Influence of Fiber Dispersion Representation on the Accuracy of the Mechanical Response of Healthy and Aneurysmal Aortic Wall Tissue

IF 2.1 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Omid Ghorbani, Victorien Prot, Gerhard A. Holzapfel, Bjørn Skallerud
{"title":"Influence of Fiber Dispersion Representation on the Accuracy of the Mechanical Response of Healthy and Aneurysmal Aortic Wall Tissue","authors":"Omid Ghorbani,&nbsp;Victorien Prot,&nbsp;Gerhard A. Holzapfel,&nbsp;Bjørn Skallerud","doi":"10.1002/cnm.70186","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>This study investigates the influence of fiber dispersion representation on the accuracy of the mechanical response of anisotropic hyperelastic material models for healthy and aneurysmal human aortic wall tissue under planar biaxial loading. Five fitting strategies were compared: (i) detailed integration of fiber orientation and dispersion data across the thickness; (ii) a single, thickness-averaged fiber distribution; (iii) two representative layers (media and adventitia); (iv) multiple layers discretized in the radial direction; and (v) a single layer with a symmetrical in-plane distribution of collagen fibers. The goodness of fit was calculated using the coefficient of determination averaged over all experimental tests. The most accurate fits were achieved with strategy (i), with a goodness of fit <span></span><math>\n <semantics>\n <mrow>\n <msubsup>\n <mi>R</mi>\n <mi>avg</mi>\n <mn>2</mn>\n </msubsup>\n <mo>≈</mo>\n <mn>0.96</mn>\n <mo>±</mo>\n <mn>0.02</mn>\n </mrow>\n <annotation>$$ {R}_{\\mathrm{avg}}^2\\approx 0.96\\pm 0.02 $$</annotation>\n </semantics></math> for the combined cohort of aneurysm patients and the healthy cohort; comparable accuracy was achieved by the two-layer model (iii), <span></span><math>\n <semantics>\n <mrow>\n <msubsup>\n <mi>R</mi>\n <mi>avg</mi>\n <mn>2</mn>\n </msubsup>\n <mo>≈</mo>\n <mn>0.91</mn>\n <mo>±</mo>\n <mn>0.06</mn>\n </mrow>\n <annotation>$$ {R}_{\\mathrm{avg}}^2\\approx 0.91\\pm 0.06 $$</annotation>\n </semantics></math>, but with significantly less complexity in model implementation. As a secondary objective of this study, regional parameters that correlate with the two-layer model (iii) and are intended for finite element analyses are presented. The method using a symmetrical single layer in model (v) yielded the lowest accuracy, <span></span><math>\n <semantics>\n <mrow>\n <msubsup>\n <mi>R</mi>\n <mi>avg</mi>\n <mn>2</mn>\n </msubsup>\n <mo>≈</mo>\n <mn>0.73</mn>\n <mo>±</mo>\n <mn>0.14</mn>\n </mrow>\n <annotation>$$ {R}_{\\mathrm{avg}}^2\\approx 0.73\\pm 0.14 $$</annotation>\n </semantics></math>, and highlighted the need to capture non-symmetric fiber families. The modeling of elastin as a separate anisotropic material was also investigated by comparing two different constitutive modeling approaches. While the healthy cohort showed the best fit by including elastin in model (i) (<span></span><math>\n <semantics>\n <mrow>\n <msubsup>\n <mi>R</mi>\n <mi>avg</mi>\n <mn>2</mn>\n </msubsup>\n <mo>≈</mo>\n <mn>0.99</mn>\n <mo>±</mo>\n <mn>0.01</mn>\n </mrow>\n <annotation>$$ {R}_{\\mathrm{avg}}^2\\approx 0.99\\pm 0.01 $$</annotation>\n </semantics></math>), separate treatment of elastin in the combined cohorts resulted in only a slight increase of <span></span><math>\n <semantics>\n <mrow>\n <msubsup>\n <mi>R</mi>\n <mi>avg</mi>\n <mn>2</mn>\n </msubsup>\n </mrow>\n <annotation>$$ {R}_{\\mathrm{avg}}^2 $$</annotation>\n </semantics></math> of <span></span><math>\n <semantics>\n <mrow>\n <mo>≈</mo>\n <mn>0.02</mn>\n </mrow>\n <annotation>$$ \\approx 0.02 $$</annotation>\n </semantics></math>. This marginal improvement is offset by the risk of overfitting due to additional parameters, which supports the inclusion of elastin in the ground matrix.</p>\n </div>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"42 6","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2026-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70186","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates the influence of fiber dispersion representation on the accuracy of the mechanical response of anisotropic hyperelastic material models for healthy and aneurysmal human aortic wall tissue under planar biaxial loading. Five fitting strategies were compared: (i) detailed integration of fiber orientation and dispersion data across the thickness; (ii) a single, thickness-averaged fiber distribution; (iii) two representative layers (media and adventitia); (iv) multiple layers discretized in the radial direction; and (v) a single layer with a symmetrical in-plane distribution of collagen fibers. The goodness of fit was calculated using the coefficient of determination averaged over all experimental tests. The most accurate fits were achieved with strategy (i), with a goodness of fit R avg 2 ≈ 0.96 ± 0.02 $$ {R}_{\mathrm{avg}}^2\approx 0.96\pm 0.02 $$ for the combined cohort of aneurysm patients and the healthy cohort; comparable accuracy was achieved by the two-layer model (iii), R avg 2 ≈ 0.91 ± 0.06 $$ {R}_{\mathrm{avg}}^2\approx 0.91\pm 0.06 $$ , but with significantly less complexity in model implementation. As a secondary objective of this study, regional parameters that correlate with the two-layer model (iii) and are intended for finite element analyses are presented. The method using a symmetrical single layer in model (v) yielded the lowest accuracy, R avg 2 ≈ 0.73 ± 0.14 $$ {R}_{\mathrm{avg}}^2\approx 0.73\pm 0.14 $$ , and highlighted the need to capture non-symmetric fiber families. The modeling of elastin as a separate anisotropic material was also investigated by comparing two different constitutive modeling approaches. While the healthy cohort showed the best fit by including elastin in model (i) ( R avg 2 ≈ 0.99 ± 0.01 $$ {R}_{\mathrm{avg}}^2\approx 0.99\pm 0.01 $$ ), separate treatment of elastin in the combined cohorts resulted in only a slight increase of R avg 2 $$ {R}_{\mathrm{avg}}^2 $$ of ≈ 0.02 $$ \approx 0.02 $$ . This marginal improvement is offset by the risk of overfitting due to additional parameters, which supports the inclusion of elastin in the ground matrix.

