Huan Wei, Tomáš Riedel, Zuzana Riedelová, Melanie Wolf, Christian Schlensak, Meltem Avci-Adali
{"title":"Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters","authors":"Huan Wei, Tomáš Riedel, Zuzana Riedelová, Melanie Wolf, Christian Schlensak, Meltem Avci-Adali","doi":"10.1007/s10856-026-07087-2","DOIUrl":null,"url":null,"abstract":"<div><p>Flow diverters play an important role in the endovascular treatment of intracranial aneurysms; however, their use can be associated with thromboembolic complications. Thus, in recent years, flow diverters with surface coatings have been developed to prevent thrombus-related complications. In this study, the hemocompatibility of the flow diverters FRED X with poly(2-methoxyethyl acrylate) (PMEA) coating and the DERIVO 2heal with fibrin/heparin coating, as well as the uncoated DERIVO 2 flow diverter, was evaluated using an in vitro blood circulation model. Using enzyme-linked immunosorbent assay (ELISA), biomarkers of thrombocytes (β-thromboglobulin (β-TG)), coagulation (thrombin-antithrombin complex (TAT)), complement system (SC5b-9), and inflammation (PMN elastase) activation were analyzed. Further analyses comprised thrombogenicity assessment by scanning electron microscopy and measurement of blood cell counts and hemolysis. The uncoated DERIVO 2 flow diverter exhibited increased coagulation and platelet activation, accompanied by enhanced adhesion of platelets to the blood-contacting surfaces. In contrast, both the FRED X and the DERIVO 2-heal flow diverter could effectively reduce the coagulation (TAT) and platelet activation (β-TG) and prevent the adhesion of platelets. Notably, DERIVO 2heal flow diverter induced significantly lower activation of the complement system (SC5b-9) and reduced inflammatory response (PMN elastase) compared to FRED X flow diverter. These findings indicate the improved hemocompatibility of the fibrin/heparin-coated DERIVO 2heal flow diverter and its potential to reduce thromboinflammatory complications.</p><h3>Graphical Abstract</h3><div><figure><div><div><picture><source><img></source></picture><span>The alternative text for this image may have been generated using AI.</span></div></div></figure></div></div>","PeriodicalId":647,"journal":{"name":"Journal of Materials Science: Materials in Medicine","volume":"37 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2026-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10856-026-07087-2.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Science: Materials in Medicine","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10856-026-07087-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Flow diverters play an important role in the endovascular treatment of intracranial aneurysms; however, their use can be associated with thromboembolic complications. Thus, in recent years, flow diverters with surface coatings have been developed to prevent thrombus-related complications. In this study, the hemocompatibility of the flow diverters FRED X with poly(2-methoxyethyl acrylate) (PMEA) coating and the DERIVO 2heal with fibrin/heparin coating, as well as the uncoated DERIVO 2 flow diverter, was evaluated using an in vitro blood circulation model. Using enzyme-linked immunosorbent assay (ELISA), biomarkers of thrombocytes (β-thromboglobulin (β-TG)), coagulation (thrombin-antithrombin complex (TAT)), complement system (SC5b-9), and inflammation (PMN elastase) activation were analyzed. Further analyses comprised thrombogenicity assessment by scanning electron microscopy and measurement of blood cell counts and hemolysis. The uncoated DERIVO 2 flow diverter exhibited increased coagulation and platelet activation, accompanied by enhanced adhesion of platelets to the blood-contacting surfaces. In contrast, both the FRED X and the DERIVO 2-heal flow diverter could effectively reduce the coagulation (TAT) and platelet activation (β-TG) and prevent the adhesion of platelets. Notably, DERIVO 2heal flow diverter induced significantly lower activation of the complement system (SC5b-9) and reduced inflammatory response (PMN elastase) compared to FRED X flow diverter. These findings indicate the improved hemocompatibility of the fibrin/heparin-coated DERIVO 2heal flow diverter and its potential to reduce thromboinflammatory complications.
Graphical Abstract
The alternative text for this image may have been generated using AI.
期刊介绍:
The Journal of Materials Science: Materials in Medicine publishes refereed papers providing significant progress in the application of biomaterials and tissue engineering constructs as medical or dental implants, prostheses and devices. Coverage spans a wide range of topics from basic science to clinical applications, around the theme of materials in medicine and dentistry. The central element is the development of synthetic and natural materials used in orthopaedic, maxillofacial, cardiovascular, neurological, ophthalmic and dental applications. Special biomedical topics include biomaterial synthesis and characterisation, biocompatibility studies, nanomedicine, tissue engineering constructs and cell substrates, regenerative medicine, computer modelling and other advanced experimental methodologies.