Sub-0.5-mm Resolution PET Versus Autoradiography: Comparison of mGluR1 Concentrations in Mouse Brain.

IF 9.1
Han Gyu Kang, Hideaki Tashima, Hidekatsu Wakizaka, Takeharu Minamihisamatsu, Tomoteru Yamasaki, Masayuki Fujinaga, Ming-Rong Zhang, Makoto Higuchi, Taiga Yamaya
{"title":"Sub-0.5-mm Resolution PET Versus Autoradiography: Comparison of mGluR1 Concentrations in Mouse Brain.","authors":"Han Gyu Kang, Hideaki Tashima, Hidekatsu Wakizaka, Takeharu Minamihisamatsu, Tomoteru Yamasaki, Masayuki Fujinaga, Ming-Rong Zhang, Makoto Higuchi, Taiga Yamaya","doi":"10.2967/jnumed.125.271600","DOIUrl":null,"url":null,"abstract":"<p><p>For mouse brain PET imaging with high quantification accuracy, ultrahigh resolution is essential. Metabotropic glutamate receptors are important molecular targets, linked to various neurologic diseases. Here, we report the comparison of in vivo mouse brain images obtained with sub-0.5-mm resolution PET and those obtained with autoradiography using 4-<sup>18</sup>F-fluoro-<i>N</i>-[4-[6-(isopropylamino)pyrimidin-4-yl]-1,3-thiazol-2-yl]-<i>N</i>-methylbenzamide (<sup>18</sup>F-FITM) that binds to metabotropic glutamate receptor subtype 1. <b>Methods:</b> We recently developed a sub-0.5-mm resolution PET scanner having an axial coverage of 23.4 mm and an inner diameter of 48 mm. The PET scanner comprises 32 depth-of-interaction detectors, each of which has staggered 3-layer lutetium-yttrium-orthosilicate crystal arrays with a pitch of 0.8 mm. A resolution phantom was used to evaluate the imaging performance of the PET scanner. Dynamic PET imaging was performed to evaluate the concentration changes of <sup>18</sup>F-FITM at various mouse brain regions. In vivo metabotropic glutamate receptor imaging of a mouse brain was performed using <sup>18</sup>F-FITM and the PET scanner. Subsequently, autoradiography images of the same mouse brain were obtained using <sup>18</sup>F-FITM. <b>Results:</b> The 0.45-mm rod structure was resolved with the PET scanner. Time-activity curves of various mouse brain regions were obtained. The sub-0.5-mm resolution PET visualized <sup>18</sup>F-FITM uptake in the mouse brain with high correlation to the autoradiography images. <b>Conclusion:</b> The sub-0.5-mm resolution PET opens up new opportunities for translational neuroscience research using mice models.</p>","PeriodicalId":94099,"journal":{"name":"Journal of nuclear medicine : official publication, Society of Nuclear Medicine","volume":" ","pages":"1503-1509"},"PeriodicalIF":9.1000,"publicationDate":"2026-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13544212/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine : official publication, Society of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnumed.125.271600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For mouse brain PET imaging with high quantification accuracy, ultrahigh resolution is essential. Metabotropic glutamate receptors are important molecular targets, linked to various neurologic diseases. Here, we report the comparison of in vivo mouse brain images obtained with sub-0.5-mm resolution PET and those obtained with autoradiography using 4-18F-fluoro-N-[4-[6-(isopropylamino)pyrimidin-4-yl]-1,3-thiazol-2-yl]-N-methylbenzamide (18F-FITM) that binds to metabotropic glutamate receptor subtype 1. Methods: We recently developed a sub-0.5-mm resolution PET scanner having an axial coverage of 23.4 mm and an inner diameter of 48 mm. The PET scanner comprises 32 depth-of-interaction detectors, each of which has staggered 3-layer lutetium-yttrium-orthosilicate crystal arrays with a pitch of 0.8 mm. A resolution phantom was used to evaluate the imaging performance of the PET scanner. Dynamic PET imaging was performed to evaluate the concentration changes of 18F-FITM at various mouse brain regions. In vivo metabotropic glutamate receptor imaging of a mouse brain was performed using 18F-FITM and the PET scanner. Subsequently, autoradiography images of the same mouse brain were obtained using 18F-FITM. Results: The 0.45-mm rod structure was resolved with the PET scanner. Time-activity curves of various mouse brain regions were obtained. The sub-0.5-mm resolution PET visualized 18F-FITM uptake in the mouse brain with high correlation to the autoradiography images. Conclusion: The sub-0.5-mm resolution PET opens up new opportunities for translational neuroscience research using mice models.

低于0.5 mm分辨率PET与放射自显像:小鼠脑内mGluR1浓度的比较。
对于具有高定量精度的小鼠脑PET成像,超高分辨率是必不可少的。代谢性谷氨酸受体是重要的分子靶点,与多种神经系统疾病有关。在这里,我们报告了用低于0.5 mm分辨率的PET获得的活体小鼠脑图像与使用4- 18f -氟- n-[4-[6-(异丙胺)嘧啶-4-基]-1,3-噻唑-2-基]- n-甲基苄胺(18F-FITM)结合代谢促谷氨酸受体亚型1的放射自显影获得的图像的比较。方法:我们最近开发了一种分辨率低于0.5 mm的PET扫描仪,轴向覆盖23.4 mm,内径48 mm。PET扫描仪包括32个相互作用深度探测器,每个探测器都有交错的3层镥钇正硅酸盐晶体阵列,间距为0.8 mm。采用分辨率模型对PET扫描仪的成像性能进行评价。采用动态PET显像评价小鼠各脑区18F-FITM的浓度变化。使用18F-FITM和PET扫描仪对小鼠大脑进行体内代谢性谷氨酸受体成像。随后,使用18F-FITM获得同一小鼠大脑的放射自显影图像。结果:PET扫描可分辨出0.45 mm的棒状结构。得到小鼠各脑区时间-活动曲线。分辨率低于0.5 mm的PET显示小鼠脑内18F-FITM摄取与放射自显影图像高度相关。结论:分辨率低于0.5 mm的PET为利用小鼠模型进行转化神经科学研究开辟了新的机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书