Anterior Chambers Shallower Than 2.5 mm in Eyes With Short to Normal Axial Length: Can Artificial Intelligence-Based Lens Formulas Achieve Reliable Accuracy?
{"title":"Anterior Chambers Shallower Than 2.5 mm in Eyes With Short to Normal Axial Length: Can Artificial Intelligence-Based Lens Formulas Achieve Reliable Accuracy?","authors":"Chuang Li, Yinwei Song, Ting Meng, Wei Peng","doi":"10.3928/1081597X-20260414-01","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the performance of artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in eyes with extremely shallow anterior chambers (anterior chamber depth [ACD] < 2.5 mm).</p><p><strong>Methods: </strong>This retrospective study enrolled 120 eyes of 120 patients with ACD < 2.5 mm who underwent phacoemulsification and IOL implantation. Seven AI formulas were evaluated: Hill-RBF 3.0, Kane, PEARL-DGS, LSF Al, Hoffer QST, Karmona, and Nallasamy. Subgroup analysis was performed based on lens thickness (LT).</p><p><strong>Results: </strong>The Kane, PEARL-DGS, and Hoffer QST formulas exhibited no significant systematic bias (all <i>P</i> > .05) and demonstrated comparable refractive predictability in the overall cohort. In the thin lens subgroup (LT < 4 mm), the PEARL-DGS, LSF Al, and Hoffer QST yielded superior precision. In the intermediate subgroup (4 mm ⩽ LT < 5 mm), the Hill-RBF 3.0, Kane, and PEARL-DGS achieved higher accuracy. Notably, in eyes with pronounced lens-related crowding (LT ⩾ 5 mm), the Hill-RBF 3.0, Kane, and Hoffer QST remained the most reliable.</p><p><strong>Conclusions: </strong>Lens thickness is a critical determinant of refractive outcomes in eyes with extremely shallow ACD. Given that no individual AI-based formula maintains optimal predictive performance across the entire spectrum of lens morphology, a stratified formula selection strategy is recommended. Specifically, the PEARL-DGS is prioritized for thin lenses, Kane for intermediate profiles, and Hoffer QST for eyes with pronounced lens disproportion.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"42 6","pages":"e586-e593"},"PeriodicalIF":2.9000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20260414-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the performance of artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in eyes with extremely shallow anterior chambers (anterior chamber depth [ACD] < 2.5 mm).
Methods: This retrospective study enrolled 120 eyes of 120 patients with ACD < 2.5 mm who underwent phacoemulsification and IOL implantation. Seven AI formulas were evaluated: Hill-RBF 3.0, Kane, PEARL-DGS, LSF Al, Hoffer QST, Karmona, and Nallasamy. Subgroup analysis was performed based on lens thickness (LT).
Results: The Kane, PEARL-DGS, and Hoffer QST formulas exhibited no significant systematic bias (all P > .05) and demonstrated comparable refractive predictability in the overall cohort. In the thin lens subgroup (LT < 4 mm), the PEARL-DGS, LSF Al, and Hoffer QST yielded superior precision. In the intermediate subgroup (4 mm ⩽ LT < 5 mm), the Hill-RBF 3.0, Kane, and PEARL-DGS achieved higher accuracy. Notably, in eyes with pronounced lens-related crowding (LT ⩾ 5 mm), the Hill-RBF 3.0, Kane, and Hoffer QST remained the most reliable.
Conclusions: Lens thickness is a critical determinant of refractive outcomes in eyes with extremely shallow ACD. Given that no individual AI-based formula maintains optimal predictive performance across the entire spectrum of lens morphology, a stratified formula selection strategy is recommended. Specifically, the PEARL-DGS is prioritized for thin lenses, Kane for intermediate profiles, and Hoffer QST for eyes with pronounced lens disproportion.
期刊介绍:
The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as:
• Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics”
• Supplemental videos and materials available for many articles
• Access to current articles, as well as several years of archived content
• Articles posted online just 2 months after acceptance.