{"title":"Real-Time Shear Wave Elastography Combined With MRI-Ultrasound Cognitive Fusion Targeted Biopsy for Repeat Prostate Biopsy.","authors":"Zhouliang Zhang, Zhongkang Lai, Zhijian Zhu, Chang Li, Huiping Chen, Jianfeng Li","doi":"10.56434/j.arch.esp.urol.20267904.81","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>This study aimed to evaluate the diagnostic value of real-time shear wave elastography (SWE) combined with magnetic resonance imaging-ultrasound (MRI-US) cognitive fusion targeted biopsy in repeat prostate biopsy.</p><p><strong>Methods: </strong>The retrospective cohort study comprised 120 patients who underwent transperineal repeat biopsy. Group A (n = 64) had standard cognitive fusion targeted biopsy plus systematic biopsy; Group B (n = 56) had additional real-time SWE before cognitive fusion to refine targeting. The primary endpoint of the study was the clinically significant prostate cancer (csPCa), which was based on targeted cores. Secondary endpoints encompassed the following: overall PCa detection, core-specific cancer detection rate, agreement with final pathology, diagnostic performance, and complications.</p><p><strong>Results: </strong>It is evident from the data that Group B had a significantly higher csPCa detection rate in comparison to Group A (<i>p</i> < 0.05). The number of biopsy cores was comparable, yet the core-specific cancer detection rate was higher in Group B (<i>p</i> < 0.05). In Group B, maximum elastic modulus of shear wave elastography (SWE-Emax) values and the proportion of the Prostate Imaging Reporting and Data System (PI-RADS) 5 lesions were significantly higher in csPCa lesions than in benign lesions (<i>p</i> < 0.001). Group B had superior sensitivity, specificity, accuracy, and agreement with final pathology. Receiver operating characteristic (ROC) curve analysis suggested that the combination of SWE-Emax with PI-RADS score yielded a higher diagnostic performance than either individual method (area under the curve (AUC) = 0.904, 95%confidence interval (CI): 0.825-0.983, <i>p</i> < 0.001). Subsequent analysis revealed no significant disparities in complication rates between the two groups (<i>p</i> > 0.05).</p><p><strong>Conclusions: </strong>The combination of real-time SWE and MRI-US cognitive fusion targeted biopsy has been shown to be associated with a higher detection rate of clinically significant prostate cancer and improved biopsy accuracy during repeat biopsies, offering incremental diagnostic value without additional risks.</p>","PeriodicalId":48852,"journal":{"name":"Archivos Espanoles De Urologia","volume":"79 4","pages":"692-699"},"PeriodicalIF":1.2000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos Espanoles De Urologia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.56434/j.arch.esp.urol.20267904.81","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: This study aimed to evaluate the diagnostic value of real-time shear wave elastography (SWE) combined with magnetic resonance imaging-ultrasound (MRI-US) cognitive fusion targeted biopsy in repeat prostate biopsy.

Methods: The retrospective cohort study comprised 120 patients who underwent transperineal repeat biopsy. Group A (n = 64) had standard cognitive fusion targeted biopsy plus systematic biopsy; Group B (n = 56) had additional real-time SWE before cognitive fusion to refine targeting. The primary endpoint of the study was the clinically significant prostate cancer (csPCa), which was based on targeted cores. Secondary endpoints encompassed the following: overall PCa detection, core-specific cancer detection rate, agreement with final pathology, diagnostic performance, and complications.

Results: It is evident from the data that Group B had a significantly higher csPCa detection rate in comparison to Group A (p < 0.05). The number of biopsy cores was comparable, yet the core-specific cancer detection rate was higher in Group B (p < 0.05). In Group B, maximum elastic modulus of shear wave elastography (SWE-Emax) values and the proportion of the Prostate Imaging Reporting and Data System (PI-RADS) 5 lesions were significantly higher in csPCa lesions than in benign lesions (p < 0.001). Group B had superior sensitivity, specificity, accuracy, and agreement with final pathology. Receiver operating characteristic (ROC) curve analysis suggested that the combination of SWE-Emax with PI-RADS score yielded a higher diagnostic performance than either individual method (area under the curve (AUC) = 0.904, 95%confidence interval (CI): 0.825-0.983, p < 0.001). Subsequent analysis revealed no significant disparities in complication rates between the two groups (p > 0.05).

Conclusions: The combination of real-time SWE and MRI-US cognitive fusion targeted biopsy has been shown to be associated with a higher detection rate of clinically significant prostate cancer and improved biopsy accuracy during repeat biopsies, offering incremental diagnostic value without additional risks.

实时横波弹性成像联合mri -超声认知融合靶向活检用于前列腺重复活检。
目的:探讨实时横波弹性成像(SWE)联合磁共振成像-超声(MRI-US)认知融合靶向活检在重复前列腺活检中的诊断价值。方法:回顾性队列研究纳入120例经会阴重复活检患者。A组(n = 64)行标准认知融合靶向活检加系统活检;B组(n = 56)在认知融合前进行额外的实时SWE以完善靶向。该研究的主要终点是临床显著性前列腺癌(csPCa),这是基于靶向核心。次要终点包括:总体PCa检测,核心特异性癌症检出率,与最终病理的一致性,诊断表现和并发症。结果:B组csPCa检出率明显高于a组(p < 0.05)。B组活检芯数比较,但芯特异性肿瘤检出率高于B组(p < 0.05)。B组csPCa病变的最大剪切波弹性模量(SWE-Emax)值和前列腺成像报告与数据系统(PI-RADS) 5病变比例显著高于良性病变(p < 0.001)。B组具有更好的敏感性、特异性、准确性和与最终病理的一致性。受试者工作特征(ROC)曲线分析表明,SWE-Emax与PI-RADS评分联合使用的诊断效果优于单独使用的方法(曲线下面积(AUC) = 0.904, 95%可信区间(CI): 0.825 ~ 0.983, p < 0.001)。后续分析显示两组并发症发生率无显著差异(p < 0.05)。结论:实时SWE联合MRI-US认知融合靶向活检已被证明可提高临床显著性前列腺癌的检出率,并可提高重复活检时的活检准确性,在无额外风险的情况下提供增量诊断价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Archivos Espanoles De Urologia
Archivos Espanoles De Urologia UROLOGY & NEPHROLOGY-
CiteScore
0.90
自引率
0.00%
发文量
111
期刊介绍: Archivos Españoles de Urología published since 1944, is an international peer review, susbscription Journal on Urology with original and review articles on different subjets in Urology: oncology, endourology, laparoscopic, andrology, lithiasis, pediatrics , urodynamics,... Case Report are also admitted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书