Accuracy of Key Sonographic Markers for Juxta-Articular Fractures

IF 2.1 4区 医学 Q2 ACOUSTICS
Journal of Ultrasound in Medicine Pub Date : 2026-10-13 Epub Date: 2026-06-23 DOI:10.1002/jum.70342
Xiaofang Fu MM, Lirong Liu PhD, Hao Sun MM, Changqin Sun MM, Qinhan Yang ME, Mengjie Dou MM, Duo Shi MM, Junpu Hu MM, Zhiming He BM, Guangquan Zhou PhD, Shiyu Jin MM, Faqin Lv MD
{"title":"Accuracy of Key Sonographic Markers for Juxta-Articular Fractures","authors":"Xiaofang Fu MM,&nbsp;Lirong Liu PhD,&nbsp;Hao Sun MM,&nbsp;Changqin Sun MM,&nbsp;Qinhan Yang ME,&nbsp;Mengjie Dou MM,&nbsp;Duo Shi MM,&nbsp;Junpu Hu MM,&nbsp;Zhiming He BM,&nbsp;Guangquan Zhou PhD,&nbsp;Shiyu Jin MM,&nbsp;Faqin Lv MD","doi":"10.1002/jum.70342","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To systematically evaluate sonographic features of long bone juxta-articular fractures and identify key diagnostic predictors using machine learning-based feature selection.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This prospective single-center diagnostic accuracy study enrolled 121 patients with clinically suspected juxta-articular fractures. Ten predefined sonographic features were assessed, with computed tomography (CT) serving as the reference standard. Key features were identified using shapley additive explanations (SHAP), and the 3 top-ranked features were used to construct a decision tree–based sonographic triad model, hereafter referred to as the sonographic triad model. This model generated a final binary ultrasound diagnosis for each suspected fracture site. Agreement between the final binary ultrasound diagnosis and CT was quantified using Cohen's κ with 95% confidence intervals (CIs). Inter-observer and intra-observer agreement was evaluated using blinded dual-reader review across the cohort. Diagnostic performance was quantified by sensitivity, specificity, predictive values, and the area under the receiver operating characteristic curve (AUC).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Analysis of 209 suspected juxta-articular fracture sites revealed that subcutaneous soft-tissue edema (88.5%), cortical separation (50.7%), and heterogeneous intra-articular effusion (56.9%) were the most prevalent findings. The SHAP analysis identified a specific predictive triad. The 3 primary predictors were subperiosteal hematoma (43.8% contribution), arc-shaped fracture end (28.3%), and heterogeneous intra-articular effusion (26.6%). These 3 features collectively accounted for 98.7% of the total feature importance and demonstrated high reproducibility, with good inter-observer agreement (κ = 0.833–0.980) and excellent intra-observer agreement (κ = 0.987–1.000). The final binary ultrasound diagnosis generated by the sonographic triad model demonstrated near-perfect agreement with CT at the suspected fracture-site level (κ = 0.904, 95% CI: 0.847–0.962). In addition, the sonographic triad model achieved excellent diagnostic performance, with a sensitivity of 93.0%, specificity of 97.2%, positive predictive value (PPV) of 96.8%, negative predictive value (NPV) of 93.8%, and an AUC of 0.966.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The sonographic triad model, based on subperiosteal hematoma, arc-shaped fracture end, and heterogeneous intra-articular effusion, demonstrated high diagnostic accuracy and strong concordance with CT for suspected juxta-articular long-bone fractures. This radiation-free and rapid approach may assist early screening and triage.</p>\n </section>\n </div>","PeriodicalId":17563,"journal":{"name":"Journal of Ultrasound in Medicine","volume":"45 11","pages":"2487-2498"},"PeriodicalIF":2.1000,"publicationDate":"2026-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jum.70342","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jum.70342","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To systematically evaluate sonographic features of long bone juxta-articular fractures and identify key diagnostic predictors using machine learning-based feature selection.

Methods

This prospective single-center diagnostic accuracy study enrolled 121 patients with clinically suspected juxta-articular fractures. Ten predefined sonographic features were assessed, with computed tomography (CT) serving as the reference standard. Key features were identified using shapley additive explanations (SHAP), and the 3 top-ranked features were used to construct a decision tree–based sonographic triad model, hereafter referred to as the sonographic triad model. This model generated a final binary ultrasound diagnosis for each suspected fracture site. Agreement between the final binary ultrasound diagnosis and CT was quantified using Cohen's κ with 95% confidence intervals (CIs). Inter-observer and intra-observer agreement was evaluated using blinded dual-reader review across the cohort. Diagnostic performance was quantified by sensitivity, specificity, predictive values, and the area under the receiver operating characteristic curve (AUC).

