Thomas Codant, Pauline Renou, Georgios Papaioannou, Jean-Benoît Thambo, Carine Boulon, Damien Barcat, Joël Constans, Loubna Dari
{"title":"Detection of Patent Foramen Ovale: Transcranial Doppler and Echocardiography Are Not Equivalent to Define a Large Shunt","authors":"Thomas Codant, Pauline Renou, Georgios Papaioannou, Jean-Benoît Thambo, Carine Boulon, Damien Barcat, Joël Constans, Loubna Dari","doi":"10.1002/jcu.70278","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The decision to close patent foramen ovale (PFO) depends on the size of PFO, the coexistence of interatrial septum aneurysm, and the importance of right-to-left shunt assessed by the number of bubbles on transcranial Doppler (TCD) and echocardiography after saline or glucose injection. The interventional threshold for the number of bubbles is considered to be the same for trans-thoracic and trans-esophageal echocardiography (TTE and TEE) and TCD. Our objective was to study whether the same thresholds can be used for TCD and echocardiography.</p>\n </section>\n \n <section>\n \n <h3> Patients and Methods</h3>\n \n <p>In this comparative, observational study, we modeled a linear relationship between the number of bubbles on TCD and echocardiography, which suggests a different threshold between TCD and TTE/TEE.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>We found a systematic difference between TTE/TEE and TCD for the number of bubbles in the same patient. From linear regression, we found the following equation: TCD<sub>Estimate</sub> = (7.2 (95% CI: −2.36–16.8) + (2.67 (95% CI: 1.85–3.49, <i>p</i> < 0.001)) × <i>TTE/TEE</i>).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Different thresholds for the decision to close a PFO should be used for both techniques: 20 bubbles for echocardiography and 60 bubbles for TCD.</p>\n </section>\n </div>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":"54 8","pages":"1836-1841"},"PeriodicalIF":1.3000,"publicationDate":"2026-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jcu.70278","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The decision to close patent foramen ovale (PFO) depends on the size of PFO, the coexistence of interatrial septum aneurysm, and the importance of right-to-left shunt assessed by the number of bubbles on transcranial Doppler (TCD) and echocardiography after saline or glucose injection. The interventional threshold for the number of bubbles is considered to be the same for trans-thoracic and trans-esophageal echocardiography (TTE and TEE) and TCD. Our objective was to study whether the same thresholds can be used for TCD and echocardiography.
Patients and Methods
In this comparative, observational study, we modeled a linear relationship between the number of bubbles on TCD and echocardiography, which suggests a different threshold between TCD and TTE/TEE.
Results
We found a systematic difference between TTE/TEE and TCD for the number of bubbles in the same patient. From linear regression, we found the following equation: TCDEstimate = (7.2 (95% CI: −2.36–16.8) + (2.67 (95% CI: 1.85–3.49, p < 0.001)) × TTE/TEE).
Conclusion
Different thresholds for the decision to close a PFO should be used for both techniques: 20 bubbles for echocardiography and 60 bubbles for TCD.
期刊介绍:
The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography.
The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents.
JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.