Predicting clinical efficacy of lung gene delivery in people with cystic fibrosis: which in vitro and in vivo models best predict outcomes in human lungs?
Miftakul Munir, Jeremy Wiyana, Rhiannon B Werder, Neville J Butcher, Rachel Burow, Alexandra McCarron, Qichen Yu, Shafagh A Waters, Lisa M Kaminskas
{"title":"Predicting clinical efficacy of lung gene delivery in people with cystic fibrosis: which <i>in vitro</i> and <i>in vivo</i> models best predict outcomes in human lungs?","authors":"Miftakul Munir, Jeremy Wiyana, Rhiannon B Werder, Neville J Butcher, Rachel Burow, Alexandra McCarron, Qichen Yu, Shafagh A Waters, Lisa M Kaminskas","doi":"10.1080/17425247.2026.2684641","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Despite over three-decades of work, no inhalable nucleic acid delivery system for cystic fibrosis (CF) has advanced beyond Phase II due to a lack of congruence between positive outcomes from <i>in vitro</i> and preclinical work, and lung function improvements in people with CF.</p><p><strong>Areas covered: </strong>We review publications covering <i>in vitro</i> and <i>in vivo</i> animal models for CF research from databases including Web of Science and PubMed. Data were used to evaluate the performance of inhaled nucleic acid delivery systems for CF and examine why positive outcomes in these models fail to predict clinical responses.</p><p><strong>Expert opinion: </strong>The field should recalibrate expectations regarding the proportion of epithelial cell correction required for meaningful clinical improvement since the threshold for sustained improvement in lung function in humans may be substantially higher. No single model can predict clinical responses. Translation robustness depends on integrating multiple systems that collectively interrogate delivery, persistence, safety and functional restoration of lung function in clinically meaningful settings. Appropriate <i>in vitro</i> air-liquid interface models that accurately recapitulate the CF airways are important starting points, followed by delivery and functional evaluation in CF animal models that closely resemble human lung physiology and disease phenotype, including pigs and ferrets.</p>","PeriodicalId":94004,"journal":{"name":"Expert opinion on drug delivery","volume":" ","pages":"1531-1549"},"PeriodicalIF":5.4000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert opinion on drug delivery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17425247.2026.2684641","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Despite over three-decades of work, no inhalable nucleic acid delivery system for cystic fibrosis (CF) has advanced beyond Phase II due to a lack of congruence between positive outcomes from in vitro and preclinical work, and lung function improvements in people with CF.
Areas covered: We review publications covering in vitro and in vivo animal models for CF research from databases including Web of Science and PubMed. Data were used to evaluate the performance of inhaled nucleic acid delivery systems for CF and examine why positive outcomes in these models fail to predict clinical responses.
Expert opinion: The field should recalibrate expectations regarding the proportion of epithelial cell correction required for meaningful clinical improvement since the threshold for sustained improvement in lung function in humans may be substantially higher. No single model can predict clinical responses. Translation robustness depends on integrating multiple systems that collectively interrogate delivery, persistence, safety and functional restoration of lung function in clinically meaningful settings. Appropriate in vitro air-liquid interface models that accurately recapitulate the CF airways are important starting points, followed by delivery and functional evaluation in CF animal models that closely resemble human lung physiology and disease phenotype, including pigs and ferrets.
导读:尽管经过了30多年的研究,但由于体外和临床前研究的阳性结果缺乏一致性,以及CF患者肺功能的改善,囊性纤维化(CF)的可吸入核酸输送系统尚未超过II期。研究领域:我们回顾了来自Web of Science和PubMed等数据库的CF研究的体外和体内动物模型的出版物。数据被用来评估吸入核酸输送系统治疗CF的性能,并检查为什么这些模型的阳性结果不能预测临床反应。专家意见:该领域应该重新调整对有意义的临床改善所需的上皮细胞校正比例的期望,因为人类肺功能持续改善的门槛可能要高得多。没有单一的模型可以预测临床反应。翻译稳健性取决于整合多个系统,这些系统在临床有意义的环境中共同询问肺功能的传递、持久性、安全性和功能恢复。适当的体外气液界面模型是重要的起点,它能准确地概括CF气道,其次是在CF动物模型中进行传递和功能评估,这些动物模型与人类肺生理和疾病表型非常相似,包括猪和雪貂。