{"title":"Less is more: how reducing the ablation atmosphere pressure can boost sensitivity for fluorine in laser-induced breakdown spectroscopy","authors":"David Ken Gibbs and Andreas Limbeck","doi":"10.1039/D6JA00144K","DOIUrl":null,"url":null,"abstract":"<p >Laser-induced breakdown spectroscopy (LIBS) is a rapid and minimally destructive technique which enables measurement of almost every element of the periodic table. However, fluorine determination remains challenging due to low sensitivity and weak emission signals. In this work, the influence of reduced ablation atmosphere pressure on fluorine detection by LIBS is systematically investigated, including parameter optimization steps for gate delay and laser energy. A significant increase in fluorine signal intensity was observed with decreasing pressure. The impact of pressure on signal stability, calibration behaviour, and limits of detection was assessed and compared to measurements at atmospheric pressure. In that regard, different evaluation approaches, including univariate and multivariate models (using Partial Least Squares) were considered. The results demonstrate that reduced-pressure conditions lead to improved sensitivity and lower limits of detection, enabling more reliable fluorine quantification. For the univariate calibration models, sensitivity was approx. double at 50 mbar compared to atmospheric pressure, while the limit of detection reduced from 505 to 104 µg g<small><sup>−1</sup></small>. Further, sensitivity in the multivariate models improved by up to 80% leading to a decreased limit of detection of 121 µg g<small><sup>−1</sup></small> at 50 mbar in comparison to 286 µg g<small><sup>−1</sup></small> at atmospheric pressure. The findings presented here show that controlling the ambient pressure is an effective strategy to enhance fluorine detection by LIBS without requiring extensive sample preparation or major instrumental modifications. This approach broadens the applicability of LIBS for the direct analysis of fluorine in solid samples and provides a practical route to improved analytical performance.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 6","pages":" 2081-2096"},"PeriodicalIF":3.3000,"publicationDate":"2026-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d6ja00144k?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d6ja00144k","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Laser-induced breakdown spectroscopy (LIBS) is a rapid and minimally destructive technique which enables measurement of almost every element of the periodic table. However, fluorine determination remains challenging due to low sensitivity and weak emission signals. In this work, the influence of reduced ablation atmosphere pressure on fluorine detection by LIBS is systematically investigated, including parameter optimization steps for gate delay and laser energy. A significant increase in fluorine signal intensity was observed with decreasing pressure. The impact of pressure on signal stability, calibration behaviour, and limits of detection was assessed and compared to measurements at atmospheric pressure. In that regard, different evaluation approaches, including univariate and multivariate models (using Partial Least Squares) were considered. The results demonstrate that reduced-pressure conditions lead to improved sensitivity and lower limits of detection, enabling more reliable fluorine quantification. For the univariate calibration models, sensitivity was approx. double at 50 mbar compared to atmospheric pressure, while the limit of detection reduced from 505 to 104 µg g−1. Further, sensitivity in the multivariate models improved by up to 80% leading to a decreased limit of detection of 121 µg g−1 at 50 mbar in comparison to 286 µg g−1 at atmospheric pressure. The findings presented here show that controlling the ambient pressure is an effective strategy to enhance fluorine detection by LIBS without requiring extensive sample preparation or major instrumental modifications. This approach broadens the applicability of LIBS for the direct analysis of fluorine in solid samples and provides a practical route to improved analytical performance.
激光诱导击穿光谱(LIBS)是一种快速且破坏性最小的技术,可以测量元素周期表中的几乎所有元素。然而,由于灵敏度低和发射信号弱,氟的测定仍然具有挑战性。本文系统研究了降低烧蚀大气压对LIBS检测氟的影响,包括栅极延迟和激光能量的参数优化步骤。随着压力的降低,氟信号强度显著增加。评估了压力对信号稳定性、校准行为和检测极限的影响,并将其与大气压下的测量结果进行了比较。在这方面,考虑了不同的评估方法,包括单变量和多变量模型(使用偏最小二乘法)。结果表明,减压条件提高了灵敏度,降低了检测限,使氟定量更加可靠。对于单变量校准模型,灵敏度近似。与大气压相比,在50mbar下加倍,而检测限从505降至104µg g−1。此外,多变量模型的灵敏度提高了80%,导致在50毫巴下的检测限为121 μ g g−1,而在大气压下为286 μ g g−1。本文的研究结果表明,控制环境压力是提高LIBS检测氟的有效策略,而不需要大量的样品制备或重大的仪器修改。该方法拓宽了LIBS直接分析固体样品中氟的适用性,并为提高分析性能提供了一条实用途径。