Impact of Wearing a Face Mask on the Reliability of Standard Automated Perimetry in Glaucoma Patients and Suspects: a Retrospective Longitudinal Study.
Philip Keye, Julien Martin, Charlotte Evers, Daniel Böhringer, Thomas Reinhard, Jan Luebke
{"title":"Impact of Wearing a Face Mask on the Reliability of Standard Automated Perimetry in Glaucoma Patients and Suspects: a Retrospective Longitudinal Study.","authors":"Philip Keye, Julien Martin, Charlotte Evers, Daniel Böhringer, Thomas Reinhard, Jan Luebke","doi":"10.1055/a-2823-2534","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>PURPOSE: To assess the reliability of standard automated perimetry in a real-life cohort of glaucoma patients and suspects wearing face masks due to the COVID-19 pandemic in a large German eye hospital.</p><p><strong>Abstract: </strong>METHODS: Data of 160 eyes of 83 glaucoma patients and suspects who received at least one visual field examination and optical coherence tomography for glaucoma monitoring in 2018, 2019 and 2020 were included. Mean visual field defect and the rates of false-positive and false-negative responses between tests without (2019) and tests with a face mask (2020) were compared. Mean retinal nerve fibre layer thickness and the minimum rim width of Bruch's membrane opening served as a control for glaucoma progression.</p><p><strong>Abstract: </strong>RESULTS: No statistically significant difference between visual fields without a face mask, and examinations with a face mask could be detected for mean defect (p = 0.075), rate of false-positives (p = 0.7) and rate of false-negatives (p = 0.16).</p><p><strong>Abstract: </strong>CONCLUSION: Our data suggest that protective face mask wear does not impair the quality and reliability of standard automated perimetry in a real-life cohort of glaucoma patients and glaucoma suspects.</p>","PeriodicalId":17904,"journal":{"name":"Klinische Monatsblatter fur Augenheilkunde","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2026-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Klinische Monatsblatter fur Augenheilkunde","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2823-2534","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract: PURPOSE: To assess the reliability of standard automated perimetry in a real-life cohort of glaucoma patients and suspects wearing face masks due to the COVID-19 pandemic in a large German eye hospital.
Abstract: METHODS: Data of 160 eyes of 83 glaucoma patients and suspects who received at least one visual field examination and optical coherence tomography for glaucoma monitoring in 2018, 2019 and 2020 were included. Mean visual field defect and the rates of false-positive and false-negative responses between tests without (2019) and tests with a face mask (2020) were compared. Mean retinal nerve fibre layer thickness and the minimum rim width of Bruch's membrane opening served as a control for glaucoma progression.
Abstract: RESULTS: No statistically significant difference between visual fields without a face mask, and examinations with a face mask could be detected for mean defect (p = 0.075), rate of false-positives (p = 0.7) and rate of false-negatives (p = 0.16).
Abstract: CONCLUSION: Our data suggest that protective face mask wear does not impair the quality and reliability of standard automated perimetry in a real-life cohort of glaucoma patients and glaucoma suspects.
期刊介绍:
-Konzentriertes Fachwissen aus Klinik und Praxis:
Die entscheidenden Ergebnisse der internationalen Forschung - für Sie auf den Punkt gebracht und kritisch kommentiert,
Übersichtsarbeiten zu den maßgeblichen Themen der täglichen Praxis,
Top informiert - breite klinische Berichterstattung.
-CME-Punkte sammeln mit dem Refresher:
Effiziente, CME-zertifizierte Fortbildung, mit dem Refresher,
3 CME-Punkte pro Ausgabe - bis zu 36 CME-Punkte im Jahr!.
-Aktuelle Rubriken mit echtem Nutzwert:
Kurzreferate zu den wichtigsten Artikeln internationaler Zeitschriften,
Schwerpunktthema in jedem Heft: Ausführliche Übersichtsarbeiten zu den wichtigsten Themen der Ophthalmologie – so behalten Sie das gesamte Fach im Blick!,
Originalien mit den neuesten Entwicklungen,
Übersichten zu den relevanten Themen.