Clinical Application of the Modified Scleral Tunnel Intraocular Lens Ciliary Sulcus Suture-Fixation Technique.

IF 2.2 4区 医学 Q3 OPHTHALMOLOGY
Journal of Ophthalmology Pub Date : 2026-06-15 eCollection Date: 2026-01-01 DOI:10.1155/joph/5043535
Bingzhen Li, Yiyun Liu, Xuran Long, Hong Qi
{"title":"Clinical Application of the Modified Scleral Tunnel Intraocular Lens Ciliary Sulcus Suture-Fixation Technique.","authors":"Bingzhen Li, Yiyun Liu, Xuran Long, Hong Qi","doi":"10.1155/joph/5043535","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the visual outcomes, intraocular lens (IOL) positional stability, and impact on the ocular surface following a novel modified scleral tunnel IOL ciliary sulcus suture-fixation technique in eyes without adequate capsular support.</p><p><strong>Design: </strong>A prospective single-arm cohort study.</p><p><strong>Methods: </strong>A total of 48 eyes underwent the modified fixation procedure, which utilized a microcurved needle with 10-0 polypropylene suture to create a scleral tunnel for suture burial. Main outcome measures were assessed preoperatively and at 1 and 3 months postoperatively. Visual function was evaluated by measuring uncorrected distance visual acuity (UDVA) and best-corrected distance visual acuity (BCVA) using standard logarithmic charts and by manifest refraction. IOL position (decentration and tilt) was quantified using anterior segment optical coherence tomography (AS-OCT) with ImageJ software analysis. Ocular surface impact was assessed via tear film break-up time (BUT), corneal fluorescein staining (FL), and the Schirmer I test (SIT).</p><p><strong>Results: </strong>Visual outcomes significantly improved: postoperative UDVA was 0.41 ± 0.36 logMAR, and BCVA was 0.25 ± 0.32 logMAR, compared to preoperative 1.16 ± 0.65 and 0.61 ± 0.60 logMAR, respectively (both <i>p</i> < 0.001). IOL position was stable, with a mean horizontal and vertical decentration of 0.38 mm and 0.39 mm, respectively, and a mean tilt of 3.34° and 3.42°. Ocular surface parameters showed a transient disturbance at 1 month (BUT decreased, FL increased) but returned to near-baseline levels by 3 months postoperatively.</p><p><strong>Conclusion: </strong>The modified scleral tunnel IOL fixation technique effectively restores visual function, provides excellent and stable IOL positioning, and induces only transient, reversible disturbance to the ocular surface. This method represents a safe and effective surgical option for eyes lacking capsular support.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":"2026 ","pages":"5043535"},"PeriodicalIF":2.2000,"publicationDate":"2026-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13269833/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/joph/5043535","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the visual outcomes, intraocular lens (IOL) positional stability, and impact on the ocular surface following a novel modified scleral tunnel IOL ciliary sulcus suture-fixation technique in eyes without adequate capsular support.

Design: A prospective single-arm cohort study.

Methods: A total of 48 eyes underwent the modified fixation procedure, which utilized a microcurved needle with 10-0 polypropylene suture to create a scleral tunnel for suture burial. Main outcome measures were assessed preoperatively and at 1 and 3 months postoperatively. Visual function was evaluated by measuring uncorrected distance visual acuity (UDVA) and best-corrected distance visual acuity (BCVA) using standard logarithmic charts and by manifest refraction. IOL position (decentration and tilt) was quantified using anterior segment optical coherence tomography (AS-OCT) with ImageJ software analysis. Ocular surface impact was assessed via tear film break-up time (BUT), corneal fluorescein staining (FL), and the Schirmer I test (SIT).

Results: Visual outcomes significantly improved: postoperative UDVA was 0.41 ± 0.36 logMAR, and BCVA was 0.25 ± 0.32 logMAR, compared to preoperative 1.16 ± 0.65 and 0.61 ± 0.60 logMAR, respectively (both p < 0.001). IOL position was stable, with a mean horizontal and vertical decentration of 0.38 mm and 0.39 mm, respectively, and a mean tilt of 3.34° and 3.42°. Ocular surface parameters showed a transient disturbance at 1 month (BUT decreased, FL increased) but returned to near-baseline levels by 3 months postoperatively.

Conclusion: The modified scleral tunnel IOL fixation technique effectively restores visual function, provides excellent and stable IOL positioning, and induces only transient, reversible disturbance to the ocular surface. This method represents a safe and effective surgical option for eyes lacking capsular support.

改良巩膜隧道人工晶状体睫状沟缝合固定技术的临床应用。
目的:评价改良巩膜隧道人工晶状体睫状沟缝合固定技术在无晶状体支持的情况下的视力结果、人工晶状体位置稳定性及对眼表的影响。设计:前瞻性单臂队列研究。方法:采用10-0聚丙烯缝线的微弯针形成巩膜隧道进行缝合埋置,48只眼采用改良固定术。术前、术后1个月和3个月评估主要结局指标。采用标准对数图测量未矫正距离视力(UDVA)和最佳矫正距离视力(BCVA)及明显屈光来评价视力。采用前段光学相干断层扫描(AS-OCT)和ImageJ软件分析,量化人工晶状体的位置(离体和倾斜)。通过泪膜破裂时间(BUT)、角膜荧光素染色(FL)和Schirmer I试验(SIT)评估眼表冲击。结果:视力明显改善,术后UDVA为0.41±0.36 logMAR, BCVA为0.25±0.32 logMAR,术前UDVA为1.16±0.65,BCVA为0.61±0.60 logMAR(均p)。结论:改良巩膜隧道人工晶状体固定技术可有效恢复视功能,提供良好稳定的人工晶状体定位,仅对眼表造成短暂、可逆的干扰。这种方法是一种安全有效的手术选择,为眼睛缺乏包膜支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书