Added value of photon-counting CT for triple rule-out imaging: A propensity-matched comparison with energy-integrating CT.

Sardi Hyska, Milán Vecsey-Nagy, Tilman Emrich, José Osoria-Velasquez, Moritz C Halfmann, Jens Ricke, Nicola Fink, Fabian Bamberg, Ismail Mikdat Kabakus, Pál Maurovich-Horvat, Akos Varga-Szemes, Muhammad Taha Hagar
{"title":"Added value of photon-counting CT for triple rule-out imaging: A propensity-matched comparison with energy-integrating CT.","authors":"Sardi Hyska, Milán Vecsey-Nagy, Tilman Emrich, José Osoria-Velasquez, Moritz C Halfmann, Jens Ricke, Nicola Fink, Fabian Bamberg, Ismail Mikdat Kabakus, Pál Maurovich-Horvat, Akos Varga-Szemes, Muhammad Taha Hagar","doi":"10.1016/j.jcct.2026.06.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the technical performance of photon-counting detector (PCD)-CT and energy-integrating detector (EID)-CT in triple rule-out (TRO) imaging.</p><p><strong>Methods: </strong>In this IRB-approved single-center study, consecutive TRO-CT patients underwent dual-source EID-CT or PCD-CT with 75 or 98.5 ​mL iopromide. Propensity score matching generated four groups: EID-75, EID-98.5, PCD-75 and PCD-98.5. Axial polychromatic images were reconstructed at 1.0 ​mm for whole-thorax and 0.6 ​mm for coronary assessment using a vascular kernel (Bv36). Volume CT dose index (CTDI<sub>vol</sub>), contrast-to-noise ratio (CNR), and diagnostic confidence (Likert 4, excellent) were compared across vascular territories. Diagnostic performance for coronary stenosis was assessed in patients undergoing invasive coronary angiography.</p><p><strong>Results: </strong>A total of 96 subjects (mean age 62.0 ​± ​13.1 years; 62.5% female, n ​= ​24 per group) were included. TRO-CT ruled out aortic, coronary and pulmonary pathology in 69/96 (71.9%) patients. PCD-CT showed 32.3% lower CTDIvol than EID-CT (29.3 [23.5-41.4] vs 43.3 [36.6-51.0] mGy; p ​< ​0.001). PCD-98.5 yielded the highest CNR (aorta, 32.2 [25.5-44.1]; coronaries, 24.5 [19.5-31.3]; and pulmonary arteries, 36.8 [28.0-45.3]; all p ​< ​0.001). Pulmonary CNR with PCD-75 was comparable to EID-98.5 despite lower contrast volume (22.4 [19.1-28.8] vs 24.2 [20.3-29.6]; p ​= ​0.437). Segmental pulmonary diagnostic confidence increased from fair (2 [1-3]) with EID-98.5 to excellent (4 [3-4]) with PCD-98.5 (p ​< ​0.001). TRO-CT showed coronary segment-based sensitivity of 94.4% (17/18) and specificity of 93.2% (218/234), with no AUC difference between EID-CT and PCD-CT (0.961 vs 0.936; p ​= ​0.361).</p><p><strong>Conclusion: </strong>PCD-CT enabled robust TRO imaging with lower radiation dose, higher multi-territory CNR, and greater segmental pulmonary diagnostic confidence, addressing key limitations of conventional TRO protocols.</p>","PeriodicalId":94071,"journal":{"name":"Journal of cardiovascular computed tomography","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiovascular computed tomography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.jcct.2026.06.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the technical performance of photon-counting detector (PCD)-CT and energy-integrating detector (EID)-CT in triple rule-out (TRO) imaging.

