{"title":"GPT-4.1 and Llama 3.3 70 fail to detect clinically relevant errors in radiology reports in zero-shot evaluation.","authors":"Tugba Akinci D'Antonoli, Lisa C Adams, Jannik Lübberstedt, Markus M Graf, Christian J Mertens, Felix Busch, Sebastian Ziegelmayer, Marcus R Makowski, Keno Bressem, Ina Luiken","doi":"10.1007/s00330-026-12697-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate whether GPT-4.1 and Llama 3.3 70B, large language models (LLMs) assessed in zero-shot, baseline configurations, detect and categorize clinically consequential errors across types that range from pattern-based to reasoning-dependent.</p><p><strong>Materials and methods: </strong>Two hundred fifty-six radiology reports encompassing CT (n = 104), MRI (n = 104), and X-ray (n = 48) studies across multiple anatomical regions were retrospectively analyzed. For each original report, four variants (n = 1024) were generated, each incorporating one of four predefined error types: E1, anatomical mislabeling that could cause wrong-site actions; E2, physiologically impossible or nonsensical findings; E3, diagnostic inconsistencies that affect staging or diagnosis; E4, inappropriate recommendations. The evaluated models were GPT‑4.1 04-14) and Llama 3.3 70B, both used without domain-specific training or prompt optimization to assess baseline model performance.</p><p><strong>Results: </strong>Model performance revealed a systematic hierarchy governed by error type and imaging modality. Physiologically impossible errors (E2) showed the lowest performance: 46.2% (CT) and 33.7% (MRI) for GPT-4.1, compared with 32.7% and 25.0% for Llama 3.3, respectively. Overall success for GPT-4.1 on E2 was 16.3% (CT), 8.7% (MRI), and 12.5% (X-ray). Mislabeling errors (E1) were detected in 49.0% by GPT‑4.1 and 33.7% by Llama 3.3 for MRI. Best performance occurred for inappropriate recommendations (E4), with GPT‑4.1 achieving 85.4% detection in X-ray with high classification accuracy.</p><p><strong>Conclusion: </strong>The evaluation framework and benchmark dataset provide a methodology for assessing LLM performance on clinically significant errors. Applied to GPT-4.1 and Llama 3.3 70B in zero-shot settings, the framework reveals a performance gap between pattern-based and reasoning-dependent error detection that warrants investigation across additional models and optimization strategies.</p><p><strong>Key points: </strong>Question LLMs are increasingly used for quality assurance of radiology reports, but whether their linguistic competence translates into the detection of clinically significant errors remains unclear. Findings Error detection was type-dependent, both GPT-4.1 and Llama 3.3 70B performed poorly on physiologic and anatomical errors, but better on inappropriate recommendations. Clinical relevance LLMs failed to detect most clinically consequential errors in radiology reports, especially physiologically impossible statements that trained radiologists would rapidly identify.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":"8149-8159"},"PeriodicalIF":6.0000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13661699/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-026-12697-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate whether GPT-4.1 and Llama 3.3 70B, large language models (LLMs) assessed in zero-shot, baseline configurations, detect and categorize clinically consequential errors across types that range from pattern-based to reasoning-dependent.

Materials and methods: Two hundred fifty-six radiology reports encompassing CT (n = 104), MRI (n = 104), and X-ray (n = 48) studies across multiple anatomical regions were retrospectively analyzed. For each original report, four variants (n = 1024) were generated, each incorporating one of four predefined error types: E1, anatomical mislabeling that could cause wrong-site actions; E2, physiologically impossible or nonsensical findings; E3, diagnostic inconsistencies that affect staging or diagnosis; E4, inappropriate recommendations. The evaluated models were GPT‑4.1 04-14) and Llama 3.3 70B, both used without domain-specific training or prompt optimization to assess baseline model performance.

Results: Model performance revealed a systematic hierarchy governed by error type and imaging modality. Physiologically impossible errors (E2) showed the lowest performance: 46.2% (CT) and 33.7% (MRI) for GPT-4.1, compared with 32.7% and 25.0% for Llama 3.3, respectively. Overall success for GPT-4.1 on E2 was 16.3% (CT), 8.7% (MRI), and 12.5% (X-ray). Mislabeling errors (E1) were detected in 49.0% by GPT‑4.1 and 33.7% by Llama 3.3 for MRI. Best performance occurred for inappropriate recommendations (E4), with GPT‑4.1 achieving 85.4% detection in X-ray with high classification accuracy.

Conclusion: The evaluation framework and benchmark dataset provide a methodology for assessing LLM performance on clinically significant errors. Applied to GPT-4.1 and Llama 3.3 70B in zero-shot settings, the framework reveals a performance gap between pattern-based and reasoning-dependent error detection that warrants investigation across additional models and optimization strategies.

Key points: Question LLMs are increasingly used for quality assurance of radiology reports, but whether their linguistic competence translates into the detection of clinically significant errors remains unclear. Findings Error detection was type-dependent, both GPT-4.1 and Llama 3.3 70B performed poorly on physiologic and anatomical errors, but better on inappropriate recommendations. Clinical relevance LLMs failed to detect most clinically consequential errors in radiology reports, especially physiologically impossible statements that trained radiologists would rapidly identify.

GPT-4.1和Llama 3.3 70在零射击评估中未能发现放射学报告中的临床相关错误。
目的:评估GPT-4.1和Llama 3.3 70B,大型语言模型(LLMs)是否在零射击,基线配置中评估,检测和分类临床后果错误,范围从基于模式到依赖推理。材料和方法:回顾性分析256份放射学报告,包括CT (n = 104)、MRI (n = 104)和x射线(n = 48)在多个解剖区域的研究。对于每个原始报告,生成了四个变体(n = 1024),每个变体都包含四种预定义错误类型中的一种:E1,可能导致错误位点动作的解剖错误标记;E2,生理上不可能或无意义的发现;E3,影响分期或诊断的诊断不一致;E4,不恰当的建议。被评估的模型是GPT - 4.1 04-14)和Llama 3.3 70B,两者都没有经过特定领域的训练或快速优化来评估基线模型性能。结果:模型性能显示出由误差类型和成像方式控制的系统层次结构。生理不可能误差(E2)表现最低:GPT-4.1组为46.2% (CT)和33.7% (MRI),而Llama 3.3组分别为32.7%和25.0%。GPT-4.1治疗E2的总成功率分别为16.3% (CT)、8.7% (MRI)和12.5% (x线)。MRI的GPT - 4.1和Llama 3.3分别检测出49.0%和33.7%的误标错误(E1)。最佳表现出现在不适当的推荐(E4)中,GPT - 4.1在x射线中达到85.4%的检出率,分类准确率很高。结论:评估框架和基准数据集为评估LLM在临床重大错误方面的表现提供了一种方法。该框架应用于GPT-4.1和Llama 3.3 70B的零射设置中,揭示了基于模式和依赖推理的错误检测之间的性能差距,需要对其他模型和优化策略进行研究。法学硕士越来越多地用于放射学报告的质量保证,但他们的语言能力是否转化为临床重大错误的检测仍不清楚。错误检测具有类型依赖性,GPT-4.1和Llama 3.3 70B在生理和解剖错误方面表现较差,但在不适当的建议方面表现较好。临床相关性法学硕士未能发现放射学报告中的大多数临床后果错误,特别是训练有素的放射科医生可以迅速识别的生理上不可能的陈述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Radiology
European Radiology 医学-核医学
CiteScore
11.60
自引率
8.50%
发文量
874
审稿时长
2-4 weeks
期刊介绍: European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field. This is the Journal of the European Society of Radiology, and the official journal of a number of societies. From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书