PHYTO-PET - Imaging plant physiology on a long-axial field-of-view PET scanner.

IF 7.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ian Alberts, Nadine Colpo, Caroline Williams, Michael Woods, Carlos Uribe, Arman Rahmim, François Bénard
{"title":"PHYTO-PET - Imaging plant physiology on a long-axial field-of-view PET scanner.","authors":"Ian Alberts, Nadine Colpo, Caroline Williams, Michael Woods, Carlos Uribe, Arman Rahmim, François Bénard","doi":"10.1007/s00259-026-07964-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Non-human imaging using either inanimate phantoms or live animal models is sometimes performed as an alternative to human subjects but involve limitations either in fidelity for the former and ethical considerations for the latter. Plant biology has previously been probed using positron emitting tracers, but the potential for long-axial field-of-view (LAFOV) PET/CT systems with higher sensitivities and longer axial coverage in the imaging of plant biology has not yet been explored.</p><p><strong>Methods: </strong>A selection of both ornamental plants and those of agricultural interest were obtained. A method was developed for the safe instillation of radiopharmaceuticals leading to rapid transport kinetics throughout the plant. [<sup>18</sup>F]FDG was obtained from an in-house cyclotron and [<sup>68</sup>Ga]Cl<sub>3</sub> from an onsite <sup>68</sup>Ge/<sup>68</sup> Ga generator. The potential for LAFOV PET to probe transport kinetics throughout different vascular compartments was assessed, including for plant models which would not fit within the aFOV of a standard short-axial camera.</p><p><strong>Results: </strong>Several plant models were successfully imaged using both radiopharmaceuticals. Owing to differences in dispersion between [<sup>18</sup>F]FDG and [<sup>68</sup>Ga]Cl<sub>3</sub> within the phloem and xylem vascular systems, variation for the in vivo biodistribution was observed between the two radiopharmaceuticals. The transport kinetics were successfully imaged and quantified by means of dynamic imaging and the longer axial coverage lent itself to the imaging of larger plant models, such as Helianthus annuus (Sunflower).</p><p><strong>Conclusion: </strong>LAFOV PET/CT systems are feasible for both static and dynamic imaging of different plant models. In vivo biodistribution and kinetics were successfully demonstrated. The longer axial coverage enabled efficient imaging of multiple plants or plants which would not have fitted within the axial FOV of a short-axial PET/CT system.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":" ","pages":"6697-6706"},"PeriodicalIF":7.6000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-026-07964-6","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Non-human imaging using either inanimate phantoms or live animal models is sometimes performed as an alternative to human subjects but involve limitations either in fidelity for the former and ethical considerations for the latter. Plant biology has previously been probed using positron emitting tracers, but the potential for long-axial field-of-view (LAFOV) PET/CT systems with higher sensitivities and longer axial coverage in the imaging of plant biology has not yet been explored.

Methods: A selection of both ornamental plants and those of agricultural interest were obtained. A method was developed for the safe instillation of radiopharmaceuticals leading to rapid transport kinetics throughout the plant. [18F]FDG was obtained from an in-house cyclotron and [68Ga]Cl3 from an onsite 68Ge/68 Ga generator. The potential for LAFOV PET to probe transport kinetics throughout different vascular compartments was assessed, including for plant models which would not fit within the aFOV of a standard short-axial camera.

Results: Several plant models were successfully imaged using both radiopharmaceuticals. Owing to differences in dispersion between [18F]FDG and [68Ga]Cl3 within the phloem and xylem vascular systems, variation for the in vivo biodistribution was observed between the two radiopharmaceuticals. The transport kinetics were successfully imaged and quantified by means of dynamic imaging and the longer axial coverage lent itself to the imaging of larger plant models, such as Helianthus annuus (Sunflower).

Conclusion: LAFOV PET/CT systems are feasible for both static and dynamic imaging of different plant models. In vivo biodistribution and kinetics were successfully demonstrated. The longer axial coverage enabled efficient imaging of multiple plants or plants which would not have fitted within the axial FOV of a short-axial PET/CT system.

plant -PET -在长轴视场PET扫描仪上成像植物生理。
目的:使用无生命的幽灵或活体动物模型的非人类成像有时被用作人类受试者的替代方案,但前者的保真度和后者的伦理考虑都存在限制。植物生物学以前已经使用正电子发射示踪剂进行了探测,但在植物生物学成像中具有更高灵敏度和更长的轴向覆盖的长轴视场(LAFOV) PET/CT系统的潜力尚未探索。方法:选育具有观赏价值和农业价值的植物。开发了一种方法,用于放射性药物的安全注入,导致整个工厂的快速运输动力学。[18F]FDG来自内部回旋加速器,[68Ga]Cl3来自现场68Ge/ 68Ga发电机。研究人员评估了LAFOV PET在不同维管室中探测运输动力学的潜力,包括不适合标准短轴相机aFOV的植物模型。结果:使用这两种放射性药物成功地成像了几种植物模型。由于[18F]FDG和[68Ga]Cl3在韧皮部和木质部维管系统中的分散存在差异,因此观察到两种放射性药物在体内生物分布的差异。通过动态成像成功地成像和量化了运输动力学,并且较长的轴向覆盖范围使其适合于大型植物模型的成像,例如向日葵(Helianthus annuus)。结论:LAFOV PET/CT系统对不同植物模型的静态和动态成像均是可行的。成功地证明了体内生物分布和动力学。较长的轴向覆盖范围可以有效地成像多个植物或植物,而短轴向PET/CT系统的轴向视场无法适应这些植物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书