Methods: In this IRB-approved single-center study, consecutive TRO-CT patients underwent dual-source EID-CT or PCD-CT with 75 or 98.5 ​mL iopromide. Propensity score matching generated four groups: EID-75, EID-98.5, PCD-75 and PCD-98.5. Axial polychromatic images were reconstructed at 1.0 ​mm for whole-thorax and 0.6 ​mm for coronary assessment using a vascular kernel (Bv36). Volume CT dose index (CTDIvol), contrast-to-noise ratio (CNR), and diagnostic confidence (Likert 4, excellent) were compared across vascular territories. Diagnostic performance for coronary stenosis was assessed in patients undergoing invasive coronary angiography.

Results: A total of 96 subjects (mean age 62.0 ​± ​13.1 years; 62.5% female, n ​= ​24 per group) were included. TRO-CT ruled out aortic, coronary and pulmonary pathology in 69/96 (71.9%) patients. PCD-CT showed 32.3% lower CTDIvol than EID-CT (29.3 [23.5-41.4] vs 43.3 [36.6-51.0] mGy; p ​< ​0.001). PCD-98.5 yielded the highest CNR (aorta, 32.2 [25.5-44.1]; coronaries, 24.5 [19.5-31.3]; and pulmonary arteries, 36.8 [28.0-45.3]; all p ​< ​0.001). Pulmonary CNR with PCD-75 was comparable to EID-98.5 despite lower contrast volume (22.4 [19.1-28.8] vs 24.2 [20.3-29.6]; p ​= ​0.437). Segmental pulmonary diagnostic confidence increased from fair (2 [1-3]) with EID-98.5 to excellent (4 [3-4]) with PCD-98.5 (p ​< ​0.001). TRO-CT showed coronary segment-based sensitivity of 94.4% (17/18) and specificity of 93.2% (218/234), with no AUC difference between EID-CT and PCD-CT (0.961 vs 0.936; p ​= ​0.361).

Conclusion: PCD-CT enabled robust TRO imaging with lower radiation dose, higher multi-territory CNR, and greater segmental pulmonary diagnostic confidence, addressing key limitations of conventional TRO protocols.

光子计数CT对三重排除成像的附加价值:与能量积分CT的倾向匹配比较。
目的:比较光子计数检测器(PCD)-CT与能量积分检测器(EID)-CT在三重排除(TRO)成像中的技术性能。方法:在这项经irb批准的单中心研究中,连续TRO-CT患者使用75或98.5 mL碘丙胺进行双源EID-CT或PCD-CT。倾向评分匹配生成四组:EID-75、EID-98.5、PCD-75和PCD-98.5。利用血管核(Bv36)重建全胸1.0 mm和冠状动脉0.6 mm的轴向多色图像。体积CT剂量指数(CTDIvol)、噪声对比比(CNR)和诊断置信度(Likert 4,优秀)在不同血管区域进行比较。在接受有创冠状动脉造影的患者中评估冠状动脉狭窄的诊断性能。结果:共纳入96例患者,平均年龄62.0±13.1岁,女性62.5%,每组24例。69/96(71.9%)患者的TRO-CT排除了主动脉、冠状动脉和肺部病变。PCD-CT显示CTDIvol比EID-CT低32.3% (29.3 [23.5-41.4]vs 43.3 [36.6-51.0] mGy; p < 0.001)。PCD-98.5的CNR最高(主动脉32.2[25.5-44.1],冠状动脉24.5[19.5-31.3],肺动脉36.8[28.0-45.3],均p < 0.001)。PCD-75组肺CNR与EID-98.5相当,尽管对比体积较低(22.4 [19.1-28.8]vs 24.2 [20.3-29.6]; p = 0.437)。肺节段性诊断置信度从EID-98.5的一般(2[1-3])增加到PCD-98.5的优异(4 [3-4])(p < 0.001)。TRO-CT基于冠状动脉段的敏感性为94.4%(17/18),特异性为93.2% (218/234),EID-CT与PCD-CT AUC无差异(0.961 vs 0.936; p = 0.361)。结论:PCD-CT具有较低的放射剂量、较高的多区域CNR和更高的肺节段性诊断可信度,解决了传统TRO方案的主要局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书