81 ± 1.13 mm; p < 0.001). D3 did not differ significantly (p = 0.211). At 3.5 mm, overall simulated feasibility was 96.0%. Actual POPO sides showed 93.5% simulated feasibility and 6.5% simulated VAC, versus 99.2% and 0.8% in regular sides. In actual POPO sides, increasing diameter from 2.5 to 4.0 mm reduced simulated feasibility from 98.7% to 85.6% and increased VAC from 1.3% to 14.4%. The exploratory D3/D5 rule (D3 ≥ 3.4 mm and D5 ≥ 2.0 mm) achieved 88.4% sensitivity, 100% specificity, and 100% positive predictive value for avoiding simulated 3.5-mm VAC. Reliability for the four remeasured variables ranged from 0.702 to 0.799.

Conclusions: CTA-based D3 and D5 thresholds can identify POPO anatomies potentially suitable for CPS placement, but simulation results reflect planning feasibility rather than validated operative safety. The D3 ≥ 3.4 mm and D5 ≥ 2.0 mm rule may serve as a conservative rule-in screening tool, pending clinical validation. POPO should not automatically preclude consideration of CPS but should trigger side-specific CTA analysis and conservative screw-diameter selection.

后桥患者放置C1椎弓根螺钉的风险:CTA回顾性模拟研究。
背景:在放置C1椎弓根螺钉(CPS)时,后Ponticulus (POPO)可能会扭曲C1表面标志,引起对椎动脉损伤(VAC)的关注。我们的目标是建立一个基于cta的工作流程,以确定可能适合CPS放置的POPO解剖结构。方法:这项单中心回顾性CTA模拟研究包括141例受试者:46例双侧POPO, 65例单侧POPO和30例单纯非POPO患者。CPS轨迹主要使用PedicleScrewSimulator进行模拟。D1和D2分别作为弓上和弓下定位变量进行分析。测量了10个形态学参数;主要安全指标包括D3和D5。对2.5 mm、3.0 mm、3.5 mm和4.0 mm螺钉进行模拟CPS可行性和VAC评估。当D5≥螺钉半径(r)、D6/2≥r、D7/2≥r时,认为A侧在几何上可行。模拟VAC定义为违反D5或D7/2间隙。使用患者聚类广义估计方程分析结果。结论:基于cta的D3和D5阈值可以识别可能适合CPS放置的POPO解剖结构,但模拟结果反映了计划的可行性,而不是验证了手术的安全性。D3≥3.4 mm和D5≥2.0 mm规则可作为保守规则筛选工具,有待临床验证。POPO不应自动排除CPS的考虑,但应触发特定侧位的CTA分析和保守的螺钉直径选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
7.70%
发文量
494
审稿时长
>12 weeks
期刊介绍: Journal of Orthopaedic Surgery and Research is an open access journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal issues. Orthopaedic research is conducted at clinical and basic science levels. With the advancement of new technologies and the increasing expectation and demand from doctors and patients, we are witnessing an enormous growth in clinical orthopaedic research, particularly in the fields of traumatology, spinal surgery, joint replacement, sports medicine, musculoskeletal tumour management, hand microsurgery, foot and ankle surgery, paediatric orthopaedic, and orthopaedic rehabilitation. The involvement of basic science ranges from molecular, cellular, structural and functional perspectives to tissue engineering, gait analysis, automation and robotic surgery. Implant and biomaterial designs are new disciplines that complement clinical applications. JOSR encourages the publication of multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines, which will be the trend in the coming decades.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书