Simultaneous T2, T2*, and R2' Mapping for Multiple Sclerosis Using Nonlinear Model-Based Reconstruction of Undersampled Radial RARE-EPI MRI.

IF 3.2 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Magnetic Resonance in Medicine Pub Date : 2026-10-01 Epub Date: 2026-06-18 DOI:10.1002/mrm.70465
Jose Raul Velasquez Vides, Carl J J Herrmann, Thomas Gladytz, Hoby P Hetherington, Hendrik Mattern, Xiaoqing Wang, Jason M Millward, Shahriar Shalikar, Igor Fabian Tellez Ceja, Beate Endemann, Sonia Waiczies, Joseph Kuchling, Friedemann Paul, Georg Rose, Min-Chi Ku, Franz Schmitt, Thoralf Niendorf
{"title":"Simultaneous T<sub>2</sub>, T<sub>2</sub>*, and R<sub>2</sub>' Mapping for Multiple Sclerosis Using Nonlinear Model-Based Reconstruction of Undersampled Radial RARE-EPI MRI.","authors":"Jose Raul Velasquez Vides, Carl J J Herrmann, Thomas Gladytz, Hoby P Hetherington, Hendrik Mattern, Xiaoqing Wang, Jason M Millward, Shahriar Shalikar, Igor Fabian Tellez Ceja, Beate Endemann, Sonia Waiczies, Joseph Kuchling, Friedemann Paul, Georg Rose, Min-Chi Ku, Franz Schmitt, Thoralf Niendorf","doi":"10.1002/mrm.70465","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To demonstrate the synergy of undersampled radial 2in1-RARE-EPI acquisition and nonlinear model-based reconstruction for accelerated and simultaneous T<sub>2</sub>, T<sub>2</sub>*, and R<sub>2</sub>' mapping in brains of patients with multiple sclerosis (MS).</p><p><strong>Methods: </strong>2in1-RARE-EPI combines a RARE module with an EPI module to capture T<sub>2</sub> and T<sub>2</sub>* information. Nonlinear model-based reconstruction was applied to estimate T<sub>2</sub>, T<sub>2</sub>* maps directly from undersampled k-space data. A retrospective undersampling experiment was conducted to compare nonlinear model-based and parallel imaging compressed sensing (PICS) reconstruction. The proposed approach was validated and compared to reference methods multiecho spin-echo (T<sub>2</sub>, MSE) and multiecho gradient-echo (T<sub>2</sub>*, MGRE) in a phantom, healthy subjects, and MS patients.</p><p><strong>Results: </strong>2in1-RARE-EPI together with nonlinear model-based reconstruction enabled T<sub>2</sub>, T<sub>2</sub>*, and R<sub>2</sub>' mapping with 7.5-fold scan-time acceleration relative to the references, while addressing key limitations of reference techniques, including long acquisition times, misregistration, motion and off-resonance sensitivity, and the need for calibration scans. Phantom and in vivo validation showed that the parametric maps obtained with this approach were in agreement with the reference methods. Compared with PICS, nonlinear model-based reconstruction showed more consistent spatial detail and accuracy at higher acceleration factors. The proposed method detected small focal lesions in T<sub>2</sub>, T<sub>2</sub>*, and R<sub>2</sub>' maps of MS patients and enabled visualization of the central vein sign.</p><p><strong>Conclusion: </strong>Scan time reduction facilitated by nonlinear model-based reconstruction of 2in1-RARE-EPI provides a technical foundation for enhanced patient compliance, and is a fundamental precursor for broader clinical studies on the potential of T<sub>2</sub>, T<sub>2</sub>*, and R<sub>2</sub>' as imaging biomarkers.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":"1872-1892"},"PeriodicalIF":3.2000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13419268/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.70465","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/18 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To demonstrate the synergy of undersampled radial 2in1-RARE-EPI acquisition and nonlinear model-based reconstruction for accelerated and simultaneous T2, T2*, and R2' mapping in brains of patients with multiple sclerosis (MS).

Methods: 2in1-RARE-EPI combines a RARE module with an EPI module to capture T2 and T2* information. Nonlinear model-based reconstruction was applied to estimate T2, T2* maps directly from undersampled k-space data. A retrospective undersampling experiment was conducted to compare nonlinear model-based and parallel imaging compressed sensing (PICS) reconstruction. The proposed approach was validated and compared to reference methods multiecho spin-echo (T2, MSE) and multiecho gradient-echo (T2*, MGRE) in a phantom, healthy subjects, and MS patients.

Results: 2in1-RARE-EPI together with nonlinear model-based reconstruction enabled T2, T2*, and R2' mapping with 7.5-fold scan-time acceleration relative to the references, while addressing key limitations of reference techniques, including long acquisition times, misregistration, motion and off-resonance sensitivity, and the need for calibration scans. Phantom and in vivo validation showed that the parametric maps obtained with this approach were in agreement with the reference methods. Compared with PICS, nonlinear model-based reconstruction showed more consistent spatial detail and accuracy at higher acceleration factors. The proposed method detected small focal lesions in T2, T2*, and R2' maps of MS patients and enabled visualization of the central vein sign.

Conclusion: Scan time reduction facilitated by nonlinear model-based reconstruction of 2in1-RARE-EPI provides a technical foundation for enhanced patient compliance, and is a fundamental precursor for broader clinical studies on the potential of T2, T2*, and R2' as imaging biomarkers.

基于非线性模型的欠采样径向RARE-EPI MRI重建多发性硬化症T2, T2*和R2'同时映射。
目的:探讨欠采样径向2in1-RARE-EPI采集与基于非线性模型的重建在多发性硬化症(MS)患者大脑中加速、同步绘制T2、T2*和R2'图谱的协同作用。方法:2in1-RARE-EPI结合RARE模块和EPI模块采集T2和T2*信息。基于非线性模型的重构直接从欠采样k空间数据中估计T2, T2*映射。回顾性欠采样实验比较了基于非线性模型和并行图像压缩感知(PICS)的重建。在幻影、健康受试者和MS患者中验证了该方法,并与参考方法多回波自旋回波(T2, MSE)和多回波梯度回波(T2*, MGRE)进行了比较。结果:2in1-RARE-EPI与基于非线性模型的重建一起,使T2、T2*和R2'的映射相对于参考文献具有7.5倍的扫描时间加速,同时解决了参考技术的关键限制,包括采集时间长、配准错误、运动和非共振灵敏度,以及需要校准扫描。模型和体内验证表明,该方法得到的参数图与参考方法一致。与PICS相比,在较高的加速度因子下,基于非线性模型的重建具有更一致的空间细节和精度。该方法在MS患者的T2、T2*和R2'图中检测到小的局灶性病变,实现了中心静脉征象的可视化。结论:基于非线性模型的2in1-RARE-EPI重建减少了扫描时间,为提高患者依从性提供了技术基础,是T2、T2*和R2’作为成像生物标志物潜力的更广泛临床研究的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书