Corrosion-Driven Degradation of Mg WE43 Plates for Mandibular Fracture Fixation: An In-Silico Study

IF 3 4区 医学 Q2 ENGINEERING, BIOMEDICAL
Reza Izadi, Mohadese Rajaeirad, Sandipan Roy
{"title":"Corrosion-Driven Degradation of Mg WE43 Plates for Mandibular Fracture Fixation: An In-Silico Study","authors":"Reza Izadi,&nbsp;Mohadese Rajaeirad,&nbsp;Sandipan Roy","doi":"10.1002/jbm.b.70112","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Biodegradable Mg WE43 alloys offer bone-matched stiffness and osteogenic degradation products for mandibular fracture fixation but undergo unpredictable uniform and pitting corrosion that may compromise early stability. Integrating corrosion kinetics into finite element analysis (FEA) could inform implant design and degradation scheduling. To evaluate mechanical stability and degradation of a Mg WE43 mini-plate for mandibular fractures via finite element analysis (FEA), incorporating uniform corrosion and Weibull-distributed pitting corrosion to model stochastic defect formation and growth. A subject-specific mandibular model with a 1 mm angle fracture gap was reconstructed from CT images and combined with detailed SolidWorks designs of a 1 mm-thick WE43 mini-plate and screws. The assembly was discretized with linear tetrahedral elements in ABAQUS/Explicit. A custom VUMAT subroutine implemented continuum damage mechanics–based uniform corrosion and Weibull-distributed pitting corrosion. Boundary conditions fixed the temporal region and applied 150–600 N anterior loads. Validation against experimental mass loss and stress–strain data assessed model accuracy. Over 24 days, simulated corrosion decreased plate stiffness by &gt; 60%, aligning with typical cortical bridging at ~35% residual stiffness. Ultimate tensile strength dropped from 279 to 123 MPa (56% loss) and strain at failure halved. von Mises stress redistribution shifted peak stresses toward corroded fillets, increasing by &gt; 40% under 600 N by day 24. Simulated mass-loss trajectories and stress–strain curves closely matched published experimental benchmarks. The CDM-based FEA framework reliably predicts the time-dependent mechanical degradation of WE43 Mg fixation plates, allowing for the synchronization of implant weakening with bone healing. This predictive tool enables researchers and manufacturers to enhance the implant geometry and corrosion profiles for better safety and effectiveness of biodegradable maxillofacial fixation devices.</p>\n </div>","PeriodicalId":15269,"journal":{"name":"Journal of biomedical materials research. Part B, Applied biomaterials","volume":"114 6","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical materials research. Part B, Applied biomaterials","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jbm.b.70112","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Biodegradable Mg WE43 alloys offer bone-matched stiffness and osteogenic degradation products for mandibular fracture fixation but undergo unpredictable uniform and pitting corrosion that may compromise early stability. Integrating corrosion kinetics into finite element analysis (FEA) could inform implant design and degradation scheduling. To evaluate mechanical stability and degradation of a Mg WE43 mini-plate for mandibular fractures via finite element analysis (FEA), incorporating uniform corrosion and Weibull-distributed pitting corrosion to model stochastic defect formation and growth. A subject-specific mandibular model with a 1 mm angle fracture gap was reconstructed from CT images and combined with detailed SolidWorks designs of a 1 mm-thick WE43 mini-plate and screws. The assembly was discretized with linear tetrahedral elements in ABAQUS/Explicit. A custom VUMAT subroutine implemented continuum damage mechanics–based uniform corrosion and Weibull-distributed pitting corrosion. Boundary conditions fixed the temporal region and applied 150–600 N anterior loads. Validation against experimental mass loss and stress–strain data assessed model accuracy. Over 24 days, simulated corrosion decreased plate stiffness by > 60%, aligning with typical cortical bridging at ~35% residual stiffness. Ultimate tensile strength dropped from 279 to 123 MPa (56% loss) and strain at failure halved. von Mises stress redistribution shifted peak stresses toward corroded fillets, increasing by > 40% under 600 N by day 24. Simulated mass-loss trajectories and stress–strain curves closely matched published experimental benchmarks. The CDM-based FEA framework reliably predicts the time-dependent mechanical degradation of WE43 Mg fixation plates, allowing for the synchronization of implant weakening with bone healing. This predictive tool enables researchers and manufacturers to enhance the implant geometry and corrosion profiles for better safety and effectiveness of biodegradable maxillofacial fixation devices.

用于下颌骨骨折固定的Mg - WE43钢板的腐蚀驱动降解:一项计算机研究。
可生物降解的Mg WE43合金为下颌骨折固定提供与骨匹配的刚度和成骨降解产物,但会发生不可预测的均匀和点蚀,可能会损害早期稳定性。将腐蚀动力学集成到有限元分析(FEA)中可以为植入物的设计和降解计划提供信息。通过有限元分析(FEA)评估Mg WE43下颌骨折微型钢板的力学稳定性和退化,采用均匀腐蚀和威布尔分布点蚀模型来模拟随机缺陷的形成和生长。根据CT图像重建具有1 mm角骨折间隙的受试者特定下颌模型,并结合SolidWorks对1 mm厚WE43微型钢板和螺钉的详细设计。在ABAQUS/Explicit中采用线性四面体单元对装配体进行离散。定制的VUMAT子程序实现了基于连续损伤力学的均匀腐蚀和威布尔分布点蚀。边界条件固定颞区,施加150-600 N的前负荷。根据实验质量损失和应力应变数据验证模型的准确性。在24天内,模拟腐蚀使钢板刚度降低了60%,与典型的皮质桥接的残余刚度保持在35%左右一致。极限抗拉强度从279 MPa降至123 MPa(损失56%),破坏应变减半。von Mises应力重分布将峰值应力向腐蚀圆角方向转移,在600 N条件下,到第24天峰值应力增加了40%。模拟的质量损失轨迹和应力-应变曲线与公布的实验基准非常吻合。基于cdm的有限元分析框架可靠地预测了WE43 Mg固定板随时间的机械降解,允许植入物弱化与骨愈合同步。这种预测工具使研究人员和制造商能够增强种植体的几何形状和腐蚀剖面,以提高生物可降解颌面固定装置的安全性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.50
自引率
2.90%
发文量
199
审稿时长
12 months
期刊介绍: Journal of Biomedical Materials Research – Part B: Applied Biomaterials is a highly interdisciplinary peer-reviewed journal serving the needs of biomaterials professionals who design, develop, produce and apply biomaterials and medical devices. It has the common focus of biomaterials applied to the human body and covers all disciplines where medical devices are used. Papers are published on biomaterials related to medical device development and manufacture, degradation in the body, nano- and biomimetic- biomaterials interactions, mechanics of biomaterials, implant retrieval and analysis, tissue-biomaterial surface interactions, wound healing, infection, drug delivery, standards and regulation of devices, animal and pre-clinical studies of biomaterials and medical devices, and tissue-biopolymer-material combination products. Manuscripts are published in one of six formats: • original research reports • short research and development reports • scientific reviews • current concepts articles • special reports • editorials Journal of Biomedical Materials Research – Part B: Applied Biomaterials is an official journal of the Society for Biomaterials, Japanese Society for Biomaterials, the Australasian Society for Biomaterials, and the Korean Society for Biomaterials. Manuscripts from all countries are invited but must be in English. Authors are not required to be members of the affiliated Societies, but members of these societies are encouraged to submit their work to the journal for consideration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书