Nanostructured electrode materials and flexible-substrate engineering for wearable multi-analyte biosensors in diabetes monitoring and personalized care: a comprehensive review

IF 4.7 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Roghieh Sodeify, Mir Amirhossein Seyednazari, Amir Mohammad Dorosti, Alireza Nourazarian
{"title":"Nanostructured electrode materials and flexible-substrate engineering for wearable multi-analyte biosensors in diabetes monitoring and personalized care: a comprehensive review","authors":"Roghieh Sodeify,&nbsp;Mir Amirhossein Seyednazari,&nbsp;Amir Mohammad Dorosti,&nbsp;Alireza Nourazarian","doi":"10.1007/s10856-026-07070-x","DOIUrl":null,"url":null,"abstract":"<div><p>This review examines the convergence of wearable biosensors and artificial intelligence (AI) in personalized diabetes care. It addresses the limitations of traditional glucose monitoring and underscores the need for continuous, multi-analyte physiological surveillance. The manuscript evaluates multi-biofluid sensing platforms, specifically those utilizing interstitial fluid (ISF), sweat, saliva, tears, and urine. ISF, an extracellular medium and a plasma ultrafiltrate, exhibits low protein content, a property that reduces sensor biofouling. ISF glucose demonstrates a strong correlation with blood glucose (R² &gt; 0.95) and can achieve high analytical sensitivity and specificity in clinically validated systems; however, diffusion-based time lags of 5–10 min present a kinetic challenge. Consequently, AI correction is necessary to ensure real-time accuracy, which is often achieved through minimally invasive microneedle arrays. Sweat analysis allows for non-invasive, multi-parameter measurements. Nevertheless, challenges such as pH instability and analyte loss due to evaporation complicate this sensing approach. Therefore, microfluidic techniques are essential for maintaining sample stability. A primary finding indicates that clinically validated Continuous Glucose Monitoring (CGM) systems yield substantial improvements in glycemic control, increasing Time in Range (TIR) by 10–15% and reducing the incidence of hypoglycemic events by 30–40%. AI-based predictive algorithms can forecast glucose excursions 30–60 min in advance, exhibiting an accuracy exceeding 94%. Key barriers to implementation include sensor calibration challenges, algorithmic bias, and significant healthcare equity issues. Future research should prioritize the development of multi-analyte implantable devices, leverage federated learning frameworks, and incorporate additional biomarkers to deliver continuous, multi-analyte, skin-conformal monitoring.</p><h3>Graphical Abstract</h3><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":647,"journal":{"name":"Journal of Materials Science: Materials in Medicine","volume":"37 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13437651/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Science: Materials in Medicine","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10856-026-07070-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This review examines the convergence of wearable biosensors and artificial intelligence (AI) in personalized diabetes care. It addresses the limitations of traditional glucose monitoring and underscores the need for continuous, multi-analyte physiological surveillance. The manuscript evaluates multi-biofluid sensing platforms, specifically those utilizing interstitial fluid (ISF), sweat, saliva, tears, and urine. ISF, an extracellular medium and a plasma ultrafiltrate, exhibits low protein content, a property that reduces sensor biofouling. ISF glucose demonstrates a strong correlation with blood glucose (R² > 0.95) and can achieve high analytical sensitivity and specificity in clinically validated systems; however, diffusion-based time lags of 5–10 min present a kinetic challenge. Consequently, AI correction is necessary to ensure real-time accuracy, which is often achieved through minimally invasive microneedle arrays. Sweat analysis allows for non-invasive, multi-parameter measurements. Nevertheless, challenges such as pH instability and analyte loss due to evaporation complicate this sensing approach. Therefore, microfluidic techniques are essential for maintaining sample stability. A primary finding indicates that clinically validated Continuous Glucose Monitoring (CGM) systems yield substantial improvements in glycemic control, increasing Time in Range (TIR) by 10–15% and reducing the incidence of hypoglycemic events by 30–40%. AI-based predictive algorithms can forecast glucose excursions 30–60 min in advance, exhibiting an accuracy exceeding 94%. Key barriers to implementation include sensor calibration challenges, algorithmic bias, and significant healthcare equity issues. Future research should prioritize the development of multi-analyte implantable devices, leverage federated learning frameworks, and incorporate additional biomarkers to deliver continuous, multi-analyte, skin-conformal monitoring.

Graphical Abstract

用于糖尿病监测和个性化护理的可穿戴多分析物生物传感器的纳米结构电极材料和柔性衬底工程:综述。
本文综述了可穿戴生物传感器和人工智能(AI)在个性化糖尿病护理中的融合。它解决了传统血糖监测的局限性,并强调了连续、多分析物生理监测的必要性。该论文评估了多种生物流体传感平台,特别是那些利用间质液(ISF)、汗液、唾液、眼泪和尿液的平台。ISF是一种细胞外介质和等离子体超滤液,具有低蛋白质含量,这一特性可以减少传感器的生物污染。ISF葡萄糖与血糖有很强的相关性(R²> 0.95),在临床验证的系统中具有很高的分析敏感性和特异性;然而,基于扩散的5-10分钟的时间滞后带来了动力学挑战。因此,人工智能校正是必要的,以确保实时精度,这通常是通过微创微针阵列来实现的。汗液分析允许非侵入性,多参数测量。然而,诸如pH不稳定和蒸发导致的分析物损失等挑战使这种传感方法复杂化。因此,微流体技术对于保持样品稳定性至关重要。一项初步研究表明,临床验证的连续血糖监测(CGM)系统在血糖控制方面取得了实质性的改善,将范围内时间(TIR)提高了10-15%,将低血糖事件的发生率降低了30-40%。基于人工智能的预测算法可以提前30-60分钟预测葡萄糖漂移,准确率超过94%。实现的主要障碍包括传感器校准挑战、算法偏差和重大的医疗公平问题。未来的研究应优先开发多分析物植入式设备,利用联邦学习框架,并结合其他生物标志物来提供连续的、多分析物的、皮肤适形监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Materials Science: Materials in Medicine
Journal of Materials Science: Materials in Medicine 工程技术-材料科学:生物材料
CiteScore
8.00
自引率
0.00%
发文量
73
审稿时长
3.5 months
期刊介绍: The Journal of Materials Science: Materials in Medicine publishes refereed papers providing significant progress in the application of biomaterials and tissue engineering constructs as medical or dental implants, prostheses and devices. Coverage spans a wide range of topics from basic science to clinical applications, around the theme of materials in medicine and dentistry. The central element is the development of synthetic and natural materials used in orthopaedic, maxillofacial, cardiovascular, neurological, ophthalmic and dental applications. Special biomedical topics include biomaterial synthesis and characterisation, biocompatibility studies, nanomedicine, tissue engineering constructs and cell substrates, regenerative medicine, computer modelling and other advanced experimental methodologies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书