Results

Analysis of 209 suspected juxta-articular fracture sites revealed that subcutaneous soft-tissue edema (88.5%), cortical separation (50.7%), and heterogeneous intra-articular effusion (56.9%) were the most prevalent findings. The SHAP analysis identified a specific predictive triad. The 3 primary predictors were subperiosteal hematoma (43.8% contribution), arc-shaped fracture end (28.3%), and heterogeneous intra-articular effusion (26.6%). These 3 features collectively accounted for 98.7% of the total feature importance and demonstrated high reproducibility, with good inter-observer agreement (κ = 0.833–0.980) and excellent intra-observer agreement (κ = 0.987–1.000). The final binary ultrasound diagnosis generated by the sonographic triad model demonstrated near-perfect agreement with CT at the suspected fracture-site level (κ = 0.904, 95% CI: 0.847–0.962). In addition, the sonographic triad model achieved excellent diagnostic performance, with a sensitivity of 93.0%, specificity of 97.2%, positive predictive value (PPV) of 96.8%, negative predictive value (NPV) of 93.8%, and an AUC of 0.966.

Conclusions

The sonographic triad model, based on subperiosteal hematoma, arc-shaped fracture end, and heterogeneous intra-articular effusion, demonstrated high diagnostic accuracy and strong concordance with CT for suspected juxta-articular long-bone fractures. This radiation-free and rapid approach may assist early screening and triage.

关节旁骨折关键超声标记的准确性:一项使用可解释机器学习的前瞻性研究。
目的:系统评估长骨关节旁骨折的超声特征,并利用基于机器学习的特征选择识别关键的诊断预测因素。方法:本前瞻性单中心诊断准确性研究纳入121例临床疑似关节旁骨折的患者。评估10个预定义的超声特征,以计算机断层扫描(CT)作为参考标准。利用shapley加性解释(SHAP)识别关键特征,并利用排名前3位的特征构建基于决策树的超声三联征模型,以下简称超声三联征模型。该模型为每个疑似骨折部位生成最终的二元超声诊断。最终的二元超声诊断与CT之间的一致性使用95%置信区间(ci)的Cohen's κ进行量化。在整个队列中使用双读者盲法评价观察者之间和观察者内部的一致性。通过敏感性、特异性、预测值和受试者工作特征曲线下面积(AUC)来量化诊断效果。结果:对209例疑似关节旁骨折部位的分析显示,皮下软组织水肿(88.5%)、皮质分离(50.7%)和异质性关节内积液(56.9%)是最常见的表现。SHAP分析确定了一个特定的预测性三联征。3个主要预测因素为骨膜下血肿(43.8%)、弧形骨折端(28.3%)和异质性关节内积液(26.6%)。这3个特征合计占总特征重要性的98.7%,具有较高的再现性,观察者间一致性好(κ = 0.833-0.980),观察者内一致性好(κ = 0.987-1.000)。超声三联模型生成的最终二元超声诊断结果与CT在疑似骨折部位水平上接近完美吻合(κ = 0.904, 95% CI: 0.847-0.962)。此外,超声三联征模型具有优异的诊断性能,敏感性为93.0%,特异性为97.2%,阳性预测值(PPV)为96.8%,阴性预测值(NPV)为93.8%,AUC为0.966。结论:基于骨膜下血肿、骨折端呈弧形、关节内不均匀积液的超声三联模型对疑似关节旁长骨骨折具有较高的诊断准确性,与CT具有较强的一致性。这种无辐射和快速的方法可能有助于早期筛查和分诊。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
4.30%
发文量
205
审稿时长
1.5 months
期刊介绍: The Journal of Ultrasound in Medicine (JUM) is dedicated to the rapid, accurate publication of original articles dealing with all aspects of medical ultrasound, particularly its direct application to patient care but also relevant basic science, advances in instrumentation, and biological effects. The journal is an official publication of the American Institute of Ultrasound in Medicine and publishes articles in a variety of categories, including Original Research papers, Review Articles, Pictorial Essays, Technical Innovations, Case Series, Letters to the Editor, and more, from an international bevy of countries in a continual effort to showcase and promote advances in the ultrasound community. Represented through these efforts are a wide variety of disciplines of ultrasound, including, but not limited to: -Basic Science- Breast Ultrasound- Contrast-Enhanced Ultrasound- Dermatology- Echocardiography- Elastography- Emergency Medicine- Fetal Echocardiography- Gastrointestinal Ultrasound- General and Abdominal Ultrasound- Genitourinary Ultrasound- Gynecologic Ultrasound- Head and Neck Ultrasound- High Frequency Clinical and Preclinical Imaging- Interventional-Intraoperative Ultrasound- Musculoskeletal Ultrasound- Neurosonology- Obstetric Ultrasound- Ophthalmologic Ultrasound- Pediatric Ultrasound- Point-of-Care Ultrasound- Public Policy- Superficial Structures- Therapeutic Ultrasound- Ultrasound Education- Ultrasound in Global Health- Urologic Ultrasound- Vascular Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书