Yongxin Ma, Wei Chen, Lei Ren, Hounan Song, Kunyang Wang, Zhihui Qian, Xu Wang, Yao Zhang, Guowu Wei, Luquan Ren
{"title":"Design and Validation of a Bionic Variable Stiffness Semi-Active Ankle–Foot Prosthesis","authors":"Yongxin Ma, Wei Chen, Lei Ren, Hounan Song, Kunyang Wang, Zhihui Qian, Xu Wang, Yao Zhang, Guowu Wei, Luquan Ren","doi":"10.1007/s42235-026-00891-0","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Energy Storage and Return (ESR) prosthetic feet are commonly used by individuals with tibial amputations, but their fixed stiffness cannot accommodate varying walking tasks and user preferences. In contrast, semi-active prostheses can adjust stiffness through control mechanisms, though their design still leaves room for improvement in biomimetic characteristics, mass, and dynamic response. In this paper, we present a bionic, variable-stiffness, semi-active ankle–foot prosthesis. Stiffness is adjusted before each ground contact by controlling the motor to alter the length of the moment arm from the ankle joint center to the point of force application, with a range of 1.78–7.01 N·m/°. Additionally, the device features a biomimetic footplate design based on the transverse arch of the human foot, which reduces weight (total weight: 933 g) while guaranteeing support capacity. The prosthesis can precisely identify the phase for stiffness adjustment and achieve the widest range of adjustment during this phase. A unilateral tibial amputee participated in a preliminary clinical test involving variable-speed walking, stairs, and ramps. Preliminary single-subject data suggest that, compared to the subject's previous fixed-stiffness prosthesis, the newly designed prosthesis increases the range of motion, peak power, and energy storage during level walking, while reducing the adduction moment on the sound limb's knee joint. These findings offer initial support for the prosthesis' potential to improve the biomechanics of walking and other activities, providing insights for the development of biomimetic design.</p>\n </div>","PeriodicalId":614,"journal":{"name":"Journal of Bionic Engineering","volume":"23 3","pages":"1514 - 1533"},"PeriodicalIF":4.4000,"publicationDate":"2026-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Bionic Engineering","FirstCategoryId":"94","ListUrlMain":"https://link.springer.com/article/10.1007/s42235-026-00891-0","RegionNum":3,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Energy Storage and Return (ESR) prosthetic feet are commonly used by individuals with tibial amputations, but their fixed stiffness cannot accommodate varying walking tasks and user preferences. In contrast, semi-active prostheses can adjust stiffness through control mechanisms, though their design still leaves room for improvement in biomimetic characteristics, mass, and dynamic response. In this paper, we present a bionic, variable-stiffness, semi-active ankle–foot prosthesis. Stiffness is adjusted before each ground contact by controlling the motor to alter the length of the moment arm from the ankle joint center to the point of force application, with a range of 1.78–7.01 N·m/°. Additionally, the device features a biomimetic footplate design based on the transverse arch of the human foot, which reduces weight (total weight: 933 g) while guaranteeing support capacity. The prosthesis can precisely identify the phase for stiffness adjustment and achieve the widest range of adjustment during this phase. A unilateral tibial amputee participated in a preliminary clinical test involving variable-speed walking, stairs, and ramps. Preliminary single-subject data suggest that, compared to the subject's previous fixed-stiffness prosthesis, the newly designed prosthesis increases the range of motion, peak power, and energy storage during level walking, while reducing the adduction moment on the sound limb's knee joint. These findings offer initial support for the prosthesis' potential to improve the biomechanics of walking and other activities, providing insights for the development of biomimetic design.
期刊介绍:
The Journal of Bionic Engineering (JBE) is a peer-reviewed journal that publishes original research papers and reviews that apply the knowledge learned from nature and biological systems to solve concrete engineering problems. The topics that JBE covers include but are not limited to:
Mechanisms, kinematical mechanics and control of animal locomotion, development of mobile robots with walking (running and crawling), swimming or flying abilities inspired by animal locomotion.
Structures, morphologies, composition and physical properties of natural and biomaterials; fabrication of new materials mimicking the properties and functions of natural and biomaterials.
Biomedical materials, artificial organs and tissue engineering for medical applications; rehabilitation equipment and devices.
Development of bioinspired computation methods and artificial intelligence for engineering applications.