Super-resolution deep learning reconstruction achieves low-dose high-resolution imaging in pediatric cardiac computed tomography.

IF 2.5 3区 医学 Q2 PEDIATRICS
Pediatric Radiology Pub Date : 2026-09-01 Epub Date: 2026-05-28 DOI:10.1007/s00247-026-06668-1
Haruka Obinata, Kiyohiro Takigiku, Kosuke Yonehara, Yuma Shibuya, Yohei Akazawa, Kohta Takei, Daisuke Miyazawa, Taro Sakashita
{"title":"Super-resolution deep learning reconstruction achieves low-dose high-resolution imaging in pediatric cardiac computed tomography.","authors":"Haruka Obinata, Kiyohiro Takigiku, Kosuke Yonehara, Yuma Shibuya, Yohei Akazawa, Kohta Takei, Daisuke Miyazawa, Taro Sakashita","doi":"10.1007/s00247-026-06668-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac computed tomography (CT) is widely utilized in pediatric cardiology, but minimizing radiation exposure is essential. Recently, super-resolution deep learning reconstruction (SR-DLR) has emerged as a potential advancement over conventional deep learning reconstruction (C-DLR).</p><p><strong>Objective: </strong>To evaluate the potential of SR-DLR for further radiation dose reduction in pediatric cardiac CT through a comparison with C-DLR.</p><p><strong>Materials and methods: </strong>The phantom-based study assessed noise power spectrum and spatial resolution. For the clinical study, we compared nine C-DLR images (conventional radiation dose) and 11 SR-DLR images (lower radiation dose). Evaluation metrics included noise levels, contrast-to-noise ratio, and edge rise distance and edge rise slope.</p><p><strong>Results: </strong>In the phantom-based study, SR-DLR (250 mA) displayed equivalent noise characteristics as C-DLR (800 mA) while achieving superior spatial resolution. In clinical images, preliminary comparisons within the high-dose group revealed that SR-DLR significantly outperformed C-DLR in spatial resolution metrics, specifically edge rise distance and edge rise slope (P<0.001). Furthermore, despite the lower radiation dose used for SR-DLR than for C-DLR (volume CT dose index, 4.25±0.54 mGy vs. 13.3±6.43 mGy), there were no significant differences in noise, contrast resolution, and spatial resolution between the groups.</p><p><strong>Conclusion: </strong>SR-DLR maintains non-inferior image quality compared with C-DLR even at reduced radiation doses. These findings substantiate the potential for further dose reduction in pediatric cardiac CT without compromising image quality.</p>","PeriodicalId":19755,"journal":{"name":"Pediatric Radiology","volume":" ","pages":"2238-2248"},"PeriodicalIF":2.5000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00247-026-06668-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cardiac computed tomography (CT) is widely utilized in pediatric cardiology, but minimizing radiation exposure is essential. Recently, super-resolution deep learning reconstruction (SR-DLR) has emerged as a potential advancement over conventional deep learning reconstruction (C-DLR).

Objective: To evaluate the potential of SR-DLR for further radiation dose reduction in pediatric cardiac CT through a comparison with C-DLR.

Materials and methods: The phantom-based study assessed noise power spectrum and spatial resolution. For the clinical study, we compared nine C-DLR images (conventional radiation dose) and 11 SR-DLR images (lower radiation dose). Evaluation metrics included noise levels, contrast-to-noise ratio, and edge rise distance and edge rise slope.

Results: In the phantom-based study, SR-DLR (250 mA) displayed equivalent noise characteristics as C-DLR (800 mA) while achieving superior spatial resolution. In clinical images, preliminary comparisons within the high-dose group revealed that SR-DLR significantly outperformed C-DLR in spatial resolution metrics, specifically edge rise distance and edge rise slope (P<0.001). Furthermore, despite the lower radiation dose used for SR-DLR than for C-DLR (volume CT dose index, 4.25±0.54 mGy vs. 13.3±6.43 mGy), there were no significant differences in noise, contrast resolution, and spatial resolution between the groups.

Conclusion: SR-DLR maintains non-inferior image quality compared with C-DLR even at reduced radiation doses. These findings substantiate the potential for further dose reduction in pediatric cardiac CT without compromising image quality.

超分辨率深度学习重建在儿童心脏计算机断层扫描中实现低剂量高分辨率成像。
背景:心脏计算机断层扫描(CT)广泛应用于儿科心脏病学,但尽量减少辐射暴露是必要的。最近,超分辨率深度学习重建(SR-DLR)已经成为传统深度学习重建(C-DLR)的潜在进步。目的:通过与C-DLR的比较,评价SR-DLR在儿童心脏CT进一步降低辐射剂量的潜力。材料和方法:基于模态的研究评估了噪声功率谱和空间分辨率。在临床研究中,我们比较了9张C-DLR图像(常规辐射剂量)和11张SR-DLR图像(低辐射剂量)。评价指标包括噪声水平、噪声对比比、边缘上升距离和边缘上升斜率。结果:在基于模态的研究中,SR-DLR (250 mA)表现出与C-DLR (800 mA)相当的噪声特性,同时获得了更好的空间分辨率。在临床图像中,高剂量组的初步比较显示,SR-DLR在空间分辨率指标上明显优于C-DLR,特别是边缘上升距离和边缘上升斜率(结论:即使在降低辐射剂量下,SR-DLR与C-DLR相比仍保持不逊色的图像质量。这些发现证实了在不影响图像质量的情况下进一步减少儿童心脏CT剂量的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Radiology
Pediatric Radiology 医学-核医学
CiteScore
4.40
自引率
17.40%
发文量
300
审稿时长
3-6 weeks
期刊介绍: Official Journal of the European Society of Pediatric Radiology, the Society for Pediatric Radiology and the Asian and Oceanic Society for Pediatric Radiology Pediatric Radiology informs its readers of new findings and progress in all areas of pediatric imaging and in related fields. This is achieved by a blend of original papers, complemented by reviews that set out the present state of knowledge in a particular area of the specialty or summarize specific topics in which discussion has led to clear conclusions. Advances in technology, methodology, apparatus and auxiliary equipment are presented, and modifications of standard techniques are described. Manuscripts submitted for publication must contain a statement to the effect that all human studies have been reviewed by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in an appropriate version of the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书