Dimensional Assessment and Measurement Uncertainty Estimation of H13 Tool Steel Specimen Fabricated using Metal Fused Filament Fabrication (M-FFF)

IF 1.4 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION
MAPAN Pub Date : 2026-03-28 DOI:10.1007/s12647-026-00918-1
Vandana Jain, Harish Kumar, Girija Moona
{"title":"Dimensional Assessment and Measurement Uncertainty Estimation of H13 Tool Steel Specimen Fabricated using Metal Fused Filament Fabrication (M-FFF)","authors":"Vandana Jain,&nbsp;Harish Kumar,&nbsp;Girija Moona","doi":"10.1007/s12647-026-00918-1","DOIUrl":null,"url":null,"abstract":"<div><p>This work investigates the dimensional accuracy, shrinkage behavior, and dimensional measurement uncertainty of sintered H13 tool steel specimen manufactured through Metal Fused Filament Fabrication (M-FFF), implemented in this study through a Markforged Metal X (Atomic diffusion additive manufacturing based) system. Linear, circular, and angular dimensions were characterized through a high-accuracy Coordinate Measuring Machine (CMM), and uncertainty budgets were prepared in accordance with the Law of Propagation of Uncertainty (LPU) method. Results indicate anisotropic shrinkage with the X–Y plane undergoing more shrinkage (17.0–20.0%) than the Z-direction (15.0–15.5%), due to filament packing density, layer stacking limitations, and thermal gradients during debinding and sintering. Typical uncertainty evaluation for linear dimensions of the sintered samples demonstrated the maximum combined standard uncertainty of ± 14.008 µm, whereas the expanded uncertainty computed was ± 38.8 µm (at a coverage factor <i>k</i> = 2.77, corresponding to the confidence level of 95% for a Gaussian distribution). Angular dimensions showed the highest deviations up to 0.23° and, maximum combined uncertainty of ± 363 Arc seconds and the expanded uncertainty of ± 1006 Arc seconds (at a coverage factor <i>k</i> = 2.77, corresponding to the confidence level of 95% for a Gaussian distribution). The investigation points to the significant effect of anisotropic shrinkage on dimensional deviation and underpins the need for sound uncertainty quantification to separate the true process-induced deformation from measurement randomness. For high-precision applications such as molds and cutting tools, post-processing or enhanced process control is recommended to ensure compliance with dimensional and angular tolerance requirements.</p></div>","PeriodicalId":689,"journal":{"name":"MAPAN","volume":"41 2","pages":"629 - 646"},"PeriodicalIF":1.4000,"publicationDate":"2026-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MAPAN","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s12647-026-00918-1","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

This work investigates the dimensional accuracy, shrinkage behavior, and dimensional measurement uncertainty of sintered H13 tool steel specimen manufactured through Metal Fused Filament Fabrication (M-FFF), implemented in this study through a Markforged Metal X (Atomic diffusion additive manufacturing based) system. Linear, circular, and angular dimensions were characterized through a high-accuracy Coordinate Measuring Machine (CMM), and uncertainty budgets were prepared in accordance with the Law of Propagation of Uncertainty (LPU) method. Results indicate anisotropic shrinkage with the X–Y plane undergoing more shrinkage (17.0–20.0%) than the Z-direction (15.0–15.5%), due to filament packing density, layer stacking limitations, and thermal gradients during debinding and sintering. Typical uncertainty evaluation for linear dimensions of the sintered samples demonstrated the maximum combined standard uncertainty of ± 14.008 µm, whereas the expanded uncertainty computed was ± 38.8 µm (at a coverage factor k = 2.77, corresponding to the confidence level of 95% for a Gaussian distribution). Angular dimensions showed the highest deviations up to 0.23° and, maximum combined uncertainty of ± 363 Arc seconds and the expanded uncertainty of ± 1006 Arc seconds (at a coverage factor k = 2.77, corresponding to the confidence level of 95% for a Gaussian distribution). The investigation points to the significant effect of anisotropic shrinkage on dimensional deviation and underpins the need for sound uncertainty quantification to separate the true process-induced deformation from measurement randomness. For high-precision applications such as molds and cutting tools, post-processing or enhanced process control is recommended to ensure compliance with dimensional and angular tolerance requirements.

金属熔丝法(M-FFF)加工H13工具钢试样的尺寸评定及测量不确定度评定
这项工作研究了通过金属熔丝制造(M-FFF)制造的烧结H13工具钢试样的尺寸精度、收缩行为和尺寸测量不确定度,在这项研究中通过Markforged Metal X(基于原子扩散增材制造)系统实现。通过高精度三坐标测量机(CMM)对直线、圆和角尺寸进行表征,并根据不确定性传播定律(LPU)方法编制不确定性预算。结果表明,由于长丝堆积密度、层堆积限制以及脱粘和烧结过程中的热梯度,X-Y方向的各向异性收缩率(17.0 ~ 20.0%)大于z方向(15.0 ~ 15.5%)。烧结样品线性尺寸的典型不确定度评估显示,最大联合标准不确定度为±14.008µm,而计算的扩展不确定度为±38.8µm(在覆盖因子k = 2.77时,对应于高斯分布的95%置信水平)。角尺寸的最大偏差可达0.23°,最大综合不确定度为±363弧秒,扩展不确定度为±1006弧秒(覆盖因子k = 2.77,对应于高斯分布的95%置信水平)。该研究指出,各向异性收缩对尺寸偏差有显著影响,并支持对声音不确定性量化的需要,以将真正的过程引起的变形与测量随机性分开。对于模具和切削工具等高精度应用,建议进行后处理或增强过程控制,以确保符合尺寸和角度公差要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
MAPAN
MAPAN 工程技术-物理:应用
CiteScore
2.30
自引率
20.00%
发文量
91
审稿时长
3 months
期刊介绍: MAPAN-Journal Metrology Society of India is a quarterly publication. It is exclusively devoted to Metrology (Scientific, Industrial or Legal). It has been fulfilling an important need of Metrologists and particularly of quality practitioners by publishing exclusive articles on scientific, industrial and legal metrology. The journal publishes research communication or technical articles of current interest in measurement science; original work, tutorial or survey papers in any metrology related area; reviews and analytical studies in metrology; case studies on reliability, uncertainty in measurements; and reports and results of intercomparison and proficiency testing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书