Republication de : Extended high-frequency audiometry for detecting early hearing effects of personal listening devices: A narrative review

Q4 Medicine
M. Škerková , E. Mrázková , M. Kovalová , L. Kocurková , N. Gottfriedová
{"title":"Republication de : Extended high-frequency audiometry for detecting early hearing effects of personal listening devices: A narrative review","authors":"M. Škerková ,&nbsp;E. Mrázková ,&nbsp;M. Kovalová ,&nbsp;L. Kocurková ,&nbsp;N. Gottfriedová","doi":"10.1016/j.aforl.2026.04.004","DOIUrl":null,"url":null,"abstract":"<div><div>Personal listening devices (PLDs) are widely used among young adults, raising concern about early noise-induced hearing loss (NIHL). Conventional audiometry (≤<!--> <!-->8<!--> <!-->kHz) may not detect the earliest signs of cochlear damage. Extended high-frequency audiometry (EHFA, ≥<!--> <!-->9<!--> <!-->kHz) has been suggested as a more sensitive approach for identifying early auditory changes. This narrative review examined the potential role of EHFA in detecting PLD-related hearing effects. A structured search of PubMed and Academic Search Ultimate through 30 September 2024 identified nine eligible studies (sample sizes 20–282; ages 13–31 years). Most studies reported significantly elevated thresholds in the 9–16<!--> <!-->kHz range, particularly at 12–14<!--> <!-->kHz, among participants with prolonged PLD use (&gt;<!--> <!-->4–5 years) or higher listening levels (≥<!--> <!-->75 dBA). These threshold shifts often occurred despite normal conventional audiograms, suggesting that EHFA may capture early changes not identified by standard testing. Two studies, however, found no significant group differences, likely due to small control samples, short exposure duration, or limited statistical power. Considerable heterogeneity in exposure definitions, calibration, and reliance on self-reported listening habits further limits comparability. Current evidence indicates that EHFA may hold promise as an early indicator of NIHL in young adult PLD users, but further methodological refinements, objective exposure monitoring, and longitudinal research are required to establish normative data and clarify its prognostic and clinical utility.</div></div>","PeriodicalId":38853,"journal":{"name":"Annales Francaises d''Oto-Rhino-Laryngologie et de Pathologie Cervico-Faciale","volume":"143 3","pages":"Pages 210-214"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales Francaises d''Oto-Rhino-Laryngologie et de Pathologie Cervico-Faciale","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S187972612600104X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/4 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Personal listening devices (PLDs) are widely used among young adults, raising concern about early noise-induced hearing loss (NIHL). Conventional audiometry (≤ 8 kHz) may not detect the earliest signs of cochlear damage. Extended high-frequency audiometry (EHFA, ≥ 9 kHz) has been suggested as a more sensitive approach for identifying early auditory changes. This narrative review examined the potential role of EHFA in detecting PLD-related hearing effects. A structured search of PubMed and Academic Search Ultimate through 30 September 2024 identified nine eligible studies (sample sizes 20–282; ages 13–31 years). Most studies reported significantly elevated thresholds in the 9–16 kHz range, particularly at 12–14 kHz, among participants with prolonged PLD use (> 4–5 years) or higher listening levels (≥ 75 dBA). These threshold shifts often occurred despite normal conventional audiograms, suggesting that EHFA may capture early changes not identified by standard testing. Two studies, however, found no significant group differences, likely due to small control samples, short exposure duration, or limited statistical power. Considerable heterogeneity in exposure definitions, calibration, and reliance on self-reported listening habits further limits comparability. Current evidence indicates that EHFA may hold promise as an early indicator of NIHL in young adult PLD users, but further methodological refinements, objective exposure monitoring, and longitudinal research are required to establish normative data and clarify its prognostic and clinical utility.
用于检测个人听力设备早期听力效果的扩展高频测听术:叙述性回顾
个人助听器在年轻人中广泛使用,引起了人们对早期噪声性听力损失的关注。常规听力学(≤8千赫)可能无法检测到耳蜗损伤的最早迹象。扩展高频测听(EHFA,≥9 kHz)被认为是识别早期听觉变化的更敏感的方法。本文综述了EHFA在检测pld相关听力效应中的潜在作用。在2024年9月30日之前对PubMed和Academic search Ultimate进行结构化检索,确定了9项符合条件的研究(样本量20-282,年龄13-31岁)。大多数研究报告,在长期使用PLD(4-5年)或较高听力水平(≥75 dBA)的参与者中,9-16 kHz范围内的阈值显著升高,特别是12-14 kHz。尽管常规听力图正常,但这些阈值变化经常发生,这表明EHFA可能捕捉到标准测试无法识别的早期变化。然而,两项研究没有发现显著的组间差异,可能是由于对照样本小、暴露时间短或统计效力有限。在暴露定义、校准和对自我报告的听力习惯的依赖方面,相当大的异质性进一步限制了可比性。目前的证据表明,EHFA可能有望作为年轻成年PLD使用者NIHL的早期指标,但需要进一步的方法改进、客观暴露监测和纵向研究来建立规范数据,并阐明其预后和临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
93
审稿时长
51 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书