M S Koch, D R Zwahlen, A Clivio, M Bendahman, D Benzaquen, M Betz, P Canino, D Correia, B De Bari, O Fargier Bochaton, T Finazzi, M Gau, G Gruber, R Gräter, G Henke, E Herrmann, K Khanfir, R Krcek, K Lössl, T Mader, O Matzinger, L Negretti, C Panje, N Péguret, L Plasswilm, P Tsoutsou, F Zimmermann, C Oehler
{"title":"Thyroid dose guidance in elective supraclavicular breast radiotherapy: a national survey of practice patterns in Switzerland.","authors":"M S Koch, D R Zwahlen, A Clivio, M Bendahman, D Benzaquen, M Betz, P Canino, D Correia, B De Bari, O Fargier Bochaton, T Finazzi, M Gau, G Gruber, R Gräter, G Henke, E Herrmann, K Khanfir, R Krcek, K Lössl, T Mader, O Matzinger, L Negretti, C Panje, N Péguret, L Plasswilm, P Tsoutsou, F Zimmermann, C Oehler","doi":"10.1007/s00066-026-02557-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Supraclavicular fossa (SCF) irradiation is integral to adjuvant radiotherapy (RT) for node-positive breast cancer. Due to anatomical proximity, the thyroid gland is frequently exposed, leading to hypothyroidism in approximately 20-40% of long-term survivors. Despite robust dose-response evidence, thyroid management remains inconsistent and breast cancer-specific dose guidance is lacking. This nationwide survey evaluated current practice patterns regarding thyroid delineation, SCF contouring, and thyroid dose guidance during elective SCF irradiation in Switzerland.</p><p><strong>Methods: </strong>A structured electronic questionnaire was distributed between May and November 2025 to all 30 Swiss radiation oncology centers treating breast cancer. Institutional characteristics, thyroid contouring practices, SCF target delineation, and applied thyroid dose guidance were assessed. Analyses were descriptive only.</p><p><strong>Results: </strong>Thirty-three responses from 25 of 30 centers (83%), including all university hospitals, were analyzed. Modern RT techniques were widely implemented (VMAT 79%, IMRT 15%). Routine thyroid contouring was reported by 91% of respondents, of which 94% used AI-assisted tools. However, only 55% applied explicit thyroid dose guidance. Reported mean thyroid dose (D<sub>mean</sub>) thresholds ranged from 12 to 35 Gy and clustered at 13.5-15 Gy, 20-21 Gy, and 30-32 Gy. Excluding ALARA (\"as low as reasonably achievable\") responses, the median D<sub>mean</sub> guidance was 21 Gy (IQR 16-30 Gy). SCF delineation varied substantially, particularly regarding superior and medial margins, and 64% reported CTV/PTV cropping to reduce thyroid dose.</p><p><strong>Conclusions: </strong>Despite strong dose-response evidence and widespread availability of advanced RT techniques, thyroid protection during elective SCF irradiation remains inconsistently implemented. These findings reveal a gap between evidence and practice and support the development of harmonized, breast cancer-specific recommendations, including routine thyroid delineation, anatomy-based SCF contouring, and explicit, oncologically safe dose guidance-particularly D<sub>mean</sub> targets of ≤ 13.5 Gy, with ≤20-21 Gy as a pragmatic upper limit-to reduce radiation-induced hypothyroidism without compromising cancer control.</p>","PeriodicalId":21998,"journal":{"name":"Strahlentherapie und Onkologie","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2026-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strahlentherapie und Onkologie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00066-026-02557-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Supraclavicular fossa (SCF) irradiation is integral to adjuvant radiotherapy (RT) for node-positive breast cancer. Due to anatomical proximity, the thyroid gland is frequently exposed, leading to hypothyroidism in approximately 20-40% of long-term survivors. Despite robust dose-response evidence, thyroid management remains inconsistent and breast cancer-specific dose guidance is lacking. This nationwide survey evaluated current practice patterns regarding thyroid delineation, SCF contouring, and thyroid dose guidance during elective SCF irradiation in Switzerland.
Methods: A structured electronic questionnaire was distributed between May and November 2025 to all 30 Swiss radiation oncology centers treating breast cancer. Institutional characteristics, thyroid contouring practices, SCF target delineation, and applied thyroid dose guidance were assessed. Analyses were descriptive only.
Results: Thirty-three responses from 25 of 30 centers (83%), including all university hospitals, were analyzed. Modern RT techniques were widely implemented (VMAT 79%, IMRT 15%). Routine thyroid contouring was reported by 91% of respondents, of which 94% used AI-assisted tools. However, only 55% applied explicit thyroid dose guidance. Reported mean thyroid dose (Dmean) thresholds ranged from 12 to 35 Gy and clustered at 13.5-15 Gy, 20-21 Gy, and 30-32 Gy. Excluding ALARA ("as low as reasonably achievable") responses, the median Dmean guidance was 21 Gy (IQR 16-30 Gy). SCF delineation varied substantially, particularly regarding superior and medial margins, and 64% reported CTV/PTV cropping to reduce thyroid dose.
Conclusions: Despite strong dose-response evidence and widespread availability of advanced RT techniques, thyroid protection during elective SCF irradiation remains inconsistently implemented. These findings reveal a gap between evidence and practice and support the development of harmonized, breast cancer-specific recommendations, including routine thyroid delineation, anatomy-based SCF contouring, and explicit, oncologically safe dose guidance-particularly Dmean targets of ≤ 13.5 Gy, with ≤20-21 Gy as a pragmatic upper limit-to reduce radiation-induced hypothyroidism without compromising cancer control.
期刊介绍:
Strahlentherapie und Onkologie, published monthly, is a scientific journal that covers all aspects of oncology with focus on radiooncology, radiation biology and radiation physics. The articles are not only of interest to radiooncologists but to all physicians interested in oncology, to radiation biologists and radiation physicists. The journal publishes original articles, review articles and case studies that are peer-reviewed. It includes scientific short communications as well as a literature review with annotated articles that inform the reader on new developments in the various disciplines concerned and hence allow for a sound overview on the latest results in radiooncology research.
Founded in 1912, Strahlentherapie und Onkologie is the oldest oncological journal in the world. Today, contributions are published in English and German. All articles have English summaries and legends. The journal is the official publication of several scientific radiooncological societies and publishes the relevant communications of these societies.