Interdigitated capacitive strain sensor enables precise yoga-inspired motion tracking.

npj Biosensing Pub Date : 2026-01-01 Epub Date: 2026-06-13 DOI:10.1038/s44328-026-00101-1
Maria Papaefstathiou, Mohamed Elgendi, Carlo Menon
{"title":"Interdigitated capacitive strain sensor enables precise yoga-inspired motion tracking.","authors":"Maria Papaefstathiou, Mohamed Elgendi, Carlo Menon","doi":"10.1038/s44328-026-00101-1","DOIUrl":null,"url":null,"abstract":"<p><p>We report a fully textile-based interdigitated capacitive (IDC) strain sensor for wearable posture recognition. The sensor is lightweight, comfortable, and washable, and maintained stable electromechanical performance during 6,500 strain cycles, with absolute value of the gauge factor ranging from 0.67 to 0.81 across the tested strain conditions. Integrated into clothing, the sensor captured multidimensional electrical responses, including capacitance-, resistance-, and phase-related signals, during four biomechanically distinct yoga postures: High Lunge, Lunge Forward, Squat, and Tree. Using a supervised machine-learning pipeline combining handcrafted sensor-channel features and MiniROCKET time-series features, record-level classification achieved an accuracy of 94.4% and a macro-averaged F1 score of 94.2%. Record-level five-fold cross-validation further showed stable performance across folds, supporting the robustness of the classification framework within the present controlled cohort. One-vs-rest receiver operating characteristic analysis yielded area under the curve values of 90%, 94%, 99%, and 99% for High Lunge, Lunge Forward, Squat, and Tree, respectively. Channel ablation analysis identified capacitance-derived features as the most informative predictors. Statistical and temporal analyses further showed posture-dependent differences in signal magnitude, normalized response, and waveform dynamics, while supervised low-dimensional projection revealed distinct class structure. These results demonstrate the feasibility of textile-based IDC sensing for wearable movement monitoring applications such as such digital fitness.</p>","PeriodicalId":501705,"journal":{"name":"npj Biosensing","volume":"3 1","pages":"39"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13282173/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Biosensing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s44328-026-00101-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We report a fully textile-based interdigitated capacitive (IDC) strain sensor for wearable posture recognition. The sensor is lightweight, comfortable, and washable, and maintained stable electromechanical performance during 6,500 strain cycles, with absolute value of the gauge factor ranging from 0.67 to 0.81 across the tested strain conditions. Integrated into clothing, the sensor captured multidimensional electrical responses, including capacitance-, resistance-, and phase-related signals, during four biomechanically distinct yoga postures: High Lunge, Lunge Forward, Squat, and Tree. Using a supervised machine-learning pipeline combining handcrafted sensor-channel features and MiniROCKET time-series features, record-level classification achieved an accuracy of 94.4% and a macro-averaged F1 score of 94.2%. Record-level five-fold cross-validation further showed stable performance across folds, supporting the robustness of the classification framework within the present controlled cohort. One-vs-rest receiver operating characteristic analysis yielded area under the curve values of 90%, 94%, 99%, and 99% for High Lunge, Lunge Forward, Squat, and Tree, respectively. Channel ablation analysis identified capacitance-derived features as the most informative predictors. Statistical and temporal analyses further showed posture-dependent differences in signal magnitude, normalized response, and waveform dynamics, while supervised low-dimensional projection revealed distinct class structure. These results demonstrate the feasibility of textile-based IDC sensing for wearable movement monitoring applications such as such digital fitness.

交叉数字电容应变传感器,使精确的瑜伽启发运动跟踪。
我们报告了一种用于可穿戴姿势识别的全基于纺织品的交叉数字电容(IDC)应变传感器。该传感器重量轻,舒适,可清洗,在6500个应变循环中保持稳定的机电性能,在测试的应变条件下,测量因子的绝对值范围为0.67至0.81。该传感器集成到服装中,在四种不同的生物力学瑜伽姿势:高弓步、前弓步、深蹲和树姿时,捕获多维电反应,包括电容、电阻和相位相关信号。使用结合手工制作的传感器通道特征和MiniROCKET时间序列特征的监督机器学习管道,记录级分类的准确率达到94.4%,宏观平均F1得分为94.2%。创纪录水平的五重交叉验证进一步显示了跨折叠的稳定性能,支持分类框架在当前对照队列中的稳健性。单对单的接受者操作特征分析得出,高弓步、前弓步、深蹲和原地踏步的曲线下面积分别为90%、94%、99%和99%。通道消融分析确定电容衍生特征是最具信息量的预测因子。统计分析和时间分析进一步显示了姿态相关的信号强度、归一化响应和波形动态差异,而监督低维投影显示了明显的类结构。这些结果证明了基于纺织品的IDC传感用于可穿戴运动监测应用(如数字健身)的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书