{"title":"Proof-of-principle of Distributed Acoustic Sensing (DAS) for detection of sewer defects, extraneous water intrusion and sewage exfiltration.","authors":"Hao Zhang, Hao Wu, Haifeng Jia, Chuandong Jiang, Huub Rijnaarts, Wei-Shan Chen, Adriaan Mels","doi":"10.2166/wst.2026.291","DOIUrl":null,"url":null,"abstract":"<p><p>Extraneous water intrusion and sewage exfiltration due to sewer defects are difficult to detect. This study presents a potentially effective sewer defect diagnosis method, namely, the distributed acoustic sensing (DAS) framework. Firstly, a proof-of-principle study was performed using a 5-m sewer model for DAS signal analysis. Controlled intrusions were applied with defined flow rate and fall height, under defined static and dynamic background flows. Under laboratory conditions, pouring-induced intrusion events generated localized transient strain impacts with clear time- and frequency-domain fingerprints, enabling DAS to localize the impact region and distinguish between inflow-side and manhole-side responses. For exfiltration, time-domain responses of the DAS signals were too weak, but upon amplification of the power spectral density (PSD) between 20 and 30 Hz, leakages were detected by consistent and localized amplified signals under experimental scenarios. Secondly, a field test was conducted on an 800-m sanitary sewer in operation. Despite urban noise interference, statistical screening of amplified PSD signals between 20 and 30 Hz identified recurrent mid-level events to be associated with two candidate defective segments, which were later confirmed. These results provide an initial proof-of-principle field demonstration, but the field evidence remains limited and further validation is still required before broader engineering applicability.</p>","PeriodicalId":23653,"journal":{"name":"Water Science and Technology","volume":"93 11","pages":"1674-1690"},"PeriodicalIF":2.8000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Science and Technology","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wst.2026.291","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Extraneous water intrusion and sewage exfiltration due to sewer defects are difficult to detect. This study presents a potentially effective sewer defect diagnosis method, namely, the distributed acoustic sensing (DAS) framework. Firstly, a proof-of-principle study was performed using a 5-m sewer model for DAS signal analysis. Controlled intrusions were applied with defined flow rate and fall height, under defined static and dynamic background flows. Under laboratory conditions, pouring-induced intrusion events generated localized transient strain impacts with clear time- and frequency-domain fingerprints, enabling DAS to localize the impact region and distinguish between inflow-side and manhole-side responses. For exfiltration, time-domain responses of the DAS signals were too weak, but upon amplification of the power spectral density (PSD) between 20 and 30 Hz, leakages were detected by consistent and localized amplified signals under experimental scenarios. Secondly, a field test was conducted on an 800-m sanitary sewer in operation. Despite urban noise interference, statistical screening of amplified PSD signals between 20 and 30 Hz identified recurrent mid-level events to be associated with two candidate defective segments, which were later confirmed. These results provide an initial proof-of-principle field demonstration, but the field evidence remains limited and further validation is still required before broader engineering applicability.

分布式声学传感(DAS)用于检测下水道缺陷,外来水入侵和污水泄漏的原理证明。
由于下水道缺陷造成的外来水侵入和污水外溢难以检测。本研究提出了一种潜在有效的下水道缺陷诊断方法,即分布式声传感(DAS)框架。首先,使用5米下水道模型进行DAS信号分析的原理验证研究。在确定的静态和动态背景流下,采用确定的流速和落差高度进行控制入侵。在实验室条件下,浇注引起的侵入事件产生了局部瞬态应变冲击,具有清晰的时域和频域指纹,使DAS能够定位冲击区域,并区分流入侧和井口侧的响应。对于泄漏,DAS信号的时域响应太弱,但在20 ~ 30 Hz的功率谱密度(PSD)放大后,在实验场景下,通过一致的局部放大信号检测到泄漏。其次,对一条运行中的800米卫生污水管道进行了现场试验。尽管存在城市噪声干扰,但对20至30 Hz之间放大的PSD信号进行统计筛选,确定了与两个候选缺陷片段相关的反复出现的中等水平事件,这一点后来得到了证实。这些结果提供了初步的原理验证现场演示,但现场证据仍然有限,在更广泛的工程应用之前,还需要进一步验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Water Science and Technology
Water Science and Technology 环境科学-工程:环境
CiteScore
4.90
自引率
3.70%
发文量
366
审稿时长
4.4 months
期刊介绍: Water Science and Technology publishes peer-reviewed papers on all aspects of the science and technology of water and wastewater. Papers are selected by a rigorous peer review procedure with the aim of rapid and wide dissemination of research results, development and application of new techniques, and related managerial and policy issues. Scientists, engineers, consultants, managers and policy-makers will find this journal essential as a permanent record of progress of research activities and their practical applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书