Multispline catheter mapping of the coronary ostia to guide aortic root ablation.

IF 4.9 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Alejandro Carta-Bergaz, Roberto Gómez-Sánchez, Esteban González-Torrecilla, Pablo Ávila, Felipe Atienza, Ana González-Mansilla, Elena Rodríguez-González, Ángel Arenal
{"title":"Multispline catheter mapping of the coronary ostia to guide aortic root ablation.","authors":"Alejandro Carta-Bergaz, Roberto Gómez-Sánchez, Esteban González-Torrecilla, Pablo Ávila, Felipe Atienza, Ana González-Mansilla, Elena Rodríguez-González, Ángel Arenal","doi":"10.1016/j.rec.2026.05.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and objectives: </strong>Safe ablation of ventricular arrhythmias from the left ventricular outflow tract (LVOT) requires accurate coronary ostia localization, but conventional imaging adds procedural complexity, radiation, and cost. The aim of this study was to determine whether electroanatomic coronary ostial localization using multispline-based catheters reproduces computed tomography (CT)-defined ostial anatomy and could serve as an anatomic reference.</p><p><strong>Methods: </strong>Among 85 consecutive patients undergoing evaluation for LVOT ablation, 51 met the inclusion criteria and were prospectively enrolled in a 2-phase observational study: a CT-validated cohort (n=26) followed by a non-CT implementation cohort (n=25). Coronary ostia were identified electroanatomically using predefined protrusion criteria and compared with CT in a validation cohort. An exploratory electrocardiogram-based model was tested to predict ostial proximity.</p><p><strong>Results: </strong>Electroanatomic identification of the left coronary artery (LCA) ostium was achieved in all patients (100%; 95%CI, 93.0%-100%), and of the right coronary artery (RCA) in 73% (95% CI, 58.3%-84.1%). In the CT-validation cohort, electroanatomic and CT-derived ostial locations demonstrated excellent 3-dimensional concordance (LCA: 1.30±0.37 mm; RCA: 1.48±0.43 mm). In the subsequent implementation cohort, electroanatomic coronary localization was performed without systematic CT use. No ischemic clinical events occurred during 404 days of follow-up; CT in the validation cohort showed no coronary lesions. The exploratory electrocardiogram-based model suggested artery-specific variables for predicting coronary proximity.</p><p><strong>Conclusions: </strong>Electroanatomic mapping with spline-based catheters enables accurate coronary ostia localization during LVOT ablation, consistently for the LCA and in most cases for the RCA. These findings support its use as a feasible anatomical reference to inform procedural decision-making.</p>","PeriodicalId":38430,"journal":{"name":"Revista española de cardiología (English ed.)","volume":" ","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2026-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista española de cardiología (English ed.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.rec.2026.05.006","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives: Safe ablation of ventricular arrhythmias from the left ventricular outflow tract (LVOT) requires accurate coronary ostia localization, but conventional imaging adds procedural complexity, radiation, and cost. The aim of this study was to determine whether electroanatomic coronary ostial localization using multispline-based catheters reproduces computed tomography (CT)-defined ostial anatomy and could serve as an anatomic reference.

Methods: Among 85 consecutive patients undergoing evaluation for LVOT ablation, 51 met the inclusion criteria and were prospectively enrolled in a 2-phase observational study: a CT-validated cohort (n=26) followed by a non-CT implementation cohort (n=25). Coronary ostia were identified electroanatomically using predefined protrusion criteria and compared with CT in a validation cohort. An exploratory electrocardiogram-based model was tested to predict ostial proximity.

Results: Electroanatomic identification of the left coronary artery (LCA) ostium was achieved in all patients (100%; 95%CI, 93.0%-100%), and of the right coronary artery (RCA) in 73% (95% CI, 58.3%-84.1%). In the CT-validation cohort, electroanatomic and CT-derived ostial locations demonstrated excellent 3-dimensional concordance (LCA: 1.30±0.37 mm; RCA: 1.48±0.43 mm). In the subsequent implementation cohort, electroanatomic coronary localization was performed without systematic CT use. No ischemic clinical events occurred during 404 days of follow-up; CT in the validation cohort showed no coronary lesions. The exploratory electrocardiogram-based model suggested artery-specific variables for predicting coronary proximity.

Conclusions: Electroanatomic mapping with spline-based catheters enables accurate coronary ostia localization during LVOT ablation, consistently for the LCA and in most cases for the RCA. These findings support its use as a feasible anatomical reference to inform procedural decision-making.

冠状动脉开口多样条导管定位指导主动脉根部消融。
前言和目的:从左心室流出道(LVOT)进行室性心律失常的安全消融需要精确的冠状动脉口定位,但常规成像增加了程序的复杂性、辐射和成本。本研究的目的是确定使用基于多样条导管的冠状动脉口电解剖定位是否再现计算机断层扫描(CT)定义的口解剖,并可作为解剖学参考。方法:在85例连续接受LVOT消融评估的患者中,51例符合纳入标准,并前瞻性地纳入了一项两期观察性研究:ct验证队列(n = 26)和非ct实施队列(n = 25)。采用预先确定的冠状动脉口突出标准进行电解剖鉴定,并在验证队列中与CT进行比较。我们测试了一种探索性的基于心电图的模型来预测口腔接近度。结果:所有患者均实现了左冠状动脉(LCA)口的电解剖识别(100%;95%CI, 93.0% ~ 100%), 73%的患者实现了右冠状动脉(RCA)口的电解剖识别(95% CI, 58.3% ~ 84.1%)。在ct验证队列中,电解剖和ct导出的口腔位置显示出良好的三维一致性(LCA: 1.30±0.37 mm; RCA: 1.48±0.43 mm)。在随后的实施队列中,在没有系统CT使用的情况下进行了电子解剖冠状动脉定位。随访404 d无缺血性临床事件发生;验证队列的CT未见冠状动脉病变。探索性心电图为基础的模型提出了预测冠状动脉接近的动脉特异性变量。结论:在LVOT消融过程中,以样条为基础的导管的电解剖定位能够精确地定位冠状动脉口,对于LCA和大多数情况下的RCA是一致的。这些发现支持其作为可行的解剖学参考,以告知程序性决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
0.00%
发文量
219
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书