Artificial Intelligence-Enhanced Electrocardiography for the Diagnosis of Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta-Analysis.
Cian P Murray, Hugo C Temperley, Rob S Doyle, Abdullahi Khair, Patrick Devitt, Solomon Asgedom
{"title":"Artificial Intelligence-Enhanced Electrocardiography for the Diagnosis of Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta-Analysis.","authors":"Cian P Murray, Hugo C Temperley, Rob S Doyle, Abdullahi Khair, Patrick Devitt, Solomon Asgedom","doi":"10.1155/crp/4994662","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accounting for approximately 50% of heart failure, heart failure with preserved ejection fraction (HFpEF) is becoming increasingly common as populations age and multimorbidity grows. Diagnosis remains challenging, requiring multimodal testing with echocardiography, biomarkers and sometimes invasive haemodynamics. Artificial intelligence applied to the electrocardiogram (AI-ECG) offers a low-cost, scalable means of detecting HFpEF by extracting patterns beyond human interpretation.</p><p><strong>Methods: </strong>We conducted a systematic review and meta-analysis in accordance with PRISMA, registered prospectively with PROSPERO. PubMed, Embase, Web of Science, and IEEE Xplore were searched to 1 August 2025 for studies evaluating AI/ML models applied to ECGs for the diagnosis of HFpEF or left ventricular diastolic dysfunction (LVDD). Eligible studies reported diagnostic performance compared with a recognized reference standard. Risk of bias was assessed with QUADAS-AI. AUROC values were pooled using a logit transformation and random-effects model, with results back-transformed for interpretability.</p><p><strong>Results: </strong>Ten studies (2021-2025) met inclusion criteria, encompassing > 270,000 participants across diverse populations. Seven studies provided sufficient data for pooling, contributing 11 independent cohorts. The pooled AUROC was 0.84 (95% CI 0.78-0.88), indicating good discriminatory ability, though heterogeneity was extreme (I<sup>2</sup> = 100%). Three additional studies reported diagnostic metrics without AUROC variance and were synthesized narratively. Risk of bias was moderate to high in several domains, driven by selective cohorts, inconsistent reference standards, and incomplete reporting.</p><p><strong>Conclusions: </strong>AI-ECG shows promise for the detection of HFpEF, but the current evidence base is predominantly retrospective, methodologically heterogeneous, and limited by variable reference standards and insufficient external validation. No prospective, outcome-based studies have yet established its clinical utility, and real-world implementation remains untested.</p>","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"2026 ","pages":"4994662"},"PeriodicalIF":2.1000,"publicationDate":"2026-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13238258/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/crp/4994662","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Accounting for approximately 50% of heart failure, heart failure with preserved ejection fraction (HFpEF) is becoming increasingly common as populations age and multimorbidity grows. Diagnosis remains challenging, requiring multimodal testing with echocardiography, biomarkers and sometimes invasive haemodynamics. Artificial intelligence applied to the electrocardiogram (AI-ECG) offers a low-cost, scalable means of detecting HFpEF by extracting patterns beyond human interpretation.
Methods: We conducted a systematic review and meta-analysis in accordance with PRISMA, registered prospectively with PROSPERO. PubMed, Embase, Web of Science, and IEEE Xplore were searched to 1 August 2025 for studies evaluating AI/ML models applied to ECGs for the diagnosis of HFpEF or left ventricular diastolic dysfunction (LVDD). Eligible studies reported diagnostic performance compared with a recognized reference standard. Risk of bias was assessed with QUADAS-AI. AUROC values were pooled using a logit transformation and random-effects model, with results back-transformed for interpretability.
Results: Ten studies (2021-2025) met inclusion criteria, encompassing > 270,000 participants across diverse populations. Seven studies provided sufficient data for pooling, contributing 11 independent cohorts. The pooled AUROC was 0.84 (95% CI 0.78-0.88), indicating good discriminatory ability, though heterogeneity was extreme (I2 = 100%). Three additional studies reported diagnostic metrics without AUROC variance and were synthesized narratively. Risk of bias was moderate to high in several domains, driven by selective cohorts, inconsistent reference standards, and incomplete reporting.
Conclusions: AI-ECG shows promise for the detection of HFpEF, but the current evidence base is predominantly retrospective, methodologically heterogeneous, and limited by variable reference standards and insufficient external validation. No prospective, outcome-based studies have yet established its clinical utility, and real-world implementation remains untested.
背景:保留射血分数的心力衰竭(HFpEF)约占心力衰竭的50%,随着人口年龄的增长和多病的增加,心力衰竭变得越来越普遍。诊断仍然具有挑战性,需要超声心动图、生物标志物和侵入性血流动力学等多模式检测。应用于心电图(AI-ECG)的人工智能提供了一种低成本、可扩展的方法,通过提取超出人类解释的模式来检测HFpEF。方法:我们按照PRISMA进行了系统评价和荟萃分析,并在PROSPERO进行了前瞻性注册。检索PubMed, Embase, Web of Science和IEEE explore,检索到2025年8月1日,评估AI/ML模型应用于ecg诊断HFpEF或左室舒张功能障碍(LVDD)的研究。符合条件的研究报告了与公认参考标准比较的诊断性能。采用QUADAS-AI评估偏倚风险。使用logit转换和随机效应模型汇总AUROC值,并对结果进行反向转换以提高可解释性。结果:10项研究(2021-2025)符合纳入标准,涵盖了来自不同人群的270,000名参与者。7项研究提供了足够的数据,共11个独立队列。合并的AUROC为0.84 (95% CI 0.78-0.88),表明有良好的区分能力,尽管异质性极端(I2 = 100%)。另外三个研究报告了没有AUROC方差的诊断指标,并进行了综合叙述。偏倚风险在几个领域是中等到高的,这是由选择性队列、不一致的参考标准和不完整的报告所驱动的。结论:AI-ECG有望检测HFpEF,但目前的证据基础主要是回顾性的,方法学上不一致,受参考标准变量和外部验证不足的限制。目前还没有前瞻性的、基于结果的研究证实其临床应用,现实世界的实施也尚未经过测试。
期刊介绍:
Cardiology Research and Practice is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies that focus on the diagnosis and treatment of cardiovascular disease. The journal welcomes submissions related to systemic hypertension, arrhythmia, congestive heart failure, valvular heart disease, vascular disease, congenital heart disease, and cardiomyopathy.