Hybrid CEEMDAN–deep learning models for COD prediction in wastewater treatment plants

IF 3.5 4区 环境科学与生态学 Q3 ENGINEERING, ENVIRONMENTAL
Saeed Samadianfard, Egemen Aras, Damla Yılmaz Çelik, Mohammad Taghi Sattari and Orhan Gündüz
{"title":"Hybrid CEEMDAN–deep learning models for COD prediction in wastewater treatment plants","authors":"Saeed Samadianfard, Egemen Aras, Damla Yılmaz Çelik, Mohammad Taghi Sattari and Orhan Gündüz","doi":"10.1039/D6EW00014B","DOIUrl":null,"url":null,"abstract":"<p >Precise and timely chemical oxygen demand (COD) prediction is key to regulatory compliance and process control in a full-scale wastewater treatment, but laboratory assays and sluggish online measurements hinder responsiveness. Thus, a deployment-conceived hybrid pipeline for near-term COD predictions is proposed in this study. This method introduces a deployment-oriented hybrid framework that integrates complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN), gated recurrent units (GRU), and a multi-objective observer-teacher-learner-based optimizer (MOOTLBO) for near-term COD forecasting. Daily measurements from the Gebze municipal wastewater treatment plant (Türkiye) between 2019 and 2023 were collected from regularly available measured data together with total suspended solids, total nitrogen, total phosphorus, and pH with statistically enlightened lags to encode process memory. Intrinsic mode functions were obtained from the COD series with the application of CEEMDAN, and the intrinsic mode functions were concatenated with exogenous features and forwarded to recurrent learners. Long short-term memory (LSTM) and gated recurrent units (GRU) were studied as two potential configurations in the study. Hyperparameters were optimized with a multi-objective observer-teacher-learner optimizer (MOOTLBO) in order to balance fidelity, parsimony, and training cost. Evaluation occurred on a held-out test set (80/20 partition) with RMSE, MAE, <em>R</em><small><sup>2</sup></small>, MAPE, MBE, and KGE metrics. Across alternatives, decomposition-then-learn decreased error compared with non-decomposed baselines. A CEEMDAN–GRU variant turned out to be the most accurate configuration, which reached good performance with RMSE = 2.84 mg L<small><sup>−1</sup></small>, MAE = 2.28 mg L<small><sup>−1</sup></small>, <em>R</em><small><sup>2</sup></small> = 0.9999, MAPE = 0.46%, MBE = 1.47 mg L<small><sup>−1</sup></small>, and KGE = 0.9974. In an optimized CEEMDAN–GRU–MOOTLBO configuration, similarly strong accuracy (RMSE = 4.19 mg L<small><sup>−1</sup></small>, MAE = 2.66 mg L<small><sup>−1</sup></small>, <em>R</em><small><sup>2</sup></small> = 0.9999, MAPE = 0.52%, MBE = 0.16 mg L<small><sup>−1</sup></small>, KGE = 0.9997) was obtained with excellent bias control. In view of accuracy, stability, and runtime, the CEEMDAN–GRU family represents the most suitable choice for real-time soft sensing of COD, facilitating proactive control and early warning with the presence of changing influent conditions in challenging plant practice.</p>","PeriodicalId":75,"journal":{"name":"Environmental Science: Water Research & Technology","volume":" 6","pages":" 1872-1894"},"PeriodicalIF":3.5000,"publicationDate":"2026-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2026/ew/d6ew00014b?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science: Water Research & Technology","FirstCategoryId":"93","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ew/d6ew00014b","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Precise and timely chemical oxygen demand (COD) prediction is key to regulatory compliance and process control in a full-scale wastewater treatment, but laboratory assays and sluggish online measurements hinder responsiveness. Thus, a deployment-conceived hybrid pipeline for near-term COD predictions is proposed in this study. This method introduces a deployment-oriented hybrid framework that integrates complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN), gated recurrent units (GRU), and a multi-objective observer-teacher-learner-based optimizer (MOOTLBO) for near-term COD forecasting. Daily measurements from the Gebze municipal wastewater treatment plant (Türkiye) between 2019 and 2023 were collected from regularly available measured data together with total suspended solids, total nitrogen, total phosphorus, and pH with statistically enlightened lags to encode process memory. Intrinsic mode functions were obtained from the COD series with the application of CEEMDAN, and the intrinsic mode functions were concatenated with exogenous features and forwarded to recurrent learners. Long short-term memory (LSTM) and gated recurrent units (GRU) were studied as two potential configurations in the study. Hyperparameters were optimized with a multi-objective observer-teacher-learner optimizer (MOOTLBO) in order to balance fidelity, parsimony, and training cost. Evaluation occurred on a held-out test set (80/20 partition) with RMSE, MAE, R2, MAPE, MBE, and KGE metrics. Across alternatives, decomposition-then-learn decreased error compared with non-decomposed baselines. A CEEMDAN–GRU variant turned out to be the most accurate configuration, which reached good performance with RMSE = 2.84 mg L−1, MAE = 2.28 mg L−1, R2 = 0.9999, MAPE = 0.46%, MBE = 1.47 mg L−1, and KGE = 0.9974. In an optimized CEEMDAN–GRU–MOOTLBO configuration, similarly strong accuracy (RMSE = 4.19 mg L−1, MAE = 2.66 mg L−1, R2 = 0.9999, MAPE = 0.52%, MBE = 0.16 mg L−1, KGE = 0.9997) was obtained with excellent bias control. In view of accuracy, stability, and runtime, the CEEMDAN–GRU family represents the most suitable choice for real-time soft sensing of COD, facilitating proactive control and early warning with the presence of changing influent conditions in challenging plant practice.