Abstract Image

纤维弥散度表征对健康和动脉瘤性主动脉壁组织力学响应准确性的影响。
本研究探讨了在平面双轴载荷下,纤维色散表示对健康和动脉瘤性人主动脉壁组织各向异性超弹性材料模型力学响应准确性的影响。比较了五种拟合策略:(i)在厚度上详细整合纤维取向和色散数据;(ii)单一、厚度平均的纤维分布;(iii)两个代表性层(中膜和外膜);(iv)径向离散的多层;(v)胶原纤维在平面内对称分布的单层结构。拟合优度是用决定系数对所有实验测试取平均值来计算的。采用策略(i)获得最准确的拟合,动脉瘤患者联合队列与健康队列的拟合优度ravg 2≈0.96±0.02 $$ {R}_{\mathrm{avg}}^2\approx 0.96\pm 0.02 $$;两层模型(iii)的精度相当,ravg 2≈0.91±0.06 $$ {R}_{\mathrm{avg}}^2\approx 0.91\pm 0.06 $$,但模型实现的复杂性明显降低。作为本研究的次要目标,提出了与两层模型(iii)相关的区域参数,用于有限元分析。在模型(v)中使用对称单层的方法获得了最低的精度,ravg 2≈0.73±0.14 $$ {R}_{\mathrm{avg}}^2\approx 0.73\pm 0.14 $$,并强调了捕获非对称光纤族的必要性。通过比较两种不同的本构建模方法,研究了弹性蛋白作为一种单独的各向异性材料的建模。健康队列在模型(i)中加入弹性蛋白显示出最佳拟合(ravg2≈0.99±0.01 $$ {R}_{\mathrm{avg}}^2\approx 0.99\pm 0.01 $$),而在联合队列中单独处理弹性蛋白仅导致ravg2略微增加$$ {R}_{\mathrm{avg}}^2 $$≈0.02 $$ \approx 0.02 $$。这种边际改进被额外参数导致的过拟合风险所抵消,这些参数支持将弹性蛋白包含在地面矩阵中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书