Abstract Image

混合ceemdan -深度学习模型用于污水处理厂COD预测
准确和及时的化学需氧量(COD)预测是全面废水处理中符合法规和过程控制的关键,但实验室分析和缓慢的在线测量阻碍了响应。因此,本研究提出了一种部署构思的混合管道,用于近期COD预测。该方法引入了一个面向部署的混合框架,该框架集成了具有自适应噪声的完整集成经验模式分解(CEEMDAN)、门控循环单元(GRU)和用于近期COD预测的基于观察者-教师-学习者的多目标优化器(MOOTLBO)。2019年至2023年,格布泽城市污水处理厂(t rkiye)的日常测量数据与总悬浮固体、总氮、总磷和pH值一起收集,统计滞后以编码过程记忆。应用CEEMDAN从COD序列中获得本征模态函数,并将本征模态函数与外生特征连接,转发给循环学习器。长短期记忆(LSTM)和门控循环单元(GRU)作为两种可能的配置进行了研究。采用多目标观察者-教师-学习者优化器(MOOTLBO)对超参数进行优化,以平衡逼真度、简约性和训练成本。使用RMSE、MAE、R2、MAPE、MBE和KGE指标在一个固定测试集(80/20分区)上进行评估。在各种替代方案中,与未分解的基线相比,分解后学习减少了误差。CEEMDAN-GRU变体配置最准确,RMSE = 2.84 mg L−1,MAE = 2.28 mg L−1,R2 = 0.9999, MAPE = 0.46%, MBE = 1.47 mg L−1,KGE = 0.9974。在优化的CEEMDAN-GRU-MOOTLBO配置中,获得了同样高的准确度(RMSE = 4.19 mg L−1,MAE = 2.66 mg L−1,R2 = 0.9999, MAPE = 0.52%, MBE = 0.16 mg L−1,KGE = 0.9997),并具有良好的偏倚控制。考虑到准确性、稳定性和运行时间,CEEMDAN-GRU系列代表了COD实时软测量的最合适选择,有助于在具有挑战性的工厂实践中对进水条件变化进行主动控制和预警。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Environmental Science: Water Research & Technology
Environmental Science: Water Research & Technology ENGINEERING, ENVIRONMENTALENVIRONMENTAL SC-ENVIRONMENTAL SCIENCES
CiteScore
8.60
自引率
4.00%
发文量
206
期刊介绍: Environmental Science: Water Research & Technology seeks to showcase high quality research about fundamental science, innovative technologies, and management practices that promote sustainable water.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书